Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 66(5): 1371-1378, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28602623

RESUMO

OBJECTIVE: The objective of this study was to evaluate the results of the off-label use of the Nellix endograft (Endologix, Irvine, Calif) for the treatment of short-neck aneurysms and juxtarenal aortic aneurysms (JAAs) compared with the outcomes of patients with infrarenal abdominal aortic aneurysms treated in accordance with the manufacturer's instructions for use. METHODS: Data available from patients treated with the Nellix endograft from September 2013 to January 2016 were reviewed to create a case-control analysis (1:2). Fourteen elective patients with a short-neck aneurysm or JAA (<10 mm) and mild aortic neck angulation (<35 degrees) were included. As a control group, 28 elective patients who had been treated in accordance with instructions for use were included. Patients were matched for age, sex, aortic diameter, and aortic neck angulation. The final cohort group included 42 patients: 14 in the JAA off-label group (5 with aortic neck length ≤4 mm and 9 with necks of 5 to 10 mm) and 28 in the control group. Technical and clinical success, freedom from any secondary intervention, any type of endoleak, and aneurysm-related death were evaluated. RESULTS: There were no significant differences between the two groups in terms of comorbidity, intraoperative time, radiation time, contrast agent volume, and perioperative mortality and morbidity. Two patients of the JAA group subsequently underwent open repair (14%), both with aortic neck length <4 mm (2/5; 40%), for type Ia endoleak. Two of the control group also subsequently underwent open repair (7%). At a mean follow-up of 22 ± 3.9 months, freedom from any reintervention was 85% for the JAA off-label group vs 92% for the control group (log-rank test, P = .33). CONCLUSIONS: The off-label use of the Nellix endograft for the treatment of JAA showed a higher rate of subsequent conversion to open repair for JAA patients (aortic neck length ≤4 mm), underlining the need for a proximal sealing zone. Longer term data are needed to verify the possible use of the Nellix endograft in selected short-neck aneurysms with aortic neck length >5 mm.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Itália , Masculino , Duração da Cirurgia , Rotulagem de Produtos , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Vasc Surg ; 62(5): 1219-26, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26391459

RESUMO

OBJECTIVE: We compared the outcomes and the durability of endovascular recanalization (EVR) with the Viabahn (W. L. Gore and Associates, Flagstaff, Ariz) covered stent graft vs traditional aortobifemoral or aortofemoral bypass grafting for complex aortoiliac occlusions. METHODS: Between 2008 and 2014, 11 unilateral iliac occlusions and 11 aortobiiliac occlusions were treated by EVR. Also collected were data from the last 21 consecutive patients treated in the same period by aortofemoral (n = 6) or aortobifemoral (n = 15) bypass grafting. In accordance with the TransAtlantic Inter-Society Consensus II (TASC II) document, only patients with type D lesions were considered. Kaplan-Meier estimates for patency were calculated, and Cox proportional hazard modeling was performed. RESULTS: The difference in risk factors between the groups was not significant. General anesthesia was required in 100% of the surgical group, and local or locoregional anesthesia was used for EVR. Suprarenal aortic cross-clamping was required in nine of the open surgical procedures (41%). A brachial percutaneous approach was performed in all patients undergoing EVR, and technical success was 100% in both groups. All of the attempts at EVR were successful. At the 2-year follow-up, primary patency did not differ significantly between the endovascular (91%) and surgical (95%) groups. This was seen in the univariate model (hazard ratio [HR], 0.27; 95% confidence interval [CI], 0.02-2.95; P = .28) and in the multivariate model (HR, 0.77; 95% CI, 0.06-10.07; P = .84) for group (HR, 0.58; 95% CI, 0.04-7.72; P = .68), age (HR, 0.89; 95% CI, 0.73-1.08; P = .24), symptoms (HR, 1.98; 95% CI, 0.42-9.46; P = .39), and occlusion (HR, 3.22; 95% CI, 0.51-20.35; P = .21). The average hospital length of stay was shorter for patients treated with ERV than for those treated with open surgery (3.9 ± 2.2 vs 5.8 ± 3.1 days, respectively; P = .03). The complication rate was 4% for EVR vs 18% in the surgical group (P = .32). CONCLUSIONS: At 2 years of follow-up, the results of endoluminal bypass grafting with the Viabahn stent to treat complex aortoiliac disease are promising. Longer-term results are needed to fully evaluate the potential benefits and longer-term patency.


Assuntos
Aorta Abdominal/cirurgia , Doenças da Aorta/cirurgia , Arteriopatias Oclusivas/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca/cirurgia , Stents , Idoso , Aorta Abdominal/fisiopatologia , Doenças da Aorta/diagnóstico , Doenças da Aorta/fisiopatologia , Aortografia , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Distribuição de Qui-Quadrado , Constrição Patológica , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Artéria Ilíaca/fisiopatologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
Ann Vasc Surg ; 29(8): 1659.e1-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26256709

RESUMO

We report a case of a metachronous common iliac artery and the internal iliac artery (IIA) aneurysm developed 8 years after an aortobi-femoral bypass for treatment of abdominal aortic aneurysm associated at chronic occlusion of the right iliac axis. To exclude the metachronous aneurysm on the left iliac axis and to maintain the pelvic circulation, an external to IIA endografts were positioned ("U stent-graft technique"). At 6-month follow-up, the computed tomography scan showed patency of the endografts, of the bypass and of the IIA, without endoleak, or other adverse events.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/diagnóstico , Aneurisma Ilíaco/cirurgia , Stents , Idoso , Humanos , Aneurisma Ilíaco/etiologia , Masculino
4.
Ann Vasc Surg ; 29(7): 1451.e5-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26122421
5.
Ann Vasc Surg ; 28(8): 1931.e9-1931.e12, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25017771

RESUMO

We report a case of abdominal endograft proximal collapse due to acute type B aortic dissection in a patient previously treated with endovascular repair (EVAR) for an infrarenal abdominal aortic aneurysm. Patient underwent axillobifemoral bypass grafting, in emergency. The postoperative computed tomography scan showed reexpansion of the occluded endograft. The patient died after 2 days with evidence of progression of the thrombosis of the false lumen and with involvement of renal, visceral, and medullar artery. EVAR collapse associated to acute type B aortic dissection is a challenging condition, which requires aggressive approach.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico , Aneurisma da Aorta Abdominal/diagnóstico , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Evolução Fatal , Humanos , Masculino , Desenho de Prótese , Reoperação , Estresse Mecânico , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Ann Vasc Surg ; 28(7): 1795.e11-4, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24858585

RESUMO

A 59-year-old male, referred to our center with a ruptured aortic aneurysm, underwent urgent endovascular repair and femoro-femoral crossover bypass. An endograft infection because of Aspergillus fumigatus occurred about 20 days after surgery. We removed the endograft and femoral prosthesis and we then performed an aorto-bi-iliac bypass with autogenous reversed superficial femoral veins. Five days after surgery, the patient died. Microbiological examination and postmortem examination showed the presence of A. fumigatus in femoral prosthesis, aortic wall, and periaortic exudate.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Aspergilose/diagnóstico , Aspergillus fumigatus/isolamento & purificação , Prótese Vascular/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Implante de Prótese Vascular/métodos , Remoção de Dispositivo , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade
7.
Ann Vasc Surg ; 28(1): 227-38, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24011816

RESUMO

BACKGROUND: Large randomized controlled trials have shown that carotid endarterectomy (CEA) is beneficial in the treatment of recent severe symptomatic carotid stenosis. Data are lacking concerning the risks of early CEA (<48 hours) for stroke in evolution (SIE) or crescendo transient ischemic attack (CTIA). The primary end point of this retrospective study was to evaluate the incidence of stroke, major adverse cardiac events (MACEs), and death within the first 30 days after early CEA performed within 48 hours in patients presenting with transient ischemic attack (TIA)/SIE. METHODS: Between 2001 and 2010, we treated 3,023 carotid artery stenoses, 29.5% (891/3,021) of which were in symptomatic patients. Early CEA within 48 hours after acute TIA/SIE was performed in 176 patients. Patients were divided into 3 groups for analysis of outcome after early CEA in symptomatic patients according to their initial neurologic deficit. Group 1 included 55 patients with TIA (single); group 2 included 55 patients with CTIA, and group 3 included 66 patients with SIE. Carotid artery stenosis was evaluated by duplex ultrasonography (DS). All patients were pre- and postoperatively visited by an experienced consultant neurologist who evaluated the neurologic status according to the modified Rankin Scale and the National Institutes of Health Stroke Scale (NIHSS). At admission, surgery was not performed on patients with disabling neurologic deficit (NIHSS score: >6) except for 4 selected cases (NIHSS score range: 8-14), patients with cerebral lesions >3 cm in diameter, patients with the presence or suspicion of parenchymal hemorrhage, patients with occlusion of the middle cerebral artery, and those who were deemed unfit for surgery. Clinical and DS follow-up examinations were performed after 6 and 12 months and annually thereafter. The mean duration of follow-up was 29.4 months (range: 0-120 months). RESULTS: The cumulative TIA/stroke/myocardial infarction/death rate at 30 days was 3.9% (7/176). TIA and stroke rates were 0% (0/176) and 3.4% (6/176), respectively. The stroke rate in groups 1, 2, and 3 was 1.8% (1/55), 0% (0/55), and 7.6% (5/66), respectively. No hemorrhagic strokes, TIAs, or MACEs were detected after surgery. Stroke risk was higher in group 3 than in groups 1 or 2, but the differences in the 3 groups were not statistically significant (group 1 vs. group 2: 1/55 vs. 0/55 events [P = 0.3151]); group 1 vs. group 3: 1/55 vs. 5/66 events [P = 0.3020]; and group 2 vs. group 3: 0/55 vs. 5/66 events [P = 0.1039]. Thirty-day follow-up was available for all patients, while long-term follow-up (mean: 32.7 ± 26.8 months) was available only for 158 patients (1 patient died and 17 were lost to follow-up). CONCLUSIONS: CEA can be performed with an acceptable risk in properly selected symptomatic patients within 48 hours after TIA or SIE. The benefits of early CEA in symptomatic patients include the prevention of recurrent stroke.


Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Ataque Isquêmico Transitório/etiologia , Acidente Vascular Cerebral/etiologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/mortalidade , Avaliação da Deficiência , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/mortalidade , Ataque Isquêmico Transitório/prevenção & controle , Exame Neurológico , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Prevenção Secundária , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
8.
J Vasc Surg ; 60(5): 1348-1352, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24199766

RESUMO

Despite the improvement in diagnostic and therapeutic strategies, the treatment of thoracoabdominal aneurysms is still burdened with a high incidence of peri/postoperative morbidity and mortality. The multilayer flow modulator is a new and promising technique for the treatment of such disease; however, some limits are still evident. We report the case of a 76-year-old woman affected by a symptomatic thoracoabdominal aneurysm treated with multiple Cardiatis multilayer flow modulators complicated by aortic arch rupture on the fifth postoperative day, with subsequent patient death.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/fisiopatologia , Aortografia/métodos , Autopsia , Evolução Fatal , Feminino , Hemodinâmica , Humanos , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
J Endovasc Ther ; 20(3): 393-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23731314

RESUMO

PURPOSE: To report midterm failure of tandem peripheral multilayer stents used to treat a common hepatic artery aneurysm (HAA) that had a good early result. CASE REPORT: A 71-year-old man with multiple comorbidities had a 3.4-cm HAA treated with 2 Cardiatis peripheral multilayer stents (8×100 and 9×60 mm) that overlapped by 3 cm. At the 12-month follow-up, the stents were patent, with signs of collateral patency and full thrombosis of the aneurysm sac without expansion. At the 18-month visit, the sac had expanded to 4.5 cm without signs of revascularization, but there was an initial stent dislocation; a wait and watch approach was elected. On the 24-month imaging, the HAA had enlarged to 6 cm, with disconnection of the 2 stents. A new multilayer stent (9×100 mm) was positioned to "bridge" the gap; however, the proximal part of the new stent did not correctly expand despite multiple attempts to overcome the infolding. The 3 stents became completely thrombosed, but thanks to rich mesenteric collaterals, perfusion of the proper hepatic artery was adequate. CONCLUSION: The multilayer peripheral stent appears to be an alternative for the treatment of visceral aneurysms in patients with a high surgical risk, but it is not a conventional stent. There are unknowns about its function, behavior, and application. Therefore, more experience is needed to validate the effectiveness of the multilayer stent.


Assuntos
Aneurisma/cirurgia , Artéria Hepática/cirurgia , Falha de Prótese , Stents , Idoso , Humanos , Masculino , Desenho de Prótese , Fatores de Tempo
10.
Ann Vasc Surg ; 27(7): 856-64, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23790763

RESUMO

BACKGROUND: The endovascular treatment of an abdominal aortic aneurysm (AAA) is a treatment with low risk and good reported results. This retrospective study analyzed experience with patients requiring surgical conversion after endovascular abdominal aortic aneurysm repair (EVAR). METHODS: A total of 26 patients underwent open conversion (OC) after EVAR (18 endografts implanted at the authors' center and 8 in other centers). Patients were divided into 2 groups: early conversion if OC was performed within 30 days from the primary EVAR, and late conversion if OC was performed at least 30 days after EVAR. The authors analyzed all data on OC and the postoperative course. RESULTS: In this series, OC was performed for 22 endoleaks (13 type I, 5 type II, 2 type III, and 2 type V, which in 5 cases these were associated with AAA ruptures), 2 renal artery coverages, and 2 endograft infections. Six (23%) patients underwent early conversion with a mortality rate of 50%, and 20 (77%) had late conversion with a mortality rate of 20%. The overall mortality rate after OC, occurring before hospital discharge or within 30 days, was 26.9% (7 of 26). CONCLUSIONS: Endoleaks remain the weak point of endografts and can result in aneurysm rupture/death. Urgent OC and infections engender a high mortality. Elective OC can be performed with very low mortality and acceptable morbidity. Lifelong surveillance is necessary to detect and treat endoleaks.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/etiologia , Ruptura Aórtica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Procedimentos Cirúrgicos Eletivos , Emergências , Endoleak/diagnóstico , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Am J Cardiol ; 112(4): 612-3, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23672986

RESUMO

Percutaneous closure of an atrial septal defect has been increasingly used, and complications have been rare. We report the case of a 63-year-old man who had undergone endovascular closure of a secundum atrial septal defect months earlier. The occluder was later found in the abdominal aorta.


Assuntos
Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/terapia , Comunicação Interatrial/cirurgia , Perna (Membro)/irrigação sanguínea , Dispositivo para Oclusão Septal/efeitos adversos , Cateterismo Cardíaco , Remoção de Dispositivo , Ecocardiografia , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
13.
Ann Vasc Surg ; 26(2): 277.e1-3, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22079463

RESUMO

A 48-year-old woman was referred to us for a pulsatile and painful mass on the right leg after a trauma occurred 2 months earlier. The duplex scan revealed the presence of an aneurysm of the perforating peroneal artery. The patient underwent an endovascular coil embolization of the aneurysm. The duplex-scan follow-up showed the patency of the peroneal vessel and the complete aneurysm thrombosis. The patient was discharged in good condition without pain. In literature, only four cases of aneurysm of perforating peroneal artery aneurysm, all with a clear traumatic etiology, are reported. In this case, the endovascular treatment was safe and effective.


Assuntos
Aneurisma/etiologia , Extremidade Inferior/irrigação sanguínea , Lesões do Sistema Vascular/etiologia , Ferimentos não Penetrantes/etiologia , Aneurisma/diagnóstico , Aneurisma/terapia , Artérias/lesões , Embolização Terapêutica , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/terapia , Ferimentos não Penetrantes/diagnóstico , Ferimentos não Penetrantes/terapia
14.
Eur J Cardiothorac Surg ; 41(1): 177-82, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21820909

RESUMO

OBJECTIVE: Thoracic, arch, and proximal descending thoracic aorta diseases are still considered an enormous challenge. The hybrid approach developed in recent years (supra-aortic trunks debranching and thoracic endovascular repair aortic repair; TEVAR) may improve the morbidity and mortality of the population at risk. The aim of this study was to analyze retrospectively our experience in the hybrid treatment of aortic-arch aneurysms and dissections. METHOD: We carried out a retrospective review of 27 patients who required a surgical debranching of the supra-aortic trunks and a TEVAR in the management of the aortic arch and proximal descending thoracic aortic disease. The aortic lesions included 18 degenerative arch-aortic aneurysms, four complicated aortic dissections, two subclavian artery aneurysms, and three penetrating atherosclerotic ulcers. Technical success was achieved in all patients. RESULTS: The 30-day mortality rate was 11.1% (3/27). Mean follow-up was 16.7 months (range, 1-56), and the survival rate was 77.8%. The endoleaks' rate was 3.7% (1/27), due to a stent-graft migration. CONCLUSION: Hybrid approaches may represent an alternative option in the treatment of complex aortic lesions involving the arch and the proximal descending thoracic aorta in high-risk patients and emergency cases. However, the promising early results need to be confirmed by longer follow-up and larger comparative series.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/patologia , Aneurisma da Aorta Torácica/patologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Fatores de Risco , Stents , Resultado do Tratamento
15.
Ann Vasc Surg ; 25(8): 1142.e1-5, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22023952

RESUMO

Aortoesophageal fistula is rare but fatal if untreated. Open thoracic surgery is associated with high operative mortality and morbidity. We report a case of a 77-year-old man who, treated with thoracic endovascular aortic repair (TEVAR) for descending thoracic aneurysm in another center, after an acute episode of hematemesis and melena was referred to our center. The total body computed tomography scan showed the presence of reperfusion of the descending thoracic aneurysm sac (8.8 cm in diameter) in the proximal and distal TEVAR landing zone (endoleak type I) without clear signs of fistulous tract with the esophageal lumen. The patient underwent new TEVAR inside previous implantation with proximal landing very close to left subclavian artery and distal landing just above celiac trunk. For the presence of a tracheoesophageal fistula, an esophageal endoprosthesis was implanted few days later, and a jejunostomy was performed. At 30 days, patient was in good general condition, but he died at 3 months' follow-up. Aortoesophageal fistula is a rare and usually fatal condition; early recognition and TEVAR treatment prevent immediate exsanguination in patients, but after deployment of the endograft, most patients are at risk for infectious complications. Cessation of bleeding and restoration of circulation is of paramount urgency, but infectious diseases and esophageal repair remain open problems.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Erros de Diagnóstico , Procedimentos Endovasculares , Fístula Esofágica/cirurgia , Neoplasias Esofágicas/diagnóstico , Fístula Traqueoesofágica/cirurgia , Fístula Vascular/cirurgia , Idoso , Doenças da Aorta/diagnóstico , Doenças da Aorta/etiologia , Aortografia/métodos , Procedimentos Endovasculares/instrumentação , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiologia , Evolução Fatal , Humanos , Jejunostomia , Masculino , Desenho de Prótese , Reoperação , Tomografia Computadorizada por Raios X , Fístula Traqueoesofágica/diagnóstico , Fístula Traqueoesofágica/etiologia , Resultado do Tratamento , Fístula Vascular/diagnóstico , Fístula Vascular/etiologia
16.
Ann Vasc Surg ; 25(7): 923-35, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21831589

RESUMO

Between 2000 and 2010, 32 patients (17 males; mean age: 64.7 [range: 18-85] years) with visceral artery aneurysms (VAAs) were treated in our center. The site of aneurysmal disease was: splenic artery (18), hepatic artery (5), superior mesenteric artery (3), pancreaticoduodenal artery (3), celiac axis (2), and gastroduodenal (1). Six patients (18.75%) presented with an aneurysm rupture. Nine cases received an endovascular treatment. Primary technical success was achieved in six patients. Failures included one case of immediate stent occlusion, one stent migration, and one failed attempt of embolization. In 24 cases, the surgical treatment was performed successfully. The total survival rate was 90.6% (in urgency: 75%; in election: 95.8%). A follow-up period of 34.7 months (range: 2-117 months) showed good results. Because of the potential risk of rupture, VAAs should be treated. A new endovascular technology based on a multilayer stent could provide us with a new alternative to VAA treatment, guaranteeing both aneurysmatic sac thrombosis and the correct perfusion of the organs. However, this new technology is not suitable for all aneurysms and requires a specific training and learning curve. In subjects with a low surgical risk, surgery guarantees a definitive and long-lasting repair with a good organ perfusion.


Assuntos
Aneurisma/cirurgia , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Stents , Vísceras/irrigação sanguínea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/mortalidade , Aneurisma Roto/cirurgia , Artérias/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
17.
Interact Cardiovasc Thorac Surg ; 13(5): 545-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21831875

RESUMO

We wished to analyze our initial experience with the Cardiatis Multilayer Stent for visceral artery aneurysms. Two males with a hepatic artery aneurysm (34 mm and 48 mm in diameter, respectively) were treated, via a percutaneous femoral approach, with multilayer stents. We deployed the stent in front of the aneurysm neck, covering the hepatic artery branches. At 12 months, a computed tomography scan showed thrombosis of the aneurysmal sac and patency of all the branches of the hepatic artery. The Multilayer Stent appears to be a viable alternative for the treatment of visceral artery aneurysms in patients at high surgical risk, but long-term follow-up is needed.


Assuntos
Aneurisma/terapia , Procedimentos Endovasculares/instrumentação , Artéria Hepática , Stents , Idoso , Aneurisma/diagnóstico por imagem , Artéria Hepática/diagnóstico por imagem , Humanos , Masculino , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Ann Vasc Surg ; 25(7): 982.e11-4, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21680145

RESUMO

A 69-year-old man was referred to our facility owing to the sudden onset of a compression-like pain in the right leg, without limb-threatening acute ischemia. The duplex scan examination, followed by a selective leg angiography, showed the presence of a peroneal artery aneurysm. A diagnosis of mycotic aneurysm was made on the basis of the patient's clinical condition, positive blood cultures, and the unusual location of the lesion. Endovascular repair was performed by using a coil embolization and covered stent release. The patient was discharged in good general condition with complete pain relief. In previously published data, only four cases of peroneal artery aneurysm with a mycotic etiology have been reported. In this case, the endovascular treatment was safe and resolutive.


Assuntos
Aneurisma Infectado/terapia , Embolização Terapêutica , Endocardite Bacteriana/microbiologia , Procedimentos Endovasculares , Extremidade Inferior/irrigação sanguínea , Streptococcus mitis/isolamento & purificação , Idoso , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/microbiologia , Antibacterianos/uso terapêutico , Artérias/microbiologia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/cirurgia , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Stents , Ultrassonografia Doppler Dupla
19.
Ann Vasc Surg ; 25(7): 981.e7-11, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21665424

RESUMO

Five patients were treated for ruptured visceral artery aneurysms during the last 9 years, including two splenic and three pancreaticoduodenal aneurysms. The average size of aneurysm was 2.6 cm (range: 1.5-5 cm). All patients underwent open surgical treatment. There was one operative death. After a mean follow-up of 46.6 months, there were no cases of mortality or secondary complications. The authors conclude that operative treatment of ruptured visceral artery aneurysms is durable.


Assuntos
Aneurisma Roto/cirurgia , Procedimentos Cirúrgicos Vasculares , Vísceras/irrigação sanguínea , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/mortalidade , Artérias/cirurgia , Embolização Terapêutica , Feminino , Humanos , Ligadura , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...