Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Condens Matter ; 36(21)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38364273

RESUMO

Passive solid-state radiation detectors, based on the visible photoluminescence (PL) of radiation-induced colour centres in optically transparent lithium fluoride (LiF), polycrystalline thin films are under investigation for proton beam advanced diagnostics. After proton exposure, the latent images stored in LiF as local formations of stable F2and F3+aggregate defects, are directly read with a fluorescence microscope under illumination in the blue spectral range. Adopting a suitable irradiation geometry, the energy density that protons deposit in the material can be recorded as a spatial distribution of these light-emitting defects, from which a luminous replica of the proton Bragg curve can be thereafter extracted and analysed to reconstruct the proton beam energy spectrum. Their peculiar properties, such as wide dynamic range and linearity of the spectrally-integrated PL response vs. dose, make the investigation of two-dimensional LiF film radiation detectors grown on several types of substrate highly attractive. Here, the case of a LiF thin film thermally evaporated on a silica substrate, irradiated at grazing incidence with a 35 MeV proton beam, is investigated and reported for the first time. A comparison of the measured photoluminescent Bragg curve with Monte Carlo simulations demonstrates that the Bragg peak in the film is located at the very same position that would be expected in the underlying silica substrate rather than in LiF. The film packing density is shown not to have a significant effect on the peak depth, while even small nonzero grazing angle of the impinging proton beam is able to significantly modify the shape of the Bragg curve. These findings are ascribed to the effects of multiple Coulomb scattering in both the film and the substrate and are interesting for proton beam diagnostics and dosimetry.

2.
Rev Sci Instrum ; 92(11): 113304, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852547

RESUMO

In a medical accelerator, real-time monitoring systems of the beam and dose delivered to the patient are mandatory. In this work, we present a compact current profile detector that has been designed and tested in the framework of the TOP-IMPLART (Intensity Modulated Proton Linear Accelerator for RadioTerapy) project. This project foresees the realization of a proton linear accelerator, currently under construction at ENEA Frascati, for proton therapy applications. The linac produces a pulsed proton beam with 3 µs duration at 50 Hz repetition rate with a pulse current between 0.5 and 50 µA. A large dynamic range and spatial constraints make the use of usual noninterceptive beam diagnostics unfeasible. Therefore, the use of a beam current monitor based on a passive RF cavity working in the TM010 mode has been proposed. This paper reports the electromagnetic design of the device guided by a simplified analytical model. A prototype of such a device has been realized, characterized, and tested on the linac with a 35 MeV beam varying the beam current. The test results in air and in vacuum, together with the signal detection systems used, are presented.


Assuntos
Terapia com Prótons , Humanos , Aceleradores de Partículas , Prótons
3.
Radiat Prot Dosimetry ; 186(1): 113-118, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31141142

RESUMO

In the framework of the Italian TOP-IMPLART project (Regione Lazio), ENEA-Frascati, ISS and IFO are developing and constructing the first proton linear accelerator based on an actively scanned beam for tumor radiotherapy with final energy of 150 MeV. An important feature of this accelerator is modularity: an exploitable beam can be delivered at any stage of its construction, which allows for immediate characterization and virtually continuous improvement of its performance. Currently, a sequence of 3 GHz accelerating modules combined with a commercial injector operating at 425 MHz delivers protons up to 35 MeV. Several dosimetry systems were used to obtain preliminary characteristics of the 35-MeV beam in terms of stability and homogeneity. Short-term stability and homogeneity better than 3% and 2.6%, respectively, were demonstrated; for stability an improvement with respect to the respective value obtained for the previous 27 MeV beam.


Assuntos
Aceleradores de Partículas/instrumentação , Prótons , Radiometria/instrumentação , Radiometria/métodos , Desenho de Equipamento , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...