Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasonics ; 52(3): 447-55, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22112792

RESUMO

Passive localization of an object from its emission can be based on time difference of arrival or phase shift measurements for different receiver groups in sensor arrays. The accuracy of the localization primarily depends on accurate time and/or phase measurements. The frequency of the emission and the number and arrangement of the receivers mainly effect the resolution of the emitter localization. In this paper optimal receiver positions for passive localization methods are proposed, resulting in a maximal resolution for the emitter location estimate. The optimization is done by analyzing the uncertainty of the emitted signal, including its frequency. The technique has been developed specifically for ultrasound signals obtained from omnidirectional transducers, although the results apply for other application using passive localization techniques.


Assuntos
Ultrassom/métodos , Transdutores
2.
Biotech Histochem ; 86(2): 115-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20163280

RESUMO

The ability to observe samples undergoing controlled fluid flow under the microscope is important for studying biochemical processes and motion dynamics. We describe here a simple method to achieve this using coverslips shaped using a fiber scribe. Testing showed good directional flow control within the test range of 0-1 ml/min flow rate and an ability to sustain a flow rate up to approximately 1 ml/min. Testing with a sealed T-channel coverslip demonstrated the ability to construct fluid network branches with this scheme. We also demonstrated the usefulness of this procedure in motion dynamic studies of Dunaliella algae swimming under fluid flow.


Assuntos
Clorófitas , Microscopia/instrumentação , Microscopia/métodos , Clorófitas/citologia , Clorófitas/fisiologia , Cinética , Modelos Biológicos , Movimento (Física)
3.
Ultrasonics ; 50(2): 247-57, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19837446

RESUMO

Acoustic radiation forces have often been used for the manipulation of large amounts of micrometer sized suspended particles. The nature of acoustic standing wave fields is such that they are present throughout the whole fluidic volume; this means they are well suited to such operations, with all suspended particles reacting at the same time upon exposure. Here, this simultaneous positioning capability is exploited to pre-align particles along the centerline of channels, so that they can successively be removed by means of an external tool for further analysis. This permits a certain degree of automation in single particle manipulation processes to be achieved as initial identification of particles' location is no longer necessary, rather predetermined. Two research fields in which applications are found have been identified. First, the manipulation of copolymer beads and cells using a microgripper is presented. Then, sample preparation for crystallographic analysis by positioning crystals into a loop using acoustic manipulation and a laminar flow will be presented.

4.
J Acoust Soc Am ; 122(5): 2587-93, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18189550

RESUMO

A theoretical approach is described which predicts the fields of acoustic radiators with a predefined surface topography. This is achieved by dividing the surface of the source into small elements, each of which is oriented parallel to the tangent to the surface at that point. The result is an improved modeling performance, in that it is more efficient and requires far fewer elements compared to other numerical approaches using parallel elements. Theoretical predictions are compared to experimental results from curved electrostatic radiators, to demonstrate that the approach has promise.

5.
Ultrasonics ; 43(4): 211-7, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15567195

RESUMO

This paper describes the use of non-contact ultrasound for the evaluation of concrete. Micromachined capacitance transducers are used to transmit ultrasonic longitudinal chirp signals through concrete samples using air as the coupling medium, and a pulse compression technique is then employed for measurement of time of flight through the sample. The effect on the ultrasonic wave speed of storing concrete samples, made with the same water/cement ratio, at different humidity levels is investigated. It is shown that there is a correlation between humidity and speed of sound, allowing a correction factor for humidity to be derived. A strong positive linear correlation between aggregate content and speed of sound was then observed; there was no obvious correlation between compressive strength and speed of sound. The results from the non-contact system are compared with that from a contact system, and conclusions drawn concerning coupling of energy into the samples.


Assuntos
Umidade , Ultrassom , Ar , Materiais de Construção
6.
Ultrasonics ; 43(3): 183-95, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15556653

RESUMO

This paper presents an investigation into the fields radiated into air by ultrasonic phased arrays under transient excitation. In particular, it includes a theoretical prediction of spatial variations in amplitude throughout the both the near-field and far-field of such arrays. The approach has been used to predict the result of phasing to produce a focus in air, which can be seen to be particularly effective in the near-field of the array. Interesting features are observed, which are then described in terms of the performance of both individual elements and the resulting array. It is shown how some elements of design can be used to improve performance in focussing. The predictions are compared to the results of experiments in air using electrostatic arrays, where good focussing could be achieved provided the appropriate design principles were followed. The approach has been developed specifically for use in air, but the results would also hold for modelling in certain medical arrays where a focussing requirement might be needed close to the array itself.

7.
Ultrasonics ; 42(1-9): 447-52, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15047327

RESUMO

This paper presents results from a theoretical model of the ultrasonic fields radiated by a 3x3 assembly of capacitive micromachined ultrasonic transducer (cMUT) sources on the same silicon substrate. These predictions have, for the first time, been compared directly to the fields measured experimentally using a scanned miniature detector. This work indicates that there is minimal cross-coupling between source elements, and demonstrates that it is possible to predict successfully the field characteristics of various geometries of such cMUT elements, with a view to the development of future imaging systems.

8.
Ultrasonics ; 42(1-9): 859-64, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15047397

RESUMO

Polymer-membrane capacitive ultrasonic linear and 2-D arrays have been fabricated for use in air-coupled imaging. By using arrays as receivers, there is a possibility of much faster imaging as the need for physically moving the receiver to scan a sample can be replaced by electronic multiplexing. In order to utilise this, a through-thickness air-coupled image of a composite plate has been made using a 2-D array as a receiver and a comparatively large planar source in air. This was made possible by the use of a chirp drive signal and cross-correlation on the measured waveform. Larger 2-D arrays with an increased number of elements have been simulated using a small scanned single receiver, and excellent imaging potential demonstrated. In addition two array receivers have been used in conjunction with two methods of post-processing, SAFT and ellipse crossing, to locate objects accurately.

9.
J Immunol ; 164(1): 419-26, 2000 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-10605038

RESUMO

Experimental autoimmune encephalomyelitis induced by myelin oligodendrocyte glycoprotein (MOG) in C57BL/6 (H-2b) mice is characterized by early (day 12) acute paralysis, followed by a sustained chronic clinical course that gradually stabilizes. Extensive inflammation and demyelination coincide with clinical signs of disease. To identify the mechanisms of these processes, individual proinflammatory and anti-inflammatory cytokines and chemokines were studied. Sensitive single-cell assays were utilized to determine the cellular origin and kinetics of cytokine production in the CNS. Immunization with MOG35-55 peptide resulted in priming of both Th1 (lymphotoxin, IFN-gamma, and TNF-alpha) and Th2 (IL-4) cells in the spleen. However, only Th1 cells were apparent in the CNS. CD4 T cells that produced IFN-gamma or TNF-alpha were present in the CNS by day 7 after immunization with MOG35-55, peaked at day 20, and then waned. TNF-alpha was also produced in the CNS by Mac-1+ cells. On days 7 and 10 after immunization, the TNF-alpha-producing Mac1+ cells were predominantly microglia. By day 14, a switch occurred in that the Mac1+ TNF-alpha-producing cells had the phenotype of infiltrating macrophages. RANTES, IFN-inducible protein 10 (IP-10), and monocyte chemotactic protein 1 chemokine mRNA were detected in the CNS by day 8 after immunization. The early presence of monocyte chemotactic protein 1 (MCP-1) in the CNS provides a mechanism for the recruitment of macrophages. These data implicate TNF-alpha production by a continuum of T cells, microglia, and macrophages at various times during the course of disease. The importance of Th1 cytokines is highlighted, with little evidence for a role of Th2 cytokines.


Assuntos
Sistema Nervoso Central/imunologia , Sistema Nervoso Central/metabolismo , Citocinas/biossíntese , Encefalomielite Autoimune Experimental/imunologia , Glicoproteína Associada a Mielina/imunologia , Sequência de Aminoácidos , Animais , Sistema Nervoso Central/citologia , Quimiocinas/biossíntese , Encefalomielite Autoimune Experimental/etiologia , Encefalomielite Autoimune Experimental/metabolismo , Feminino , Imunofenotipagem , Mediadores da Inflamação/metabolismo , Injeções Subcutâneas , Interferon gama/biossíntese , Interferon gama/metabolismo , Cinética , Ativação Linfocitária , Macrófagos/imunologia , Macrófagos/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Microglia/imunologia , Microglia/metabolismo , Dados de Sequência Molecular , Proteínas da Mielina , Glicoproteína Associada a Mielina/administração & dosagem , Glicoproteína Mielina-Oligodendrócito , Baço/citologia , Baço/imunologia , Baço/metabolismo , Células Th1/imunologia , Células Th1/metabolismo , Células Th2/imunologia , Células Th2/metabolismo , Fator de Necrose Tumoral alfa/biossíntese , Fator de Necrose Tumoral alfa/metabolismo
10.
J Synchrotron Radiat ; 3(Pt 5): 220-4, 1996 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16702682

RESUMO

A high-pressure low-temperature cell has been developed for in-situ diffraction studies of carbon dioxide and propane gas hydrate crystallization. The design and implementation of the cell, which can operate up to 3.5 MPa and down to 253 K, are described. Using synchrotron energy-dispersive X-ray diffraction, the first growth of the hydrate crystals from solution has been successfully observed. The lattice parameters of the hydrate crystals were found to be 11.927 (2) and 17.196 (2) A, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...