1.
Med Phys ; 48(4): 1646-1660, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33220073

RESUMO

PURPOSE: Spatial distortions in magnetic resonance imaging (MRI) are mainly caused by inhomogeneities of the static magnetic field, nonlinearities in the applied gradients, and tissue-specific magnetic susceptibility variations. These factors may significantly alter the geometrical accuracy of the reconstructed MR image, thus questioning the reliability of MRI for guidance in image-guided radiation therapy. In this work, we quantified MRI spatial distortions and created a quantitative model where different sources of distortions can be separated. The generated model was then integrated into a four-dimensional (4D) computational phantom for simulation studies in MRI-guided radiation therapy at extra-cranial sites. METHODS: A geometrical spatial distortion phantom was designed in four modules embedding laser-cut PMMA grids, providing 3520 landmarks in a field of view of (345 × 260 × 480) mm3 . The construction accuracy of the phantom was verified experimentally. Two fast MRI sequences for extra-cranial imaging at 1.5 T were investigated, considering axial slices acquired with online distortion correction, in order to mimic practical use in MRI-guided radiotherapy. Distortions were separated into their sources by acquisition of images with gradient polarity reversal and dedicated susceptibility calculations. Such a separation yielded a quantitative spatial distortion model to be used for MR imaging simulations. Finally, the obtained spatial distortion model was embedded into an anthropomorphic 4D computational phantom, providing registered virtual CT/MR images where spatial distortions in MRI acquisition can be simulated. RESULTS: The manufacturing accuracy of the geometrical distortion phantom was quantified to be within 0.2 mm in the grid planes and 0.5 mm in depth, including thickness variations and bending effects of individual grids. Residual spatial distortions after MRI distortion correction were strongly influenced by the applied correction mode, with larger effects in the trans-axial direction. In the axial plane, gradient nonlinearities caused the main distortions, with values up to 3 mm in a 1.5 T magnet, whereas static field and susceptibility effects were below 1 mm. The integration in the 4D anthropomorphic computational phantom highlighted that deformations can be severe in the region of the thoracic diaphragm, especially when using axial imaging with 2D distortion correction. Adaptation of the phantom based on patient-specific measurements was also verified, aiming at increased realism in the simulation. CONCLUSIONS: The implemented framework provides an integrated approach for MRI spatial distortion modeling, where different sources of distortion can be quantified in time-dependent geometries. The computational phantom represents a valuable platform to study motion management strategies in extra-cranial MRI-guided radiotherapy, where the effects of spatial distortions can be modeled on synthetic images in a virtual environment.


Assuntos
Radioterapia Guiada por Imagem , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
2.
Phys Med Biol ; 64(20): 205006, 2019 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-31519018

RESUMO

Magnetic-resonance linear-accelerator (MR-LINAC) systems integrating in-room magnetic-resonance-imaging (MRI) guidance are a currently emerging technology. Such systems address the need to provide frequent imaging at optimal soft-tissue contrast for treatment guidance. However, the use of MRI-guidance in radiotherapy should address imaging-related spatial distortions, which may hinder accurate geometrical characterization of the treatment site. Since spatial encoding relies on well-defined magnetic fields, accurate modeling of the magnetic field alterations due to [Formula: see text]-inhomogeneities, gradient nonlinearities, and susceptibilities is needed. In this work, the modeling of susceptibility induced distortions is considered. Dedicated susceptibility measurements are reported, aiming at extending the characterization of different tissues for MRI-guided extra-cranial radiotherapy applications. A digital 4D anthropomorphic phantom, providing time-resolved anatomical changes due to breathing, is exploited as reference anatomy to quantify spatial distortions due to variations in tissue susceptibility. Sub-millimeter values can be attributed to susceptibility-induced distortions, with maximum values up to 2.3 mm at a gradient strength of 5 mT m-1. Improvements in susceptibility simulation for extra-cranial sites are shown when including specifically the contributions from lung, liver and muscular tissues.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias de Tecidos Moles/radioterapia , Algoritmos , Animais , Fígado/efeitos da radiação , Pulmão/efeitos da radiação , Campos Magnéticos , Músculo Esquelético/efeitos da radiação , Aceleradores de Partículas , Respiração , Suínos
3.
Nature ; 561(7723): 374-377, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30232421

RESUMO

Photoemission spectroscopy is central to understanding the inner workings of condensed matter, from simple metals and semiconductors to complex materials such as Mott insulators and superconductors1. Most state-of-the-art knowledge about such solids stems from spectroscopic investigations, and use of subfemtosecond light pulses can provide a time-domain perspective. For example, attosecond (10-18 seconds) metrology allows electron wave packet creation, transport and scattering to be followed on atomic length scales and on attosecond timescales2-7. However, previous studies could not disclose the duration of these processes, because the arrival time of the photons was not known with attosecond precision. Here we show that this main source of ambiguity can be overcome by introducing the atomic chronoscope method, which references all measured timings to the moment of light-pulse arrival and therefore provides absolute timing of the processes under scrutiny. Our proof-of-principle experiment reveals that photoemission from the tungsten conduction band can proceed faster than previously anticipated. By contrast, the duration of electron emanation from core states is correctly described by semiclassical modelling. These findings highlight the necessity of treating the origin, initial excitation and transport of electrons in advanced modelling of the attosecond response of solids, and our absolute data provide a benchmark. Starting from a robustly characterized surface, we then extend attosecond spectroscopy towards isolating the emission properties of atomic adsorbates on surfaces and demonstrate that these act as photoemitters with instantaneous response. We also find that the tungsten core-electron timing remains unchanged by the adsorption of less than one monolayer of dielectric atoms, providing a starting point for the exploration of excitation and charge migration in technologically and biologically relevant adsorbate systems.

4.
Unfallchirurg ; 118(6): 549-63, 2015 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-26013391

RESUMO

The advantages that are inherent to the air ambulance service are shown in a reduction in mortality of critically ill or injured patients. The air ambulance service ensures quick and efficient medical care to a patient as well as the immediate transport of patients to a suitable hospital. In addition, primary air rescue has proved to be effective as a support for the standard ground-based ambulance services in some regions of Germany during the night. Under certain conditions, such as the strict adherence to established, practiced and coordinated procedures, air rescue at night does not have a significantly higher risk compared to operations in daytime. Particular requirements should be imposed for air rescue operations at night: a strict indication system for alerting, 4-man helicopter crews solely during the night as well as pilots (and copilots) with the correct qualifications and experience in dealing with night vision devices on a regular basis. Moreover, the helicopters need to be suitable and approved for night flying including cabin upgrades and the appropriate medical technology equipment. To increase the benefits of air rescue for specific diseases and injuries, a nationwide review of the processes is needed to further develop the primary air rescue service.


Assuntos
Resgate Aéreo/estatística & dados numéricos , Cuidados Críticos/estatística & dados numéricos , Trabalho de Resgate/estatística & dados numéricos , Fatores de Tempo , Alemanha/epidemiologia
5.
Nature ; 517(7534): 342-6, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25592539

RESUMO

The propagation and transport of electrons in crystals is a fundamental process pertaining to the functioning of most electronic devices. Microscopic theories describe this phenomenon as being based on the motion of Bloch wave packets. These wave packets are superpositions of individual Bloch states with the group velocity determined by the dispersion of the electronic band structure near the central wavevector in momentum space. This concept has been verified experimentally in artificial superlattices by the observation of Bloch oscillations--periodic oscillations of electrons in real and momentum space. Here we present a direct observation of electron wave packet motion in a real-space and real-time experiment, on length and time scales shorter than the Bloch oscillation amplitude and period. We show that attosecond metrology (1 as = 10(-18) seconds) now enables quantitative insight into weakly disturbed electron wave packet propagation on the atomic length scale without being hampered by scattering effects, which inevitably occur over macroscopic propagation length scales. We use sub-femtosecond (less than 10(-15) seconds) extreme-ultraviolet light pulses to launch photoelectron wave packets inside a tungsten crystal that is covered by magnesium films of varied, well-defined thicknesses of a few ångströms. Probing the moment of arrival of the wave packets at the surface with attosecond precision reveals free-electron-like, ballistic propagation behaviour inside the magnesium adlayer--constituting the semi-classical limit of Bloch wave packet motion. Real-time access to electron transport through atomic layers and interfaces promises unprecedented insight into phenomena that may enable the scaling of electronic and photonic circuits to atomic dimensions. In addition, this experiment allows us to determine the penetration depth of electrical fields at optical frequencies at solid interfaces on the atomic scale.

6.
Phys Rev Lett ; 109(8): 087401, 2012 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-23002773

RESUMO

We report on laser-assisted attosecond photoemission from single-crystalline magnesium. In strong contrast to the previously investigated transition metal tungsten, photoelectron wave packets originating from the localized core level and delocalized valence-band states are launched simultaneously from the solid within the experimental uncertainty of 20 as. This phenomenon is shown to be compatible with a heuristic model based on free-particle-like propagation of the electron wave packets generated inside the crystal by the attosecond excitation pulse and their subsequent interaction with the assisting laser field at the metal-vacuum interface.

7.
Rev Sci Instrum ; 82(6): 063104, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21721671

RESUMO

We describe an apparatus for attosecond photoelectron spectroscopy of solids and surfaces, which combines the generation of isolated attosecond extreme-ultraviolet (XUV) laser pulses by high harmonic generation in gases with time-resolved photoelectron detection and surface science techniques in an ultrahigh vacuum environment. This versatile setup provides isolated attosecond pulses with photon energies of up to 140 eV and few-cycle near infrared pulses for studying ultrafast electron dynamics in a large variety of surfaces and interfaces. The samples can be prepared and characterized on an atomic scale in a dedicated flexible surface science end station. The extensive possibilities offered by this apparatus are demonstrated by applying attosecond XUV pulses with a central photon energy of ∼125 eV in an attosecond streaking experiment of a xenon multilayer grown on a Re(0001) substrate.

8.
Phys Rev Lett ; 107(2): 027801, 2011 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-21797640

RESUMO

Femtosecond charge transfer (CT) dynamics in a series of self-assembled monolayers with an oligo(phenylenethynylene) and oligo(phenyl) backbone is addressed by resonant Auger spectroscopy using the core hole clock method. The characteristic CT times are found to depend strongly on the character of the molecular orbital (MO) which mediates the CT process. This demonstrates that the efficiency and rate of CT through molecular frameworks can be controlled by resonant injection of the charge carriers into specific MOs.

9.
Science ; 328(5986): 1658-62, 2010 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-20576884

RESUMO

Photoemission from atoms is assumed to occur instantly in response to incident radiation and provides the basis for setting the zero of time in clocking atomic-scale electron motion. We used attosecond metrology to reveal a delay of 21 +/- 5 attoseconds in the emission of electrons liberated from the 2p orbitals of neon atoms with respect to those released from the 2s orbital by the same 100-electron volt light pulse. Small differences in the timing of photoemission from different quantum states provide a probe for modeling many-electron dynamics. Theoretical models refined with the help of attosecond timing metrology may provide insight into electron correlations and allow the setting of the zero of time in atomic-scale chronoscopy with a precision of a few attoseconds.

10.
J Am Chem Soc ; 130(35): 11778-82, 2008 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-18693686

RESUMO

Self-assembly techniques allow for the fabrication of highly organized architectures with atomic-level precision. Here, we report on molecular-level scanning tunneling microscopy observations demonstrating the supramolecular engineering of complex, regular, and long-range ordered periodic networks on a surface atomic lattice using simple linear molecular bricks. The length variation of the employed de novo synthesized linear dicarbonitrile polyphenyl molecules translates to distinct changes of the bonding motifs that lead to hierarchic order phenomena and unexpected changes of the surface tessellations. The achieved 2D organic networks range from a close-packed chevron pattern via a rhombic network to a hitherto unobserved supramolecular chiral kagomé lattice.