Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Front Dent ; 20: 25, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37701654

RESUMO

Objectives: This study aimed to investigate the impact of three different bleaching protocols on tooth discoloration caused by tea. Materials and Methods: Forty extracted sound premolars were cleaned, disinfected, and their initial color parameters were measured (T1). The teeth were then immersed in boiled tea solution for 24 hours, and their color was measured again (T2). The samples were divided into four groups of 10 teeth each. Group A was treated with an in-office bleaching gel followed by 30 seconds of light curing. Groups B, C, and D were respectively treated with 0.24M oxalic acid followed by bleaching gel, 5.25% sodium hypochlorite followed by bleaching gel, and a combination of 0.24M oxalic acid, 5.25% sodium hypochlorite, and bleaching gel. The color was measured once more after the interventions (T3). Data were analyzed using two-way repeated measures ANOVA, paired sample t-test, and Tukey's test. Results: The mean color change (∆E2) between T2 and T3 was significantly higher in group D compared to group A (P<0.05). However, there was no significant difference in color change between groups A, B, and C. Additionally, there was no significant difference in color change between groups B, C, and D. The groups also showed significant differences in ∆L (P=0.007), with the only significant difference found between groups B and C (P=0.001). Conclusion: The combined use of sodium hypochlorite and oxalic acid followed by in-office bleaching gel is more effective than bleaching alone in correcting tooth discoloration caused by tea. This protocol can further reduce yellow coloration.

2.
Braz. j. oral sci ; 21: e225263, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1369650

RESUMO

Aim: This study was fulfilled to evaluate the flexural strength, micro-hardness, and release of two fluoride ions of bioactive restorative materials (Cention N and Activa Bioactive), a resin modified glass ionomer (Fuji II LC), and a resin composite (Filtek z250). Methods: Forty samples from four restorative materials (Activa Bioactive, Fuji II LC, Cention N, and Filtek Z250) were provided according to the current standards of ISO 4049/2000 guide lines. Subsequently, the samples were stored for 24 hours and 6 months in artificial saliva, and successively, flexural strength and micro-hardness of the samples were measured. For each studied groups the pH was decreased from 6.8 to 4 in storage solution. The rate of changes in fluoride ion release was measured after three different storage periods of 24 hours, 48 hours, and 6 months in distilled water, according to the previous studies' method. Two-way ANOVA, One-way ANOVA, Tukey HSD Pair wise comparisons, and independent t-tests were used to analyze data (α= 0.05). Results: The highest flexural strength and surface micro-hardness after 24 hours and also after 6 month were observed for Cention N(p<0.001).Flexural strength of all samples stored for 6 months was significantly lower than the samples stored for 24 hours(p<0.001). The accumulative amount of the released fluoride ion in RMGI, after six-month storage period in distilled water was considerably higher (p<0.001) than 24 hours and 48 hours storage. The amount of fluoride ion release with increasing acidity of the environment (from pH 6.8 to 4) in Fuji II LC glass ionomer was higher than the bioactive materials (p<0.05). Conclusion: The flexural strength of RMGI was increased after storage against the Activa Bioactive,Cention N and Z250 composite. Storage of restorative materials in artificial saliva leads to a significant reduction in micro hardness. The behavior and amount of released fluoride ions in these restorative materials, which are stored in an acidic environment, were dependent on the type of restorative material


Assuntos
Saliva Artificial , Teste de Materiais , Materiais Dentários , Fenômenos Físicos
3.
Braz. j. oral sci ; 20: e210525, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1253928

RESUMO

Aim: Recent reports indicate that deproteinization of acid-etched dentin surface can extend penetration depth of adhesive agents. The main goal of the present research was to investigate the deproteinization effect of Nd:YAG and diode 940 lasers on acid-etched dentin and microleakage grade in class V composite restorations. Methods: 36 extracted human premolar teeth were selected to make standard buccal and lingual class V cavities. These samples were randomly split into three sub-groups: 1.Control group, in which composite was applied for restoration after etch and bonding process without deproteinization; 2.Nd:YAG laser group, in which the teeth were deproteinized with Nd:YAG laser after etching and painting internal surfaces of cavities with Van Geison stain and then composite restorations applied just as control group; 3.Diode laser group, in which the process was similar to Nd:YAG laser group, but instead, diode 940 laser was irradiated. The teeth were bisected into two equal longitudinal buccal and lingual halves. Marginal microleakage of samples was scored by using a stereomicroscope. Kruskal- Wallis, Mann-Whitney U and Fisher's statistical tests were employed for analysis of the obtained data. Results: A significant reduction in marginal microleakage was observed for both groups treated with laser (Nd:YAG and diode 940)compared to control (p=0.001 & p=0.047). There was no significant difference in marginal microleakage between Nd:YAG laser and diode 940groups (P = 0.333). Conclusion: Nd:YAG and diode 940 laser deproteinization of acid-etched dentin decreased the marginal microleakage of in-vitro class V resin composite restorations


Assuntos
Humanos , Condicionamento Ácido do Dente , Adesivos Dentinários , Infiltração Dentária , Lasers
4.
Int J Dent ; 2021: 5572569, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34040643

RESUMO

AIM: Several new bioactive compounds were recently introduced to the market with favorable ion release, tooth remineralization, and alkalizing potential. This study sought to compare the phosphate ion release and alkalizing potential of three bioactive materials in comparison with composite resin. METHODS: Thirty-six discs (2 × 6 mm) were fabricated from Fuji II LC resin modified glass ionomer (RMGI), Activa BioActive, Cention N, and Z250 composite in plastic molds. The specimens were stored in distilled water for 24 and 48 h and 6 months. Half of the specimens were used to assess the phosphate ion release while the other half were used to assess the alkalizing potential 1 h after pH drop from 6.8 to 4. Phosphate ion release was quantified by a spectrophotometer while the pH value was measured by a pH meter. Data were analyzed using two-way ANOVA, one-way ANOVA, and Tukey's HSD test (for pairwise comparisons) at 0.05 level of significance. RESULTS: At 24 h, the maximum phosphate ion release in distilled water occurred in the Fuji II LC group followed by Cention N, Activa BioActive, and Z250. At 6 months, Cention N followed by Activa BioActive showed higher phosphate ion release than Fuji II LC and Z250. No significant difference was noted between Activa BioActive and Cention N at any time point. All materials, except for Z250, increased the pH of the environment. Fuji II LC had maximum alkalizing effect at all time points followed by Cention N and Activa BioActive. CONCLUSION: Use of bioactive compounds is a promising method to ensure phosphate ion release, and can have a positive effect on tooth remineralization over time. Also, bioactive compounds can alkalize an acidic environment.

5.
Eur J Dent ; 12(1): 105-110, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29657533

RESUMO

OBJECTIVE: In this study, we compared the effects of 0.12% chlorhexidine (CHX) and nano zinc oxide (NZO) on the microshear bond strength of dentin with a fifth-generation adhesive after acid etching. MATERIALS AND METHODS: Forty molar teeth were randomly divided into four main groups based on dentin surface treatment technique (a) control (single bond 2); (b) NZO; (c) CHX; and (d) NZO + CHX. In each group, half of the samples underwent thermocycling, with no thermocycling in the other half. Then, failure mode was evaluated under a stereomicroscope. Statistical analysis was performed using t-test, two-way ANOVA, and Chi-squared test. RESULTS: The mean microshear bond strength of the groups without thermocycling was more than that of the groups with thermocycling, but there were no statistically significant differences between the groups with and without thermocycling in pair-wise comparisons. CONCLUSION: Pretreatment with NZO and CHX separately and simultaneously had no effect on the microshear bond strength of a fifth-generation adhesive.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...