Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Radiat Oncol ; 9(7): 101525, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38948918

RESUMO

Purpose: For lung stereotactic body radiation therapy, 4-dimensional computed tomography is often used to delineate target volumes, whereas organs at risk (OARs) are typically outlined on either average intensity projection (AIP) or midventilation (MidV = 30% phase) images. AIP has been widely adopted as it represents a true average, but image blurring often precludes accurate contouring of critical structures such as central airways. Here, we compare AIP versus MidV planning for centrally located tumors via respiratory motion-inclusive (RMI) plans to better evaluate dose delivered throughout the breathing cycle. Methods and Materials: Independently contoured and optimized AIP and MidV plans were created for 16 treatments and rigidly copied to each of the 10 breathing phase-specific computed tomography image sets. Resulting dose distributions were deformably registered back to the MidV image set (used as reference because of clearer depiction of anatomy compared with motion-blurred AIP) and averaged to create RMI plans. Doses to central OARs were compared between plans. Results: Mean absolute dose differences were low for all comparisons (range, 0.01-2.87 Gy); however, individual plans exhibited differences >20 Gy. Dose differences >5 Gy were observed most often for plan comparisons involving AIP-based plans (MidV vs AIP 23, AIP RMI vs AIP 12, MidV RMI vs AIP RMI 7, and MidV RMI vs MidV 8 times). Inclusion of respiratory motion reduced large dose differences. Standard OAR thresholds were exceeded up to 5 times for each plan comparison scenario and always involved proximal bronchial tree D4 cc tolerance dose. AIP-based contours were larger by, on average, 3% to 15%. Conclusions: Large dose differences were observed when plans with AIP-based contours were compared with MidV-based contours, indicating that observed dose differences were likely due to contoured volume differences rather than the effect of motion. Because of blurring with AIP images, MidV RMI-based planning may offer a more accurate method to determine dose to critical OARs in the presence of respiratory motion.

2.
J Clin Med ; 11(9)2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-35566712

RESUMO

This study investigates plan quality generated by an MR-Linac (MRL) treatment planning system (TPS) for 5-fraction stereotactic body radiation therapy (SBRT) of primary pancreatic cancer (PCa). In addition, an isotoxic dose escalation was investigated with the MRL TPS based on stereotactic MR-guided adaptive radiation therapy (SMART) trial constraints. A clinical workflow was developed for adaptive and non-adaptive treatments with the MRL, on which a time-driven activity-based costing (TDABC) analysis was performed to quantify clinical efficacy. Fifteen PCa patients previously treated with a conventional Linac were retrospectively re-planned for this study. Three plans were generated for each patient using the original prescription dose (PD) and organ at risk (OAR) constraints (Plan 1), following SMART trial's OAR constraints but with the original PD (Plan 2), starting with Plan 2, following an isotoxic dose escalation strategy where the dose was escalated until any one of the SMART trial's OAR constraints reached its limit (Plan 3). Conformity index (CI) and the ratio of the 50% isodose volume to PTV (R50%) conformity metrics were calculated for all 45 MRL plans, in addition to standard dose-volume indices. Forty-five MRL plans were created which met their respective dosimetric criteria described above. For Plan 1, the MRL TPS successfully achieved equivalent or lower OAR doses while maintaining the prescribed PTV coverage for the 15 plans. A maximum dose to the small bowel was reduced on average by 4.97 Gy (range: 1.11-10.58 Gy). For Plan 2, the MRL TPS successfully met all SMART trial OAR constraints while maintaining equivalent PTV coverage. For Plan 3, the MRL TPS was able to escalate the prescription dose from the original 25-33 Gy by, on average, 36 Gy (range: 15-70 Gy), and dose to the PTV was successfully escalated to at least 50 Gy for all 15 plans. These achievements were made possible, in part, due to the omission of the ITV afforded by the MRL's real-time target tracking technology and sharper dose penumbra due to its unique dual-focus MLC design. The 0.35T MRL TPS can generate plans that are equivalent to conventional Linac-based plans for SBRT of PCa. Through analyzing Plan 2 and 3 strategies, and due to the real-time target localization capabilities of the MRL system, increased OAR sparing and/or target dose escalation are possible.

3.
Cardiooncology ; 6: 6, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32626602

RESUMO

BACKGROUND AND PURPOSE: Radiotherapy has been associated with late dose-dependent cardiovascular toxicity. In this cross-sectional pilot study, radiation dose distributions were correlated with areas of localized and diffuse myocardial fibrosis as measured by novel cardiac MRI (CMR) sequences including late gadolinium enhancement (LGE) and T1 mapping with the goal to identify early markers of myocardial damage. MATERIALS AND METHODS: Twenty-eight patients with chest tumors including lung, breast, esophagus, and lymphoma underwent CMR per study protocol on average 46.4 months (range 1.7-344.5) after radiotherapy. Patients without pretreatment cardiac history were included if the volume of heart receiving 5 Gy or more was at least 10% (V5Gy ≥ 10%). The association of LGE with cardiac dosimetric factors, clinical factors (e.g., tumor type, smoking history, BMI), and T1 values was analyzed. RESULTS: Cardiac maximum (Dmax) and mean dose (Dmean) equivalent to doses delivered in 2 Gy fractions (EQD2) were on average 50.9 Gy (range 6.2-108.0) and 8.2 Gy (range 1.0-35.7), respectively, compared to 60.8 Gy (40.8-108.0) and 6.8 Gy (1.8-21.8) among the 9 patients with LGE. Doses were not different between patients with and without LGE (p = 0.16 and 0.56, respectively). The average T1 value of the left ventricle myocardium was 1009 ms (range 933-1117). No significant correlation was seen for heart Dmax and Dmean and T1 values (p = 0.14 and 0.58, respectively). In addition, no significant association between clinical factors and the development of LGE was identified. CONCLUSIONS: No relation between cardiac doses, the presence of LGE or T1 values was observed. Further study is needed to determine the benefit of CMR for detecting radiotherapy-related myocardial fibrosis.

4.
J Neurosurg ; 122(5): 1127-30, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25415068

RESUMO

OBJECT When intracranial tumors invade the overlying skull, gross resection typically includes removal of the involved bone. Methods used to repair the resulting structural defect in the cranium include artificial prostheses, allogeneic bone grafts, and autoclaving the autologous graft. The authors have previously reported a case involving high-dose extracorporeal ionizing radiation to treat the tumorous calvaria intraoperatively, followed by reimplantation of the treated bone flap. In this paper the authors report the long-term follow-up of that case, as well as results of using extracorporeal irradiation of tumorous calvaria (EITC) for an additional 20 patients treated similarly. METHODS The decision to undergo EITC was typically anticipated preoperatively, but determined intraoperatively, if upon inspection the bone flap was invaded by tumor. The bone flap was then delivered to the radiation oncology department, where a total dose of 120 Gy was delivered, using a clinical linear accelerator, over a period of approximately 15 minutes. After the intracranial tumor resection was completed, the irradiated craniotomy bone flap was reimplanted and the wound was closed in a standard fashion. A retrospective review of patients who had undergone EITC was performed for evidence of calvarial tumor recurrence or other complications. RESULTS Since the originally reported case, 20 additional patients have received EITC during craniotomy for invasive tumors. Eighteen (86%) of 21 patients were diagnosed with meningioma: 12 (67%) with WHO Grade I, 5 (28%) with WHO Grade II, and 1 with WHO Grade III (6%). The remaining 3 patients presented with dural-based B-cell lymphoma with extensive adjacent bone invasion (n = 2) and metastatic adenocarcinoma of the lung (n = 1). Follow-up of the 21 patients ranged from 1 to 132 months, with a mean of 41 months and a median of 23 months. No patients have experienced tumor recurrence, infection associated with the treated calvaria, or evidence of bone flap resorption. CONCLUSIONS Calvaria reconstructions represent an important component in structural and cosmetic outcome following craniectomy for tumorous bone. The authors' long-term experience with EITC has been excellent with no local tumor recurrence or complications. Therefore, EITC represents an excellent and efficient option for cranial reconstruction in such patients.


Assuntos
Craniotomia , Neoplasias Cranianas/radioterapia , Neoplasias Cranianas/cirurgia , Retalhos Cirúrgicos , Adulto , Idoso , Neoplasias Encefálicas/patologia , Terapia Combinada , Feminino , Seguimentos , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Radioterapia/métodos , Reimplante , Estudos Retrospectivos , Neoplasias Cranianas/patologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...