1.
Clin Biochem ; 49(1-2): 100-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26500003

RESUMO

OBJECTIVES: The primary objective of this study was to evaluate potential interference of Trinder-based chemistry assays by N-acetylcysteine (NAC). A secondary objective was to look for evidence of interference in patients treated with NAC for acetaminophen (APAP) overdose. DESIGN AND METHODS: Dilutions of NAC in plasma were tested for interference using the following Roche Diagnostics Trinder-based assays on a cobas 8000 system: enzymatic creatinine (Cr), cholesterol (CHOL), high-density lipoprotein cholesterol (HDL-C), triglycerides (TRIG), and uric acid (UA). Two non-Trinder Roche assays - urea nitrogen (BUN) and glucose (GLUC) - were tested as controls. Sekisui N-geneous® low-density lipoprotein cholesterol (LDL-C) reagent was also evaluated. Retrospective chart review of APAP overdose cases over 49months was conducted to look for differences in plasma Cr before and after intravenous (IV) NAC administration. RESULTS: NAC concentrations (shown in parentheses) that caused ≥10% inhibition for individual assays were (in order of sensitivity to interference): TRIG (570mg/L)>CHOL (740mg/L)≈Cr (790mg/L)>UA (1100mg/L)>HDL-C (1760mg/L)>LDL-C (2900mg/L). Neither BUN nor GLUC achieved significant inhibition up to 10,000mg/L NAC. Evidence for relatively minor inhibition of Cr was observed in patients after NAC administration. CONCLUSIONS: NAC inhibition of the assays investigated typically occurs at concentrations higher than expected during IV and oral NAC therapy.


Assuntos
Acetaminofen/intoxicação , Acetilcisteína/uso terapêutico , Compostos Férricos/química , Acetilcisteína/sangue , Humanos , Intoxicação/tratamento farmacológico , Estudos Retrospectivos
2.
Springerplus ; 4: 760, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26682113

RESUMO

The measurement of free immunoglobulin light chains is typically performed on serum; however, the use of alternative specimen types has potential benefits. Using the Freelite™ kappa and lambda free light chains assay on a Roche Diagnostics cobas 8000 c502 analyzer, we compared three specimen types (serum, EDTA-plasma and lithium heparin plasma separator gel-plasma) on 100 patients. Using Deming regression and eliminating outliers (limiting data to light chain concentrations below 400 mg/L), the three specimen types showed comparable results for kappa light chain concentration, lambda light chain concentration, and kappa/lambda ratio with slopes close to 1.0 and y-intercepts close to zero. EDTA-plasma showed slightly more positive bias relative to serum than lithium heparin. Analysis using EDTA-plasma and lithium heparin plasma showed comparable linearity, precision, and temperature stability. A single sample showing hook effect (not in the comparison set) gave comparable results using either plasma specimen type. For the Freelite™ kappa and lambda free light chains assay, both EDTA-plasma or lithium heparin-plasma can serve as acceptable substitutes for serum, at least for the Roche cobas 8000 analyzer.

3.
BMC Clin Pathol ; 15: 11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26052250

RESUMO

BACKGROUND: Clinical laboratories frequently receive orders to perform additional tests on existing specimens ('add-ons'). Previous studies have examined add-on ordering patterns over short periods of time. The objective of this study was to analyze add-on ordering patterns over an extended time period. We also analyzed the impact of a robotic specimen archival/retrieval system on add-on testing procedure and manual effort. METHODS: In this retrospective study at an academic medical center, electronic health records from were searched to obtain all add-on orders that were placed in the time period of May 2, 2009 to December 31, 2014. RESULTS: During the time period of retrospective study, 880,359 add-on tests were ordered on 96,244 different patients. Add-on testing comprised 3.3 % of total test volumes. There were 443,411 unique ordering instances, leading to an average of 1.99 add-on tests per instance. Some patients had multiple episodes of add-on test orders at different points in time, leading to an average of 9.15 add-on tests per patient. The majority of add-on orders were for chemistry tests (78.8 % of total add-ons) with the next most frequent being hematology and coagulation tests (11.2 % of total add-ons). Inpatient orders accounted for 66.8 % of total add-on orders, while the emergency department and outpatient clinics had 14.8 % and 18.4 % of total add-on orders, respectively. The majority of add-ons were placed within 8 hours (87.3 %) and nearly all by 24 hours (96.8 %). Nearly 100 % of add-on orders within the emergency department were placed within 8 hours. The introduction of a robotic specimen archival/retrieval unit saved an average of 2.75 minutes of laboratory staff manual time per unique add-on order. This translates to 24.1 hours/day less manual effort in dealing with add-on orders. CONCLUSION: Our study reflects the previous literature in showing that add-on orders significantly impact the workload of the clinical laboratory. The majority of add-on orders are clinical chemistry tests, and most add-on orders occur within 24 hours of original specimen collection. Robotic specimen archival/retrieval units can reduce manual effort in the clinical laboratory associated with add-on orders.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...