1.
Sleep ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700932

RESUMO

STUDY OBJECTIVES: Evaluate wrist-placed accelerometry predicted heartrate compared to electrocardiogram (ECG) heartrate in children during sleep. METHODS: Children (n=82, 61% male, 43.9% Black) wore a wrist-placed Apple Watch Series 7 (AWS7) and ActiGraph GT9X during a polysomnogram. 3-Axis accelerometry data was extracted from AWS7 and the GT9X. Accelerometry heartrate estimates were derived from jerk (the rate of acceleration change), computed using the peak magnitude frequency in short time Fourier Transforms of Hilbert transformed jerk computed from acceleration magnitude. Heartrates from ECG traces were estimated from R-R intervals using R-pulse detection. Lin's Concordance Correlation Coefficient (CCC), mean absolute error (MAE) and mean absolute percent error (MAPE) assessed agreement with ECG estimated heartrate. Secondary analyses explored agreement by polysomnography sleep stage and a signal quality metric. RESULTS: The developed scripts are available on Github. For the GT9X, CCC was poor at -0.11 and MAE and MAPE were high at 16.8 (SD=14.2) beats/minute and 20.4% (SD=18.5%). For AWS7, CCC was moderate at 0.61 while MAE and MAPE were lower at 6.4 (SD=9.9) beats/minute and 7.3% (SD=10.3%). Accelerometry estimated heartrate for AWS7 was more closely related to ECG heartrate during N2, N3 and REM sleep than lights on, wake, and N1 and when signal quality was high. These patterns were not evident for the GT9X. CONCLUSIONS: Raw accelerometry data extracted from AWS7, but not the GT9X, can be used to estimate heartrate in children while they sleep. Future work is needed to explore the sources (i.e., hardware, software, etc.) of the GT9X's poor performance.

2.
PLoS One ; 19(3): e0286898, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38551940

RESUMO

The purpose of this study was to evaluate the reliability and validity of the raw accelerometry output from research-grade and consumer wearable devices compared to accelerations produced by a mechanical shaker table. Raw accelerometry data from a total of 40 devices (i.e., n = 10 ActiGraph wGT3X-BT, n = 10 Apple Watch Series 7, n = 10 Garmin Vivoactive 4S, and n = 10 Fitbit Sense) were compared to reference accelerations produced by an orbital shaker table at speeds ranging from 0.6 Hz (4.4 milligravity-mg) to 3.2 Hz (124.7mg). Two-way random effects absolute intraclass correlation coefficients (ICC) tested inter-device reliability. Pearson product moment, Lin's concordance correlation coefficient (CCC), absolute error, mean bias, and equivalence testing were calculated to assess the validity between the raw estimates from the devices and the reference metric. Estimates from Apple, ActiGraph, Garmin, and Fitbit were reliable, with ICCs = 0.99, 0.97, 0.88, and 0.88, respectively. Estimates from ActiGraph, Apple, and Fitbit devices exhibited excellent concordance with the reference CCCs = 0.88, 0.83, and 0.85, respectively, while estimates from Garmin exhibited moderate concordance CCC = 0.59 based on the mean aggregation method. ActiGraph, Apple, and Fitbit produced similar absolute errors = 16.9mg, 21.6mg, and 22.0mg, respectively, while Garmin produced higher absolute error = 32.5mg compared to the reference. ActiGraph produced the lowest mean bias 0.0mg (95%CI = -40.0, 41.0). Equivalence testing revealed raw accelerometry data from all devices were not statistically significantly within the equivalence bounds of the shaker speed. Findings from this study provide evidence that raw accelerometry data from Apple, Garmin, and Fitbit devices can be used to reliably estimate movement; however, no estimates were statistically significantly equivalent to the reference. Future studies could explore device-agnostic and harmonization methods for estimating physical activity using the raw accelerometry signals from the consumer wearables studied herein.


Assuntos
Acelerometria , Dispositivos Eletrônicos Vestíveis , Reprodutibilidade dos Testes , Exercício Físico , Monitores de Aptidão Física
3.
Med Sci Sports Exerc ; 56(2): 370-379, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37707503

RESUMO

INTRODUCTION: This study examined the potential of a device agnostic approach for predicting physical activity from consumer wearable accelerometry compared with a research-grade accelerometry. METHODS: Seventy-five 5- to 12-year-olds (58% male, 63% White) participated in a 60-min protocol. Children wore wrist-placed consumer wearables (Apple Watch Series 7 and Garmin Vivoactive 4) and a research-grade device (ActiGraph GT9X) concurrently with an indirect calorimeter (COSMED K5). Activity intensities (i.e., inactive, light, moderate-to-vigorous physical activity) were estimated via indirect calorimetry (criterion), and the Hildebrand thresholds were applied to the raw accelerometer data from the consumer wearables and research-grade device. Epoch-by-epoch (e.g., weighted sensitivity, specificity) and discrepancy (e.g., mean bias, absolute error) analyses evaluated agreement between accelerometry-derived and criterion estimates. Equivalence testing evaluated the equivalence of estimates produced by the consumer wearables and ActiGraph. RESULTS: Estimates produced by the raw accelerometry data from ActiGraph, Apple, and Garmin produced similar criterion agreement with weighted sensitivity = 68.2% (95% confidence interval (CI), 67.1%-69.3%), 73.0% (95% CI, 71.8%-74.3%), and 66.6% (95% CI, 65.7%-67.5%), respectively, and weighted specificity = 84.4% (95% CI, 83.6%-85.2%), 82.0% (95% CI, 80.6%-83.4%), and 75.3% (95% CI, 74.7%-75.9%), respectively. Apple Watch produced the lowest mean bias (inactive, -4.0 ± 4.5; light activity, 2.1 ± 4.0) and absolute error (inactive, 4.9 ± 3.4; light activity, 3.6 ± 2.7) for inactive and light physical activity minutes. For moderate-to-vigorous physical activity, ActiGraph produced the lowest mean bias (1.0 ± 2.9) and absolute error (2.8 ± 2.4). No ActiGraph and consumer wearable device estimates were statistically significantly equivalent. CONCLUSIONS: Raw accelerometry estimated inactive and light activity from wrist-placed consumer wearables performed similarly to, if not better than, a research-grade device, when compared with indirect calorimetry. This proof-of-concept study highlights the potential of device-agnostic methods for quantifying physical activity intensity via consumer wearables.


Assuntos
Acelerometria , Dispositivos Eletrônicos Vestíveis , Criança , Humanos , Masculino , Feminino , Punho , Exercício Físico , Comportamento Sedentário
4.
Sleep Health ; 9(4): 417-429, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37391280

RESUMO

GOAL AND AIMS: Evaluate the performance of a sleep scoring algorithm applied to raw accelerometry data collected from research-grade and consumer wearable actigraphy devices against polysomnography. FOCUS METHOD/TECHNOLOGY: Automatic sleep/wake classification using the Sadeh algorithm applied to raw accelerometry data from ActiGraph GT9X Link, Apple Watch Series 7, and Garmin Vivoactive 4. REFERENCE METHOD/TECHNOLOGY: Standard manual PSG sleep scoring. SAMPLE: Fifty children with disrupted sleep (M = 8.5 years, range = 5-12 years, 42% Black, 64% male). DESIGN: Participants underwent to single night lab polysomnography while wearing ActiGraph, Apple, and Garmin devices. CORE ANALYTICS: Discrepancy and epoch-by-epoch analyses for sleep/wake classification (devices vs. polysomnography). ADDITIONAL ANALYTICS AND EXPLORATORY ANALYSES: Equivalence testing for sleep/wake classification (research-grade actigraphy vs. commercial devices). CORE OUTCOMES: Compared to polysomnography, accuracy, sensitivity, and specificity were 85.5, 87.4, and 76.8, respectively, for Actigraph; 83.7, 85.2, and 75.8, respectively, for Garmin; and 84.6, 86.2, and 77.2, respectively, for Apple. The magnitude and trend of bias for total sleep time, sleep efficiency, sleep onset latency, and wake after sleep were similar between the research and consumer wearable devices. IMPORTANT ADDITIONAL OUTCOMES: Equivalence testing indicated that total sleep time and sleep efficiency estimates from the research and consumer wearable devices were statistically significantly equivalent. CORE CONCLUSION: This study demonstrates that raw acceleration data from consumer wearable devices has the potential to be harnessed to predict sleep in children. While further work is needed, this strategy could overcome current limitations related to proprietary algorithms for predicting sleep in consumer wearable devices.


Assuntos
Acelerometria , Sono , Humanos , Masculino , Criança , Feminino , Reprodutibilidade dos Testes , Polissonografia , Actigrafia