Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Sci Rep ; 7(1): 15685, 2017 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-29170446

RESUMO

Our recent report detailing the health status of cloned sheep concluded that the animals had aged normally. This is in stark contrast to reports on Dolly (first animal cloned from adult cells) whose diagnoses of osteoarthritis (OA) at 5½ years of age led to considerable scientific concern and media debate over the possibility of early-onset age-related diseases in cloned animals. Our study included four 8-year old ewes derived from the cell line that gave rise to Dolly, yet none of our aged sheep showed clinical signs of OA, and they had radiographic evidence of only mild or, in one case, moderate OA. Given that the only formal record of OA in Dolly is a brief mention of a single joint in a conference abstract, this led us to question whether the original concerns about Dolly's OA were justified. As none of the original clinical or radiographic records were preserved, we undertook radiographic examination of the skeletons of Dolly and her contemporary clones. We report a prevalence and distribution of radiographic-OA similar to that observed in naturally conceived sheep, and our healthy aged cloned sheep. We conclude that the original concerns that cloning had caused early-onset OA in Dolly were unfounded.


Assuntos
Clonagem de Organismos/efeitos adversos , Osteoartrite/epidemiologia , Fatores Etários , Idade de Início , Animais , Restos Mortais/diagnóstico por imagem , Linhagem Celular , Clonagem de Organismos/métodos , Feminino , Osteoartrite/diagnóstico por imagem , Osteoartrite/genética , Prevalência , Ovinos , Esqueleto/diagnóstico por imagem
2.
J Small Anim Pract ; 57(2): 59-66, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27168486

RESUMO

OBJECTIVE: To systematically evaluate the evidence reporting the frequency and risk factors of meniscal injury in dogs with cranial cruciate ligament failure. STUDY DESIGN: Systematic literature review. MATERIALS AND METHODS: Research questions were defined. An electronic database search of PubMed and CAB Abstracts was performed during November 2013. Data were extracted for study participants, design, intervention, outcome measures and results. Studies were evaluated using a validated instrument for assessing methodological quality and assigned a quality index score. A level of evidence was then assigned to each study. RESULTS: Sixty-two studies were identified. The median quality index score was 14 out of a possible 26. Twenty-four studies were prospective case series, 37 retrospective case series and 1 animal research study. There were no class I or class II studies, 24 class III studies and 38 class IV studies. CLINICAL SIGNIFICANCE: Despite a large number of publications the quality of evidence was generally low. No one study or combination of studies provided high quality evidence to establish the true frequency or risk factors for meniscal injury in dogs with cranial cruciate ligament failure.

3.
J Small Anim Pract ; 57(4): 194-204, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27000649

RESUMO

OBJECTIVE: To systematically evaluate the evidence reporting the diagnosis and management of meniscal injury in dogs with cranial cruciate ligament failure. STUDY DESIGN: Systematic literature review. MATERIALS AND METHODS: Research questions relating to the accuracy of diagnostic techniques for meniscal injury and the effects of meniscal treatment were defined. An electronic database search of PubMed and CAB Abstracts was performed during March 2015. Data were extracted for study participants, design, intervention, outcome measures and results. Studies were evaluated using a validated instrument for assessing methodological quality and assigned a Quality Index score. A level of evidence was then assigned to each study. RESULTS: Eighty-nine studies were identified. The median Quality Index score was 14 out of a possible 26. Twenty-seven studies were prospective case series, 31 retrospective case series, 16 animal research and 15 cadaveric studies. There were no class I or class II studies, 27 class III and 62 class IV studies. CONCLUSIONS: Despite a large number of publications the quality of evidence was generally low. No one study or combination of studies provided high quality evidence to support one diagnostic or surgical intervention over another for meniscal injuries in dogs with cranial cruciate ligament failure.


Assuntos
Ligamento Cruzado Anterior/fisiopatologia , Doenças do Cão/epidemiologia , Menisco/lesões , Animais , Artroscopia/veterinária , Doenças do Cão/diagnóstico , Doenças do Cão/terapia , Cães , Imageamento por Ressonância Magnética/veterinária , Menisco/diagnóstico por imagem , Menisco/cirurgia , Prevalência
4.
Vet Comp Orthop Traumatol ; 28(6): 433-40, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26449348

RESUMO

OBJECTIVE: To compare the bending properties of String-of-Pearls® (SOP) and Limited Contact Dynamic Compression Plate® (LC-DCP) constructs in orthogonal bending directions. METHODS: 3.5 mm SOP and LC-DCP plates were fixed to a bone model simulating a comminuted tibial fracture. Specimens were non-destructively tested in both mediolateral and craniocaudal bending for 10 cycles. Bending stiffness and total angular deformation were compared using parametric analyses (p <0.05). RESULTS: For both constructs, stiffness was significantly less when bending moments were applied against the thickness of the plates (mediolateral bending) than against the width (craniocaudal bending). When compared to the mediolateral plane, bending constructs in the craniocaudal plane resulted in a 49% (SOP group) and 370% (LC-DCP group) increase in stiffness (p <0.001). Mediolateral bending stiffness was significantly greater in the SOP than the LC-DCP constructs. Conversely, in craniocaudal bending, SOP constructs stiffness was significantly less than that of the LC-DCP constructs. The differences between the two constructs in total angular deformation had an identical pattern of significance. CLINICAL SIGNIFICANCE: This study found that SOP showed less variability between the orthogonal bending directions than LC-DCP in a comminuted fracture model, and also described the bi-planar bending behaviour of both constructs. Although not exhibiting identical bending properties in both planes, SOP constructs had a more homogenous bending behaviour in orthogonal loading directions. The difference between the SOP with a circular cross sectional shape compared to the rectangular shape of standard plates is probably responsible for this difference.


Assuntos
Placas Ósseas/veterinária , Análise de Falha de Equipamento/métodos , Teste de Materiais , Teste de Materiais/métodos , Mecânica
5.
J Small Anim Pract ; 56(8): 510-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26052962

RESUMO

OBJECTIVES: To compare the mechanical properties of monofilament nylon leader and orthopaedic wire for median sternotomy closure in the dog. MATERIALS AND METHODS: Median sternotomy was performed in 14 canine cadaver sternums with the manubrium intact. The sternotomy was closed with either 80 lb monofilament nylon leader or 20G orthopaedic stainless steel wire in a peristernal figure of 8 pattern. Constructs were loaded in a servohydraulic material testing machine. Load at yield, maximum load, stiffness, displacement and mode of failure were compared between constructs subjected to a single cycle load to failure. RESULTS: No significant differences were found in load at yield, maximum load, stiffness or displacement between the monofilament nylon leader and the stainless steel wire constructs. No implant failure was evident in the stainless steel wire constructs. Four of the monofilament nylon leader constructs failed by pulling of the nylon through the crimp. CLINICAL SIGNIFICANCE: Monofilament nylon leader is mechanically comparable to stainless steel wire and potentially a suitable alternative for closure of median sternotomy in the dog.


Assuntos
Fios Ortopédicos/veterinária , Cães/cirurgia , Esternotomia/veterinária , Esterno/cirurgia , Animais , Fenômenos Biomecânicos , Cadáver , Teste de Materiais/veterinária
6.
Vet Comp Orthop Traumatol ; 26(6): 445-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24008374

RESUMO

OBJECTIVE: To compare complication rates and the outcomes of these complications after lateral plate fixation with figure-of-eight tension-band-wire and pin or lag screw fixation for arthrodesis of the calcaneoquartal joint, following non-traumatic disruption of the plantar tarsal ligament in dogs. METHODS: Data were collected retrospectively from five UK referral centres. Diplomate specialists and their residents performed all procedures. Referring veterinarians were contacted for long-term follow-up. RESULTS: Seventy-four procedures were undertaken in 61 dogs. There were 58 arthrodeses in the lateral plate group (Plate), nine in the pin and tension-band-wire group (Pin), and seven in the lag screw and tension-band wire-group (Screw). Compared to Plate (17%), further surgical intervention was required more frequently following Pin (56%, OR = 3.2) or Screw (43%, OR = 2.5) fixation. Clinical failure of arthrodesis occurred less frequently with Plate (5%) compared with Screw (43%, OR = 8.6) and Pin fixation (22%, OR = 4.4). Cases managed with external coaptation postoperatively were more likely to suffer from postoperative complications (OR = 2.2). CLINICAL SIGNIFICANCE: Lateral plating was associated with fewer postoperative complications than pin and tension-band-wire fixation for arthrodesis of the calcaneoquartal joint in dogs with non-traumatic disruption of the plantar tarsal ligament.


Assuntos
Artrodese/veterinária , Placas Ósseas/veterinária , Parafusos Ósseos/veterinária , Fios Ortopédicos/veterinária , Doenças do Cão/cirurgia , Animais , Artrodese/instrumentação , Artrodese/métodos , Cães , Feminino , Luxações Articulares/etiologia , Luxações Articulares/cirurgia , Luxações Articulares/veterinária , Ligamentos/patologia , Masculino , Complicações Pós-Operatórias/veterinária , Estudos Retrospectivos , Ruptura/complicações , Ruptura/veterinária , Articulações Tarsianas/patologia , Articulações Tarsianas/cirurgia
7.
Vet Comp Orthop Traumatol ; 24(3): 215-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21373715

RESUMO

OBJECTIVES: To determine observer agreement on radiographic evaluation of central tarsal bone (CTB) fractures and compare this with evaluation of the same fractures using computed tomography (CT). METHODS: Radiographs and CT scans were obtained of the right tarsi from limbs of Greyhounds euthanatized after sustaining severe CTB fracture during racing. Four observers described and classified each fracture. Inter- and intra-observer agreements were calculated. RESULTS: Inter-observer agreement was higher for assessment of fractures using CT. Several fractures assessed by radiography were misclassified as a less severe type. Intra-observer agreement for assessment and classification of CTB fractures via radiography versus CT was variable. Overall agreement among all four observers was higher for CT than radiography. Additionally, when identifying fractures of the adjacent tarsal bones, observer agreement was higher for CT than radiography. CLINICAL SIGNIFICANCE: Computed tomography improved observer ability to correctly evaluate CTB fracture and detect the degree of displacement and extent of any comminution. Identification of fractures of adjacent tarsal bones was also improved when tarsi were assessed using CT. These data suggest that treatment decisions based solely on radiographic assessment of CTB fractures may not produce the expected outcome.


Assuntos
Doenças do Cão/patologia , Cães/lesões , Fraturas Ósseas/veterinária , Membro Posterior/patologia , Animais , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/epidemiologia , Fraturas Ósseas/classificação , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/patologia , Membro Posterior/diagnóstico por imagem , Variações Dependentes do Observador , Estresse Mecânico , Tarso Animal/lesões , Tomografia Computadorizada por Raios X/veterinária
8.
Vet Comp Orthop Traumatol ; 22(6): 492-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19876528

RESUMO

OBJECTIVES: To describe a technique for treating Y-T humeral fractures using paired string of pearls (SOP) plates and to review the outcome in 13 cases. METHODS: A series of 13 consecutive Y-T humeral fractures, otherwise known as distal humeral dicondylar fractures, were treated according to a surgical protocol which involved combined medial and lateral surgical approaches, accurate reduction and fixation of the condylar fracture with a single transcondylar lag screw, and then re-alignment and fixation of the diaphyseal fracture using two SOP plates and screws. RESULTS: Functional outcome was recorded as excellent in 10 dogs, good in two and poor in one. Six of the 13 patients were working dogs and of these, five returned to pre-injury levels of activity, including work. Complications requiring additional surgery were seen in four of the 13 cases, and three of these cases had a sub-optimal functional outcome. CLINICAL SIGNIFICANCE: The results following repair of Y-T fractures using SOP locking plates, placed via combined medial and lateral incisions, compared favourably with those reported for other techniques.


Assuntos
Placas Ósseas/veterinária , Doenças do Cão/cirurgia , Cães/lesões , Membro Anterior/cirurgia , Fraturas Ósseas/veterinária , Animais , Fraturas Ósseas/cirurgia , Úmero , Complicações Pós-Operatórias
9.
J Small Anim Pract ; 50(5): 224-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19425171

RESUMO

OBJECTIVE: To estimate specificity, sensitivity, positive predictive value and negative predictive value of tests and signs used for the diagnosis of cranial cruciate ligament failure in dogs. METHODS: One stifle in each of 42 dogs was examined: 25 "affected" and 17 "control" dogs. All dogs were subjected to the following tests when conscious: cranial drawer, tibial compression, patellar tendon palpation and palpation of the medial aspect of the joint. Under general anaesthesia, cranial drawer and tibial compression tests were repeated and a lateral stifle radiograph was taken to evaluate changes of the infrapatellar fat pad. The results were analysed using a 2 x 2 table method. Sensitivity, specificity, positive predictive value and negative predictive value were estimated. RESULTS: The sensitivity of the cranial drawer and tibial compression tests was surprisingly low when performed on conscious patients but significantly better when performed under anaesthesia. Similarly, palpation of the medial aspect of the stifle joint cannot be considered a reliable indicator of cranial cruciate ligament injury. Patellar palpation and radiographic assessment showed excellent sensitivity, specificity, positive predictive value and negative predictive value. CLINICAL SIGNIFICANCE: In the diagnosis of cranial cruciate ligament, it is essential that the clinician is aware of each test's features and limitations to reduce the risk of misdiagnosis.


Assuntos
Ligamento Cruzado Anterior/diagnóstico por imagem , Doenças do Cão/diagnóstico , Coxeadura Animal/diagnóstico , Palpação/veterinária , Exame Físico/veterinária , Joelho de Quadrúpedes/diagnóstico por imagem , Animais , Estudos de Casos e Controles , Cães , Instabilidade Articular/diagnóstico , Palpação/métodos , Palpação/normas , Exame Físico/métodos , Exame Físico/normas , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Vet Comp Orthop Traumatol ; 22(2): 132-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19290394

RESUMO

Locking plates are becoming increasingly popular in veterinary orthopaedics. The SOP is a novel locking plate system, which can be contoured with 6 degrees of freedom and which utilises standard bone screws. The purpose of this work was to investigate the mechanical consequences of contouring the 3.5 SOP plate to support the formulation of clinical guidelines. The implants were loaded in four point bending using an industry standard protocol. The uncontoured SOP was found to be significantly stiffer and stronger than the uncontoured 3.5 DCP. Bending, and to a lesser extent, twisting, diminished the SOP's stiffness and strength but the contoured SOP remained at least as stiff and strong as the untouched DCP.


Assuntos
Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Fixadores Internos/veterinária , Teste de Materiais/veterinária , Animais , Fenômenos Biomecânicos , Força Compressiva , Análise de Falha de Equipamento , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/normas , Fixadores Internos/normas , Teste de Materiais/instrumentação , Estresse Mecânico , Resistência à Tração
11.
J Small Anim Pract ; 49(4): 170-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18339087

RESUMO

OBJECTIVES: To evaluate staff nasal colonisation with meticillin-resistant Staphylococcus aureus in a veterinary orthopaedic referral hospital, and its effect on the occurrence of meticillin-resistant Staphylococcus aureus-associated postoperative wound complications in orthopaedic and spinal surgical patients. METHODS: Nasal bacterial swabs were collected from veterinary staff and environmental surfaces swabbed at six monthly intervals for meticillin-resistant Staphylococcus aureus monitoring over an 18 month period. The incidence of meticillin-resistant Staphylococcus aureus-associated postoperative wound complications of two veterinary orthopaedic surgeons was reviewed for a period when one was positive for nasal meticillin-resistant Staphylococcus aureus. RESULTS: Meticillin-resistant Staphylococcus aureus was isolated from a maximum of two out of 10 staff on each occasion. The persistently infected clinician was primary surgeon in 180 cases, of which four developed meticillin-resistant Staphylococcus aureus-associated wound complications. None of 141 operations led by the other surgeon developed meticillin-resistant Staphylococcus aureus-associated complications. This difference is not statistically significant (P=0.0974). The 95 per cent confidence interval for this odds ratio was 0.83 to 44.0. Meticillin-resistant Staphylococcus aureus resistance patterns of the human nasal isolates and three of four wound-associated isolates were similar. CLINICAL SIGNIFICANCE: Veterinary workers are at increased risk for meticillin-resistant Staphylococcus aureus colonisation, so it is likely that many veterinary patients are treated by meticillin-resistant Staphylococcus aureus-positive staff. Nasal colonisation of veterinary surgeons with meticillin-resistant Staphylococcus aureus appears to present only a small risk to their patients when appropriate infection control procedures are followed.


Assuntos
Hospitais Veterinários , Resistência a Meticilina , Cavidade Nasal/microbiologia , Infecções Estafilocócicas/transmissão , Infecções Estafilocócicas/veterinária , Zoonoses , Animais , Antibacterianos/uso terapêutico , Portador Sadio , Doenças do Gato/epidemiologia , Doenças do Gato/etiologia , Doenças do Gato/transmissão , Gatos , Infecção Hospitalar , Doenças do Cão/epidemiologia , Doenças do Cão/etiologia , Doenças do Cão/transmissão , Cães , Feminino , Humanos , Transmissão de Doença Infecciosa do Profissional para o Paciente , Masculino , Prevalência , Fatores de Risco , Staphylococcus aureus/efeitos dos fármacos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/veterinária , Médicos Veterinários
12.
Vet Comp Orthop Traumatol ; 20(4): 277-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18038003

RESUMO

The purpose of this study was to compare the holding powers of 2.7 mm pre-tapped and self-tapped screws placed closely together and tightened in small bones. Pairs of metatarsals were collected from healthy, skeletally mature Greyhounds and part of a 2.7 mm dynamic compression plate was fixed to the dorsal surface of each bone using three 2.7 mm screws. Identical screws were used throughout but only one of each pair of bones had threads pre-cut using a tap prior to insertion. All of the screws were tightened before the constructs were mounted in a materials testing machine and the centrally placed screw was loaded incrementally until failure. Load-deformation curves were plotted and yield point, ultimate load to failure, stiffness and energy prior to yield point were measured. Mean values were recorded for each parameter and Student's T-test was used to test the null hypothesis that there is no difference in holding power between pre-tapped and self-tapped screws. Significant mechanical differences were not found between pre-tapped and self-tapped screws placed closely together and tightened into small bones. Self-tapped screws can be considered for use in small animal surgery even when multiple screws are to be placed closely together in relatively small pieces of bone.


Assuntos
Parafusos Ósseos/veterinária , Cães/lesões , Fixação Intramedular de Fraturas/veterinária , Fraturas Ósseas/veterinária , Ossos do Metatarso/lesões , Animais , Fenômenos Biomecânicos , Cães/cirurgia , Desenho de Equipamento , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Fraturas Ósseas/cirurgia , Teste de Materiais , Ossos do Metatarso/cirurgia
13.
J Small Anim Pract ; 47(2): 83-8, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16438695

RESUMO

OBJECTIVES: To assess the use of external skeletal fixation with open wound management for the treatment of inherently unstable open or infected fractures in dogs. METHODS: A retrospective review of 10 cases. RESULTS: Fracture stabilisation and wound management required only a single anaesthetic, and despite the challenging nature of these injuries, the final outcome was acceptable or good in every case. However, minor complications associated with the fixator pins were quite common, and two dogs developed complications which required additional surgery. CLINICAL SIGNIFICANCE: Open management of wounds, even when bone was exposed, proved to be an effective technique, and external skeletal fixators were usually effective at maintaining stability throughout an inevitably extended fracture healing period.


Assuntos
Fixadores Externos/veterinária , Consolidação da Fratura/fisiologia , Fraturas Expostas/veterinária , Infecção da Ferida Cirúrgica/veterinária , Animais , Cães , Feminino , Fraturas Expostas/cirurgia , Fraturas Expostas/terapia , Masculino , Complicações Pós-Operatórias/veterinária , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/cirurgia , Infecção da Ferida Cirúrgica/terapia , Resultado do Tratamento , Cicatrização/fisiologia
14.
Vet Rec ; 142(19): 515-6, 1998 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-9618876

RESUMO

Progressive ataxia and quadriparesis in two shih tzu littermates was found to be caused by almost identical, cranial cervical, spinal arachnoid cysts. The cysts were treated surgically by dural marsupialization via a dorsal laminectomy. One pup recovered uneventfully and remains clinically normal more than a year after surgery. The second pup made a slow and incomplete recovery before the signs worsened, necessitating euthanasia. Postmortem examination showed no evidence of the re-formation of the cyst.


Assuntos
Cistos Aracnóideos/veterinária , Doenças do Cão/congênito , Animais , Cistos Aracnóideos/diagnóstico , Cistos Aracnóideos/cirurgia , Doenças do Cão/diagnóstico , Doenças do Cão/cirurgia , Cães , Masculino , Mielografia/veterinária , Cirurgia Veterinária , Resultado do Tratamento
15.
J Small Anim Pract ; 39(1): 15-8, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9494929

RESUMO

Fragmented coronoid process in 13 elbows (10 dogs) was treated by medial elbow arthrotomy plus osteotomy of the proximal ulnar diaphysis. All the dogs were skeletally immature and had a lameness of at least four weeks' duration. An attempt was made to measure the disease-modifying effect of this procedure by estimating the development of osteophytosis. Complications were infrequent and never serious. Clinical outcome, overall, was good. This preliminary work indicates that proximal ulnar diaphyseal osteotomy may have a place in the management of fragmented coronoid process in young dogs.


Assuntos
Cães/lesões , Coxeadura Animal/cirurgia , Osteotomia/veterinária , Fraturas da Ulna/veterinária , Ulna/cirurgia , Animais , Cães/cirurgia , Feminino , Seguimentos , Coxeadura Animal/diagnóstico por imagem , Masculino , Osteotomia/métodos , Radiografia , Ulna/diagnóstico por imagem , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/cirurgia
16.
Vet Rec ; 141(8): 197-200, 1997 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-9292975

RESUMO

Malignant articular neoplasia in two dogs was diagnosed as plasma cell neoplasia on the basis of radiography and cytology, and was supported by histopathology. Both dogs were euthanased and widespread metastases were identified postmortem.


Assuntos
Neoplasias Ósseas/veterinária , Doenças do Cão , Mieloma Múltiplo/veterinária , Animais , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Diagnóstico Diferencial , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Cães , Feminino , Humanos , Masculino , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Radiografia
17.
J Small Anim Pract ; 36(6): 252-4, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7650921

RESUMO

Four cases of isolated fracture of the radial diaphysis were diagnosed. All cases were successfully managed conservatively. Direct trauma was not a feature in any of the cases. The history, presenting signs and fracture morphology in each case were similar suggesting a common aetiology. The case histories are reviewed and a possible aetiology discussed.


Assuntos
Diáfises/lesões , Doenças do Cão/terapia , Fraturas do Rádio/veterinária , Animais , Diáfises/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Cães , Feminino , Masculino , Radiografia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/terapia
18.
Vet Rec ; 132(24): 608-9, 1993 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-8337809

RESUMO

A lakeland terrier puppy had progressive hindlimb ataxia associated with pain in the thoracic spine. Plain radiographs revealed a lesion affecting the dorsal neural arch of the fourth thoracic vertebra and myelography revealed compression of the spinal cord associated with the lesion. Surgical excision of the mass cured the dog's clinical signs. A histopathological examination of the excised tissue supported a diagnosis of osteochondromatosis.


Assuntos
Doenças do Cão/etiologia , Osteocondroma/veterinária , Paraplegia/veterinária , Neoplasias da Coluna Vertebral/veterinária , Vértebras Torácicas , Animais , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Doenças do Cão/cirurgia , Cães , Masculino , Mielografia/veterinária , Osteocondroma/complicações , Osteocondroma/patologia , Osteocondroma/cirurgia , Paraplegia/etiologia , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/veterinária , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...