Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Anal Bioanal Chem ; 413(13): 3487-3492, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33763747

RESUMO

Two 3D stochastic microsensors based on single and multi-walled carbon nanotubes modified with 2,3,7,8,12,13,17,18-octaethyl-21H,23H-porphine manganese (III) chloride were proposed for the molecular recognition and determination of heregulin-α, in whole blood samples and tumour brain tissues. The proposed 3D stochastic sensors had limits of determinations of 102 fg mL-1 and high sensitivities. The linear concentration ranges of the two 3D stochastic microsensors covered the healthy people as well as the patients confirmed with brain cancer. Determination of heregulin-α was done in whole blood and tissue samples using the screening method based on the proposed 3D stochastic microsensors as well as using the ELISA method; very good correlations were obtained between the two methods proving that the proposed method can be used in screening tests of whole blood and tumoural tissue samples for molecular recognition and determination of heregulin-α.


Assuntos
Neuregulina-1/análise , Processos Estocásticos , Técnicas Biossensoriais , Neoplasias Encefálicas/química , Ensaio de Imunoadsorção Enzimática , Humanos , Limite de Detecção , Neurotransmissores/análise
3.
Mikrochim Acta ; 187(11): 611, 2020 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-33063228

RESUMO

A gold nanoparticle/graphene quantum dots (AuNP/GQD) nanozyme-modified screen-printed carbon electrode (SPCE) was developed for fast and ultrasensitive determination of quercetin by square-wave voltammetry. The nanosensing device was inserted in miniaturized equipment. Under the optimal experimental conditions, a good linear relationship between oxidation peak current and concentration of quercetin within a very wide range of 1.0 × 10-10 to 1.0 × 10-3 mol L-1 was obtained, with a very low limit of detection of 3.3 × 10-11 mol L-1. To prove the performance of the method, the reproducibility was evaluated and the RSD values were lower than 5.3% and 5.1% for the intra-day and inter-day measurements, respectively. The method was applied to the sensitive determination of quercetin in human plasma droplets with recovery rates of 92.6 to 101.7%.Graphical abstract.


Assuntos
Técnicas Eletroquímicas/métodos , Nanopartículas Metálicas/química , Pontos Quânticos/química , Quercetina/sangue , Carbono/química , Catálise , Técnicas Eletroquímicas/instrumentação , Eletrodos , Ouro/química , Grafite/química , Humanos , Limite de Detecção , Oxirredução , Quercetina/química , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...