Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Perfusion ; 34(1): 67-75, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30058944

RESUMO

INTRODUCTION: This experimental study compares myocardial function after prolonged arrest by St. Thomas' Hospital polarizing cardioplegic solution (esmolol, adenosine, Mg2+) with depolarizing (hyperkalaemic) St. Thomas' Hospital No 2, both administered as cold oxygenated blood cardioplegia. METHODS: Twenty anaesthetized pigs on tepid (34°C) cardiopulmonary bypass (CPB) were randomised to cardioplegic arrest for 120 min with antegrade, repeated, cold, oxygenated, polarizing (STH-POL) or depolarizing (STH-2) blood cardioplegia every 20 min. Cardiac function was evaluated at Baseline and 60, 150 and 240 min after weaning from CPB, using a pressure-conductance catheter and epicardial echocardiography. Regional tissue blood flow, cleaved caspase-3 activity and levels of malondialdehyde were evaluated in myocardial tissue samples. RESULTS: Preload recruitable stroke work (PRSW) was increased after polarizing compared to depolarizing cardioplegia 150 min after declamping (73.0±3.2 vs. 64.3±2.4 mmHg, p=0.047). Myocardial tissue blood flow rate was high in both groups compared to the Baseline levels and decreased significantly in the STH-POL group only, from 60 min to 150 min after declamping (p<0.005). Blood flow was significantly reduced in the STH-POL compared to the STH-2 group 240 min after declamping (p<0.05). Left ventricular mechanical efficiency, the ratio between total pressure-volume area and blood flow rate, gradually decreased after STH-2 cardioplegia and was significantly reduced compared to STH-POL cardioplegia after 150 and 240 min (p<0.05 for both). CONCLUSION: Myocardial protection for two hours of polarizing cardioplegic arrest with STH-POL in oxygenated blood is non-inferior compared to STH-2 blood cardioplegia. STH-POL cardioplegia alleviates the mismatch between myocardial function and perfusion after weaning from CPB.


Assuntos
Soluções Cardioplégicas/uso terapêutico , Ponte Cardiopulmonar/métodos , Parada Cardíaca Induzida/métodos , Disfunção Ventricular Esquerda/etiologia , Adenosina/efeitos adversos , Adenosina/uso terapêutico , Animais , Soluções Cardioplégicas/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Modelos Animais de Doenças , Parada Cardíaca Induzida/efeitos adversos , Magnésio/efeitos adversos , Magnésio/uso terapêutico , Potássio/efeitos adversos , Potássio/uso terapêutico , Propanolaminas/efeitos adversos , Propanolaminas/uso terapêutico , Suínos , Disfunção Ventricular Esquerda/fisiopatologia
2.
Eur J Cardiothorac Surg ; 52(1): 180-188, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28329148

RESUMO

OBJECTIVES: This study investigated whether the novel St. Thomas' Hospital polarizing cardioplegic solution (STH-POL) with esmolol/adenosine/magnesium offers improved myocardial protection by reducing demands for high-energy phosphates during cardiac arrest compared to the depolarizing St. Thomas' Hospital cardioplegic solution No 2 (STH-2). METHODS: Twenty anaesthetised pigs on tepid cardiopulmonary bypass were randomized to cardiac arrest for 60 min with antegrade freshly mixed, repeated, cold, oxygenated STH-POL or STH-2 blood cardioplegia every 20 min. Haemodynamic variables were continuously recorded. Left ventricular biopsies, snap-frozen in liquid nitrogen or fixed in glutaraldehyde, were obtained at Baseline, 58 min after cross-clamp and 20 and 180 min after weaning from bypass. Adenine nucleotides were evaluated by high-performance liquid chromatography, myocardial ultrastructure with morphometry. RESULTS: With STH-POL myocardial creatine phosphate was increased compared to STH-2 at 58 min of cross-clamp [59.9 ± 6.4 (SEM) vs 44.5 ± 7.4 nmol/mg protein; P < 0.025], and at 20 min after reperfusion (61.0 ± 6.7 vs 49.0 ± 5.5 nmol/mg protein; P < 0.05), ATP levels were increased at 20 min of reperfusion with STH-POL (35.4 ± 1.1 vs 32.4 ± 1.2 nmol/mg protein; P < 0.05). Mitochondrial surface-to-volume ratio was decreased with polarizing compared to depolarizing cardioplegia 20 min after reperfusion (6.74 ± 0.14 vs 7.46 ± 0.13 µm 2 /µm 3 ; P = 0.047). None of these differences were present at 180 min of reperfusion. From 150 min of reperfusion and onwards, cardiac index was increased with STH-POL; 4.8 ± 0.2 compared to 4.0 ± 0.2 l/min/m 2 ( P = 0.011) for STH-2 at 180 min. CONCLUSIONS: Polarizing STH-POL cardioplegia improved energy status compared to standard STH-2 depolarizing blood cardioplegia during cardioplegic arrest and early after reperfusion.


Assuntos
Soluções Cardioplégicas/farmacologia , Metabolismo Energético/fisiologia , Parada Cardíaca Induzida/métodos , Parada Cardíaca/metabolismo , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Miocárdio/metabolismo , Animais , Biópsia , Creatinina/metabolismo , Modelos Animais de Doenças , Feminino , Parada Cardíaca/complicações , Parada Cardíaca/patologia , Masculino , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/metabolismo , Miocárdio/ultraestrutura , Fosfocreatina/metabolismo , Curva ROC , Suínos
SELEÇÃO DE REFERÊNCIAS