Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 982
Filtrar
1.
J Endod ; 50(10): 1495-1504, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39094780

RESUMO

INTRODUCTION: To assess the effect of combinations of two different endodontic sealers used in initial and endodontic retreatment on the bond strength of the secondary obturation and the penetrability of the sealers. METHODS: Forty-eight mandibular premolars were used, receiving standardized endodontic access and biomechanical preparation. Twenty-four teeth received AH Plus sealer (AHP) in primary obturation and the others received Bio-C Sealer (BCS). Retreatment protocol was performed with an R50 instrument. The samples were further subdivided into four groups (n = 12) based on the combination of primary/secondary obturation sealers: AHP/AHP; AHP/BCS; BCS/AHP; and BCS/BCS. Four samples from each subgroup received the addition of fluorophores to the sealer for penetrability analysis using laser scanning confocal fluorescence microscopy. The root portion on the 8 push-out samples was sectioned into 6 slices of 1.0 mm. Bond strength (BS) was assessed using a universal testing machine until displacement of the filling mass. Failure pattern was evaluated under a stereomicroscope (20× magnification). BS data were analyzed using two-way analysis of variance followed by Tukey's test (P < .05), and the association between the failure pattern and BS value was assessed using the chi-square test (P < .05). Penetrability was qualitatively evaluated. RESULTS: The highest BS values were observed in the AHP/AHP (4.54 ± 1.5 MPa) and BCS/AHP (5.00 ± 1.0 MPa) groups (P < .05), with a higher percentage of adhesive failures to the filling material for all groups. Laser scanning confocal fluorescence microscopy images indicated greater penetrability of AHP compared to BCS, both in initial treatment and retreatment. CONCLUSION: AHP sealer exhibited higher BS and greater penetrability compared to BCS sealer.


Assuntos
Colagem Dentária , Retratamento , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/uso terapêutico , Colagem Dentária/métodos , Obturação do Canal Radicular/métodos , Tratamento do Canal Radicular/métodos , Dente Pré-Molar , Resinas Epóxi/uso terapêutico , Análise do Estresse Dentário
3.
Pharmaceuticals (Basel) ; 17(7)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39065700

RESUMO

The development and course of inflammatory bowel disease (IBD) are significantly influenced by inflammation and oxidative stress. Antioxidant therapy is a promising therapeutic option to enhance the clinical results of these individuals in this particular scenario. The purpose of this study is to assess the impact of curcumin, with or without piperine, on cytokines, fecal calprotectin (CalF), and oxidative stress enzymatic and non-enzymatic indicators in patients with IBD. METHODS: Patients with Crohn's disease (CD) or ulcerative colitis (UC) who were at least 18 years old and had intact liver and kidney function participated in this randomized, double-blind trial (trial registration: ensaiosclinicos.gov.br as RBR-89q4ydz). For 12 weeks, participants were randomly assigned to one of three groups: placebo, curcumin (1000 mg/day), or curcumin plus piperine (1000 mg + 10 mg/day). In order to examine oxidative stress indicators, CalF, and pro-inflammatory cytokines, blood and fecal samples were obtained, both prior to and following the intervention time. RESULTS: After adjusting for age, sex, and type of IBD, the curcumin plus piperine group had substantially higher serum levels of superoxide dismutase (SOD) than the placebo group (4346.9 ± 879.0 vs. 3614.5 ± 731.5; p = 0.041). There were no discernible variations between the groups in CalF, inflammatory markers, or other indicators of oxidative stress. CONCLUSIONS: In patients with inflammatory bowel disease (IBD), our study indicates that a 12-week curcumin plus piperine treatment effectively increases enzymatic antioxidant defense, especially SOD. These results demonstrate the potential therapeutic benefits of managing redox imbalance in individuals with IBD.

4.
Arq Neuropsiquiatr ; 82(9): 1-7, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39025107

RESUMO

BACKGROUND: Olfactory dysfunction (OD) represents a frequent manifestation of the coronavirus disease 2019 (COVID-19). Apolipoprotein E (APOE) is a protein that interacts with the angiotensin-converting enzyme receptor, essential for viral entry into the cell. Previous publications have suggested a possible role of APOE in COVID-19 severity. As far as we know, no publications found significant associations between this disease's severity, OD, and APOE polymorphisms (E2, E3, and E4). OBJECTIVE: To analyze the epidemiology of OD and its relationship with APOE polymorphisms in a cohort of Long-COVID patients. METHODS: We conducted a prospective cohort study with patients followed in a post-COVID neurological outpatient clinic, with OD being defined as a subjective reduction of olfactory function after infection, and persistent OD being defined when the complaint lasted more than 3 months after the COVID-19 infection resolution. This cross-sectional study is part of a large research with previously reported data focusing on the cognitive performance of our sample. RESULTS: The final sample comprised 221 patients, among whom 186 collected blood samples for APOE genotyping. The persistent OD group was younger and had a lower hospitalization rate during the acute phase of the disease (p < 0.001). Furthermore, the APOE variant E4 allele frequency was lower in this group (p = 0.035). This study evaluated OD in an outpatient population with COVID-19. In the current literature on this disease, anosmia is associated with better clinical outcomes and the E4 allele is associated with worse outcomes. CONCLUSION: Our study provides new information to these correlations, suggesting APOE E4 as a protective factor for OD.


ANTECEDENTES: A disfunção olfatória (DO) é uma manifestação frequente da doença do coronavírus 2019 (COVID-19). A apolipoproteína E (APOE) é uma proteína que interage com o receptor da enzima conversora de angiotensina, essencial para a entrada viral na célula. Publicações anteriores sugeriram um possível papel da APOE na gravidade da COVID-19. Até onde sabemos, nenhuma publicação encontrou associações significativas entre a gravidade dessa doença, DO e polimorfismos da APOE (E2, E3 e E4). OBJETIVO: Analisar a epidemiologia da DO e sua relação com os polimorfismos do gene APOE em uma coorte de pacientes com COVID longa. MéTODOS: Um estudo de coorte prospectiva com pacientes acompanhados em ambulatório neurológico pós-COVID, com DO sendo definida como uma redução subjetiva da função olfativa após a infecção e a DO persistente sendo definida quando a queixa durou mais de 3 meses após a resolução da infecção por COVID-19. Este estudo transversal é parte de uma pesquisa maior com dados anteriormente relatados, focando na performance cognitiva dos pacientes. RESULTADOS: Foram selecionados 221 pacientes para esse estudo, dos quais 186 haviam coletado amostras de sangue para genotipagem APOE. O grupo DO persistente foi mais jovem e apresentou menor taxa de internação na fase aguda da doença (p < 0,001). Além disso, a frequência do alelo E4 da APOE foi menor nesse grupo (p = 0,035). Este estudo avaliou a DO em uma população com COVID longa. Na literatura atual sobre essa doença, a anosmia está associada a melhores desfechos clínicos e o alelo E4 está associado a piores desfechos. CONCLUSãO: Nosso estudo acrescenta novas informações a essas correlações, sugerindo a APOE E4 como um fator de proteção para DO.


Assuntos
Alelos , COVID-19 , Transtornos do Olfato , Humanos , COVID-19/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Transtornos do Olfato/genética , Estudos Transversais , Apolipoproteína E4/genética , Idoso , Adulto , Fatores de Proteção , Apolipoproteínas E/genética , Polimorfismo Genético , SARS-CoV-2 , Genótipo , Síndrome de COVID-19 Pós-Aguda
5.
J Endod ; 50(10): 1484-1494, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39038534

RESUMO

INTRODUCTION: The aim of this study was to evaluate the volume of dentin removal and the volume of remnants of restorative material after the removal of an esthetic restorative coronal set and cervical barrier in endodontically treated mandibular molars with the aid of different magnification methods using 3-dimensional (3D) micro-computed tomographic (micro-CT) morphometric analysis. METHODS: A sample of 30 mandibular first molars (N = 30) was used. All teeth were endodontically treated, and the specimens were initially scanned using micro-CT imaging and reconstructed. The molars were filled by a single-cone technique, and immediately the material at the initial 2-mm cervical level was removed. Cervical barriers were confected using ionomer glass cement with fluorescein 0.1%, filling the 2 mm at the cervical level of the canals and an additional 2 mm as the base. The coronal restoration set was performed using esthetic resin composites. A simulated tooth aging process was performed with 20,000 thermocycling cycles. The sample was distributed into the following 3 groups (n = 10) for the removal of the restoration set and cervical barrier with diamond burs based on the magnification aid: no magnification aid (naked eye), operative microscope aid, and REVEAL device (Design for Vision Inc, Bohemia, NY) aid. After removal, the final 3D micro-CT scanning and reconstruction were conducted with the same parameters as the initial scanning, and superposition of the final and initial scanning was performed. Morphometric analysis was conducted using CTAn software (Bruker microCT, Kontich, Belgium) to assess the volume of remnant restorative material (mm³), the volume of dentin removal (mm³), and the direction and site of dentin removal. Data were analyzed using 1-Way analysis of variance (P < .05). RESULTS: The REVEAL group showed better results regarding the volume of remnant material (3.17 ± 1.65) and the percentage of dentin removal (2.56 ± 1.34). The microscope group showed no statistical difference compared with the REVEAL group regarding dentin removal (3.30 ± 1.48) and was statistically similar to the naked eye group in the volume of remnant material (9.63 ± 4.33). The naked eye group showed the worst results for the volume of remnant material (7.60 ± 2.68) and the percentage of dentin removal (6.60 ± 3.70). CONCLUSIONS: The use of fluorescence associated with magnification was the method that presented the best results, with lower percentages of dentin removal and smaller volumes of remaining restorative material. This is an innovative technology in endodontics that shows potential to overcome the challenge of reaccessing root canals in the context of endodontic retreatment.


Assuntos
Cavidade Pulpar , Microtomografia por Raio-X , Microtomografia por Raio-X/métodos , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Fluorescência , Dente não Vital/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Imageamento Tridimensional/métodos , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação
6.
Front Vet Sci ; 11: 1385481, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38840627

RESUMO

The objective of this study was to evaluate the effect of the transport distance and lairage time on behavioral indicators of zebu beef cattle in the resting pen of a slaughterhouse using the focal animal technique. Eight lots of male zebu cattle, Nelore, aged approximately 4 years old, weighing on average 500 ± 28.5 kg-1, from different municipalities, transported by land, were evaluated. The lots were grouped into two categories: short distance (> 500 km) and long distance (> 500 km). Five focal animals per evaluated lot were used in each cycle of behavior observation, randomly chosen, and visually identified. The animal focal sampling method was used, with instantaneous recording, every 5 min per animal/h. A video camera was used and placed at a fixed point in the corral. After slaughtering, bruises and carcass pH were evaluated. The respiratory rate (RR) was measured in two moments, 30 min after unloading (RR_I) and 1 h before slaughtering (RR_F); behavioral data were divided into four lairage periods (1st, 2nd, 3rd, and 4th) equally and evaluated as repeated measures over time. The lairage time lowered the behaviors of headbutting (NCHBs), pushing (PsH), mounting (MT), and chasing away (CA), (p = 0.0001), and these behaviors were more evident in animals transported for short distances in the initial resting times, decreasing as they remained in the resting pen. There was effect of distance on the initial and final pH of the carcass, being greater in the short distance (p = 0.047). There was no effect of distance or lairage time on initial or final RR (p > 0.05). In addition, animals transported over long distances showed less carcass injuries, which were observed during post mortem inspection. It is concluded that animals transported over short distances present a greater number of agonistic behaviors, such as NCHBs, MT, PsH, and CA, predisposing to higher rates of bruising during lairage and more accentuated changes in the final pH of the meat.

7.
Heart Lung ; 67: 183-190, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38848628

RESUMO

BACKGROUND: Obstructive sleep apnoea (OSA) is a disabling health condition, and there is no disease-specific patient-reported outcome instrument to assess individuals with OSA. OBJECTIVES: To evaluate the psychometric properties of the Brazilian version of the World Health Organization Disability Assessment Schedule (WHODAS 2.0) in individuals with OSA. METHODS: One hundred individuals with OSA responded to the WHODAS 2.0 version of 36 items, the Epworth Sleepiness Scale (ESS), the Pittsburgh Sleep Quality Index (PSQI), and the 12-item health survey (SF-12). Internal consistency, convergent and discriminative validity, and responsiveness to continuous positive airway pressure (CPAP) were the psychometric properties tested. RESULTS: Cronbach's α values indicate good internal consistency (0.91 - 0.73), except for the self-care domain (α = 0.52). Convergent validity indicated an excellent correlation (r = -0.80) between the domains of functioning and quality of life. Discriminative validity showed no association between OSA severity and functioning (p = 0.90). The responsiveness to CPAP treatment showed a large effect size (r = 0.82; p < 0.05) CONCLUSIONS: The WHODAS 2.0 instrument is valid, reliable, and responsive for assessing individuals with OSA.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Avaliação da Deficiência , Psicometria , Qualidade de Vida , Apneia Obstrutiva do Sono , Organização Mundial da Saúde , Humanos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Masculino , Feminino , Brasil , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Psicometria/instrumentação , Psicometria/métodos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Qualidade de Vida/psicologia , Inquéritos e Questionários , Adulto , Índice de Gravidade de Doença , Idoso , Polissonografia/métodos
8.
Food Chem ; 455: 139879, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38824725

RESUMO

We used confocal microscopy and spectrofluorescence to characterize the emission spectra in hop flowers, to follow the isomerization processes in different hop preparations, and beers, to compare with HPLC extracted samples. Flowers of different hop cultivars produced in three regions of Brazil, were quantitated by HPLC and GC-MS. The fluorescence spectra showed two characteristic emission bands evaluated from different preparations. The isomerization process leads to a gradual decrease in fluorescence intensity as the reaction progresses. This demonstrates the valuable use of confocal microscopy and fluorescence spectroscopy for analysis of the correlation between bitter acid indices with fluorescence intensity and lifetime microscopy. Such techniques can be used directly in the flowers allowing rapid monitoring of the brewing process. Twenty-nine substances were characterized in the essential oils and some cultivars presented quantities of bitter acids and essential oil levels close to those expected for plants after more than three years of cultivation.


Assuntos
Cerveja , Flores , Humulus , Microscopia Confocal , Óleos Voláteis , Brasil , Flores/química , Flores/metabolismo , Humulus/química , Cromatografia Líquida de Alta Pressão , Cerveja/análise , Óleos Voláteis/química , Isomerismo , Espectrometria de Fluorescência/métodos , Cromatografia Gasosa-Espectrometria de Massas
9.
Rev Esc Enferm USP ; 58: e20230269, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38808705

RESUMO

OBJECTIVE: To analyze nurses' practice in child health nursing consultations and the presence of care management competencies proposed for Advanced Practice Nurses (APN). METHOD: Multicenter, exploratory sequential mixed methods research, carried out in 17 Basic Health Units in four Brazilian cities. Collection was carried out from May to July 2022 through filming of consultation and analysis of medical records. Consultations with compliance with the Nursing Process ≥50% were analyzed to identify the competencies proposed for APN. RESULTS: 24 child consultations carried out by 12 nurses were filmed. In the quantitative analysis, 11 nursing consultations, carried out by seven nurses, achieved ≥50% Nursing Process compliance. In the qualitative analysis of these consultations, some APN competencies in care management were identified, but incomplete. CONCLUSION: child health nursing consultations present weaknesses in carrying out the Nursing Process, and nurses demonstrated a partial and superficial application of the care management competencies proposed for APN.


Assuntos
Prática Avançada de Enfermagem , Competência Clínica , Enfermagem Pediátrica , Humanos , Prática Avançada de Enfermagem/normas , Brasil , Enfermagem Pediátrica/normas , Criança , Masculino , Feminino , Adulto , Pré-Escolar , Processo de Enfermagem/normas , Encaminhamento e Consulta , Lactente
10.
Dentomaxillofac Radiol ; 53(5): 308-315, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38608191

RESUMO

OBJECTIVE: To compare digital panoramic radiography (DPR) and cone beam CT (CBCT) in the detection and classification of pulp calcifications in posterior teeth in relation to tooth condition and its location. METHODS: Two hundred and fifty patients with simultaneous DPR and CBCT scans were selected from a dental image bank. For each posterior tooth, its condition was registered (healthy, restored, or decayed). The presence of calcifications was assessed and classified according to location (coronal or radicular) and type (total obliteration, partial obliteration, narrowing, and no calcification). Chi-square and McNemar tests were used to compare DPR and CBCT results, with a significance level of 5%. DPR diagnostic values were calculated using CBCT as reference. RESULTS: Decayed and restored teeth showed a significantly (P < .001) higher prevalence of pulp calcifications than healthy teeth in both imaging exams. There was a significant discrepancy between the imaging modalities in the identification of calcifications (P < .001), especially for radicular calcifications of maxillary teeth (DPR = 55.2%; CBCT = 30.9%). In the case of coronal calcifications, there was a greater discrepancy between CBCT and DPR in the mandibular teeth (10.7%) than in the maxillary teeth (7.7%). Overall, DPR presents higher sensitivity (0.855) than specificity (0.483) for pulp calcifications detection. CONCLUSION: DPR considerably overestimates pulp calcifications in posterior teeth, as compared to CBCT. A higher prevalence of pulp calcifications is related to decayed and restored teeth.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Calcificações da Polpa Dentária , Radiografia Dentária Digital , Radiografia Panorâmica , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Calcificações da Polpa Dentária/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Adolescente , Idoso , Dente Molar/diagnóstico por imagem
11.
Microsc Res Tech ; 87(8): 1810-1821, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38530150

RESUMO

Molar-incisor hypomineralization (MIH) is a qualitative defect of dental enamel characterized by demarcated opacities present in permanent first molars and other teeth. It is considered a major clinical challenge in dentistry because it makes affected teeth more susceptible to fractures and dental caries. Its diagnosis is mainly clinical and there are few technological resources that allow for a more accurate diagnosis, especially with respect to the depth of the defect in the dental enamel. In this context, optical coherence tomography (OCT), which is routinely used in ophthalmology, can produce images of the depth of the dental enamel, making it a promising method. In this study, 33 teeth with different MIH severities were evaluated using OCT and microcomputed tomography (microCT). Semi-quantitative methods of grayscale pattern analysis were used to compare images obtained from different severities of MIH with the mineral density obtained through microCT. MicroCT evaluation revealed that hypomineralized enamel had a significantly lower mineral density than intact enamel. However, this difference was not observed between the mild and severe MIH lesions. In the OCT evaluation, significant differences were observed between the intact and hypomineralized enamel, and the gray value comparison provided a method for quantitative differentiation between the two. This study suggests that OCT could be a useful adjunct to traditional diagnostic methods for MIH, offering a noninvasive approach to evaluate enamel defects. RESEARCH HIGHLIGHTS: Combining optical coherence tomography with grayscale digital analysis shows potential as a promising method for diagnosing molar-incisor hypomineralization and assessing its level of severity.


Assuntos
Hipoplasia do Esmalte Dentário , Esmalte Dentário , Tomografia de Coerência Óptica , Microtomografia por Raio-X , Microtomografia por Raio-X/métodos , Tomografia de Coerência Óptica/métodos , Humanos , Hipoplasia do Esmalte Dentário/diagnóstico por imagem , Hipoplasia do Esmalte Dentário/patologia , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Dente Molar/diagnóstico por imagem , Feminino , Criança , Masculino , Adolescente , Incisivo/diagnóstico por imagem , Hipomineralização Molar
12.
Aust Endod J ; 50(2): 299-308, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38462707

RESUMO

This study aimed to assess the association between genetic polymorphisms in BMP2 (rs1005464 and rs235768), BMP4 (rs17563), SMAD6 (rs2119261 and rs3934908) and RUNX2 (rs59983488 and rs1200425) and pulp stones (PS). A total of 117 participants, consisting of 63 individuals with PS and 54 without PS, were included. Digital radiographs and a demographic/clinical questionnaire were used. Genomic DNA from salivary cells was genotyped via real-time polymerase chain reaction. Statistical analyses, including Chi-Square, Fisher's exact tests, Poisson regression and dimensionality reduction, were conducted. The rs2119261 polymorphism in the SMAD6 gene showed an association with genotype distribution in the recessive model (p = 0.049). The T-T haplotype in the SMAD6 gene (rs2119261 and rs3934908) was more prevalent in the control group and significantly linked with PS (p = 0.029). No associations were found between PS risk and genetic polymorphisms in BMP2, BMP4 and RUNX2. Polymorphisms in the SMAD6 gene were associated with PS.


Assuntos
Proteína Morfogenética Óssea 2 , Proteína Morfogenética Óssea 4 , Subunidade alfa 1 de Fator de Ligação ao Core , Proteína Smad6 , Humanos , Proteína Smad6/genética , Proteína Morfogenética Óssea 4/genética , Subunidade alfa 1 de Fator de Ligação ao Core/genética , Masculino , Feminino , Proteína Morfogenética Óssea 2/genética , Adulto , Polimorfismo de Nucleotídeo Único , Genótipo , Polimorfismo Genético/genética , Adulto Jovem , Estudos de Casos e Controles
13.
Odontology ; 112(4): 1167-1177, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38514512

RESUMO

To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.


Assuntos
Colagem Dentária , Guta-Percha , Teste de Materiais , Microscopia Eletrônica de Varredura , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Guta-Percha/química , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Humanos , Colagem Dentária/métodos , Técnicas In Vitro , Cerâmica/química , Propriedades de Superfície , Dente Canino , Análise do Estresse Dentário , Temperatura
14.
Dement Neuropsychol ; 18: e20230076, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38425701

RESUMO

Infection with the SARS-CoV-2 virus can lead to neurological symptoms in the acute phase and in the Long COVID phase. These symptoms usually involve cognition, sleep, smell disorders, psychiatric manifestations, headache and others. This condition is more commonly described in young adults and women. This symptomatology can follow severe or mild cases of the disease. The importance of this issue resides in the high prevalence of neurological symptoms in the Long COVID phase, which entails significant morbidity in this population. In addition, such a condition is associated with high health care costs, with some estimates hovering around 3.7 trillion US dollars. In this review, we will sequentially describe the current knowledge about the most prevalent neurological symptoms in Long COVID, as well as their pathophysiology and possible biomarkers.


A infecção pelo vírus SARS-CoV-2 pode levar a sintomas neurológicos na fase aguda e na fase de COVID longa. Esses sintomas geralmente envolvem cognição, sono, distúrbios do olfato, manifestações psiquiátricas, dor de cabeça e outros. Esta condição é mais comumente descrita em adultos jovens e mulheres. A sintomatologia pode acompanhar casos graves ou leves da doença. A importância desta questão reside na elevada prevalência de sintomas neurológicos na fase de COVID longa, o que acarreta morbilidade significativa nesta população. Além disso, tal condição está associada a elevados custos de cuidados de saúde, com algumas estimativas em torno de 3,7 trilhões de dólares americanos. Nesta revisão, descrevemos sequencialmente o conhecimento atual sobre os sintomas neurológicos mais prevalentes na COVID longa, bem como sua fisiopatologia e possíveis biomarcadores.

15.
Braz Dent J ; 35: e245678, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537022

RESUMO

To evaluate the impact of genetic polymorphisms in interleukins (IL1A rs17561, rs1304037; IL10 rs1800871; IL1RN rs9005), nitric oxide (NOS2 rs2779249, rs2897518) and suppressor of cytokine signaling (SOCS1 rs243327, rs33977706) on oral health-related quality of life (OHRQoL) of patients under-going root canal treatment (RCT). METHODS: The sample consisted of 108 participants, presenting single-rooted teeth with asymptomatic periapical periodontitis. The impact of the OHRQoL was recorded using the Oral Health Impact Profile (OHIP-14) before, seven, and 30 days after RCT. Saliva samples were collected as a source of genomic DNA. Genetic polymorphisms were genotyped by Real-Time PCR using the Taqman method. Univariate and Multivariate analyses were used (p<0.05). RESULTS: A significant difference was observed for the polymorphism rs2297518 in the NOS2 gene in functional limitation in the codominant (p=0.037) and recessive (p=0.001) models; in the physical pain (p<0.001 in both models); in psychological discomfort (p<0.001 in both models); in physical disability (p<0.001 in both models) and in psychological disability (p<0.001 in both models). Polymorphisms in the SOCS1 gene, in the recessive model, rs33977706 (p=0.045) and rs243327 (p=0.019), influenced the OHRQoL in the psychological discomfort domain. CONCLUSIONS: Polymorphisms in NOS2 and SOCS1 genes influenced the OHRQoL of patients undergoing RCT.


Assuntos
Cavidade Pulpar , Periodontite , Humanos , Saúde Bucal , Polimorfismo Genético , Inquéritos e Questionários , Qualidade de Vida/psicologia
16.
Chronobiol Int ; 41(2): 283-293, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38311937

RESUMO

Changes in circadian rhythms have been observed in patients with chronic kidney disease (CKD), and evidence suggests that these changes can have a negative impact on health. This study aimed to investigate the existence of hemodialysis-induced chronodisruption, the chronotype distribution, and their association with sleep quality and quality of life (QoL). This was a cross-sectional study that enrolled 165 patients (mean age: 51.1 ± 12.5 y, 60.6% male) undergoing hemodialysis from three local units. The following instruments were used: the Morning-Eveningness Questionnaire (MEQ); a modified version of the Munich Chronotype Questionnaire (MCQT) to estimate hemodialysis-induced chronodisruption (HIC); the Kidney Disease QoL Short Form (KDQOL-SF); the Epworth Sleepiness Scale (ESS); the Pittsburgh Sleep Quality Index (PSQI) and the 10-Cognitive Screener (10-CS). HIC was present in 40.6% of CKD patients. Morning chronotype was prevalent in CKD patients (69%) compared to evening-type (17.1%) and significantly different from a paired sample from the general population (p < 0.001). HIC and chronotype were associated with different domains of QoL but not with sleep quality. This study suggests that there is a HIC and that morning chronotype is associated with CKD patients undergoing hemodialysis, with implications for QoL.


Assuntos
Ritmo Circadiano , Insuficiência Renal Crônica , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Sono , Qualidade de Vida , Cronotipo , Estudos Transversais , Inquéritos e Questionários , Insuficiência Renal Crônica/terapia , Diálise Renal
17.
Curr Res Physiol ; 7: 100119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357495

RESUMO

Cajuína is a processed drink derived from cashew and is widely consumed in the northeast region of Brazil. This study evaluated the effect of a cajuína-based hydroelectrolytic drink on the aerobic performance and hydration status of recreational runners. Seventeen males (31.9 ± 1.6 years, 51.0 ± 1.4 ml/kg/min) performed three time-to-exhaustion running sessions on a treadmill at 70% VO2max, ingesting cajuína hydroelectrolytic drink (CJ), high carbohydrate commercial hydroelectrolytic drink (CH) and mineral water (W) every 15 min during the running test. The participants ran 80.3 ± 8.4 min in CJ, 70.3 ± 6.8 min in CH and 71.8 ± 6.9 min in W, with no statistical difference between procedures. Nevertheless, an effect size of η2 = 0.10 (moderate) was observed. No statistical difference was observed in the concentrations of sodium, potassium, and osmolality in both serum and urine between the three conditions. However, the effect size was moderate (urine sodium) and high (serum sodium, potassium, and osmolality). Urine specific gravity, sweating rate and heart rate were not significantly different between drinks. The cajuína-based hydroelectrolytic drink promotes similar effects compared to commercial hydroelectrolytic drink and water, considering specific urine gravity, heart rate, sweating, and time to exhaustion in recreational runners.

18.
Sleep Breath ; 28(3): 1187-1195, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38252255

RESUMO

PURPOSE: To investigate a possible association between the risk of obstructive sleep apnoea (OSA) and disability in individuals with cardiovascular or cerebrovascular diseases. METHODS: Cross-sectional study was conducted with 373 individuals (313 with cardiovascular or cerebrovascular diseases and 60 healthy). Disability was assessed by the 12-item World Health Organization Disability Assessment Schedule (WHODAS), and the risk of OSA was assessed by STOP-BANG. Anxiety and depression symptoms, daytime sleepiness, and cognition were assessed by the Hospital Anxiety and Depression Scale (HADS), Epworth Sleepiness Scale (ESS), and Mini Mental State Examination (MMSE). RESULTS: Greater disability was found in individuals with intermediate or high risk of OSA, considering healthy individuals (p=0.03), or individuals diagnosed with arrhythmia (p<0.01) or coronary artery disease (p=0.04). A high risk of OSA and higher WHODAS scores was significant among women as well as between OSA risk categories (p<0.01). Cognitive deficit and level of education also showed differences between OSA risk categories. Age, depression, and sleepiness were also associated with the subjects' disability (p<0.01). Gamma regression model showed higher WHODAS scores in female, in those with intermediate and high risk of OSA, and in those with depressive symptoms and cognitive deficit. Age also showed a correlation with higher WHODAS scores. The presence of all investigated cardio and cerebrovascular diseases showed an increase in the WHODAS score, implying a greater disability compared to healthy individuals. CONCLUSION: Moderate and high risk of OSA is associated with disability, as well as gender, age, depressive symptoms, cognitive deficit, and cardiovascular diseases.


Assuntos
Doenças Cardiovasculares , Transtornos Cerebrovasculares , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Transversais , Doenças Cardiovasculares/epidemiologia , Transtornos Cerebrovasculares/epidemiologia , Idoso , Avaliação da Deficiência , Adulto , Fatores de Risco , Comorbidade
19.
J Mech Behav Biomed Mater ; 151: 106400, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262184

RESUMO

AIM: To mensure the physicochemical properties of three ceramic cement endodontic sealers AH Plus Bioceramic, Bio-C Sealer and Bio-C Sealer Ion+ with an epoxy resin sealer, AH Plus. MATERIAL AND METHODS: These properties were measured: hardening time (HT), dimensional change (DC), solubility (SL), flow (FL) and radiopacity (RD). The distilled water obtained from the SL test was analyzed with atomic absorption spectrometry. A sample calculation was made considering n = 5 repetitions for each experimental sealer evaluated. Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests (p < 0.05). RESULTS: For the HT, AH Plus (484 ± 2.76 min) and AH Plus Bioceramic (424 ± 1.23 min) set more slowly than of Bio-C Sealer (370 ± 4.50 min) and Bio-C Sealer Ion+ (380 ± 1.42 min) (p < 0.05). AH Plus Bioceramic (12.56 ± 2.71 %) was more soluble than Bio-C Sealer (6.69 ± 1.67 %), Bio-C Sealer Ion+ (5.67 ± 2.16 %) and AH Plus (0.15 ± 0.01 %) (p < 0.05). AH Plus (0.03 ± 0.01 %) had slight expansion while the cement-based sealers had shrinkage: AH Plus Bioceramic (-1.60 ± 0.63 %) and Bio-C Sealer (-1.38 ± 0.69 %), Bio-C Sealer Ion+ (-5.19 ± 1.23 %) (p < 0.05). Bio-C Sealer Ion+ (59.80 ± 0.86 mm) and Bio-C Sealer (58.60 ± 0.98 mm) had the highest flow compared with AH Plus (56.90 ± 0.56 mm) and AH Plus Bioceramic (49.50 ± 0.63 mm) (p < 0.05). AH Plus (9.17 ± 0.06 mmAl) and AH Plus Bioceramic (8.27 ± 0.84 mmAl) showed radiopacity values when compared with those of Bio-C Sealer (4.90 ± 0.08 mmAl) and Bio-C Sealer Ion+ (4.14 ± 0.05 mmAl) (p > 0.05). CONCLUSION: Ion release is inhered to these cement-based sealers and this result in calcium ion release.


Assuntos
Cálcio , Materiais Restauradores do Canal Radicular , Cálcio/química , Materiais Restauradores do Canal Radicular/química , Compostos de Cálcio/química , Resinas Epóxi/química , Silicatos/química , Teste de Materiais
20.
Enferm. foco (Brasília) ; 15(1,n.esp): 1-6, jan. 2024.
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1531595

RESUMO

Trata de nota técnica sobre Práticas Avançadas de Enfermagem (PAE) no Brasil, elaborada por comissão e submetida à aprovação do plenário do Conselho Federal de Enfermagem (Cofen). O documento aborda conceitos, ações, implementação e regulação das práticas avançadas de Enfermagem, expandindo os limites do escopo da atuação do enfermeiro e reforçando a sua prática clínica. (AU)


This is a technical note on Advanced Nursing Practices (ANP) in Brazil, prepared by a committee and submitted for approval by the plenary of the Federal Nursing Council (Cofen). The document addresses concepts, actions, implementation and regulation of advanced nursing practices, expanding the limits of the scope of nurses' work and reinforcing their clinical practice. (AU)


Esta es una nota técnica sobre las Prácticas Avanzadas de Enfermería (PAE) en Brasil, elaborada por un comité y sometida a la aprobación del plenario del Consejo Federal de Enfermería (Cofen). El documento aborda los conceptos, acciones, implementación y reglamentación de las prácticas avanzadas de enfermería, ampliando los límites del ámbito de actuación de las enfermeras y reforzando su práctica clínica. (AU)


Assuntos
Enfermagem , Estratégias de Saúde Globais , Regulação e Fiscalização em Saúde , Prática Avançada de Enfermagem , Padrões de Prática em Enfermagem , Estratégias para Cobertura Universal de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA