Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EuroIntervention ; 17(12): e1033-e1040, 2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34219662

RESUMO

BACKGROUND: Residual peri-device leakage (PDL) is frequent after left atrial appendage occlusion (LAAO). Little is known about management strategies, procedural aspects and outcomes of interventional PDL closure. AIMS: The aim of this study was to assess the safety and feasibility of PDL closure after LAAO. METHODS: Fifteen centres contributed data on baseline characteristics, in-hospital and follow-up outcomes of patients who underwent PDL closure after LAAO. Outcomes of interest included acute success and complication rates and long-term efficacy of the procedure. RESULTS: A total of 95 patients were included and a cumulative number of 104 leaks were closed. The majority of PDLs were detected within 90 days (range 41-231). Detachable coils were the most frequent approach (42.3%), followed by the use of the AMPLATZER Vascular Plug II (29.8%) and the AMPLATZER Duct Occluder II (17.3%). Technical success was 100% with 94.2% of devices placed successfully within the first attempt. There were no major complications requiring surgical or transcatheter interventions. During follow-up (96 days [range 49-526]), persistent leaks were found in 18 patients (18.9%), yielding a functional success rate of 82.7%, although PDLs were significantly reduced in size (pre-leak sizemax: 6.1±3.6 mm vs post-leak sizemax: 2.5±1.3 mm, p<0.001). None of the patients had a leak >5 mm. Major adverse events during follow-up occurred in 5 patients (2 ischaemic strokes, 2 intracranial haemorrhages, and 1 major gastrointestinal bleeding). CONCLUSIONS: Several interventional techniques have become available to achieve PDL closure. They are associated with high technical and functional success and low complication rates.


Assuntos
Dispositivo para Oclusão Septal , Estudos de Viabilidade , Humanos , Dispositivo para Oclusão Septal/efeitos adversos
2.
J Intensive Care Soc ; 17(1): 51-62, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28979458

RESUMO

PURPOSE: Systolic impairment is well reported in critically ill patients but diastolic function has been relatively understudied. The objective of this review was to assess tissue Doppler indices of diastolic function in critically ill patients along with any association with mortality. METHODS: A systematic review of articles in English using Medline, EMBASE, CINAHL and the Cochrane database of systematic reviews. Search terms included diastolic function, diastolic dysfunction, diastolic abnormal*, diastolic heart failure, diastolic filling, ventricular relaxation, pulmonary artery occlusion pressure, left ventricular filling pressure, cardiac dysfunction, intensive care, critical care, critically ill, critical illness, sepsis and septic shock. Only studies of critically ill adult patients (excluding post-cardiac surgical patients) whose diastolic function was assessed using tissue Doppler imaging were included. Study quality was assessed using a modified version of the Newcastle-Ottawa Scale (NOS). RESULTS: Nineteen studies were included, with a total of 1365 patients. All trials were observational. There was a large heterogeneity in patient populations and the methodology of tissue Doppler assessment of diastology resulting in a descriptive analysis. Patient groups included severe sepsis or septic shock (5 studies), septic shock (5 studies), systemic inflammatory response syndrome and shock (1 study), septic shock and acute lung injury (1 study), cancer and septic shock (2 studies), general ICU patients (1 study), combined medical and surgical ICU (2 studies) and sub-arachnoid haemorrhage patients (2 studies). Seventeen studies scored 5/6 on the NOS with the remaining two scoring 4/6. Fourteen studies reported on numbers of patients diagnosed with diastolic dysfunction (500/999, mean 50%, range 20-92%). Three studies found that diastolic dysfunction was an independent predictor of mortality. CONCLUSIONS: Current data shows a large range in the incidence of diastolic dysfunction in this patient population and a variable link with mortality. Future research should focus on the definition of normal values for diastolic function in critically ill patients along with the effects of ICU therapies and consensus criteria for its assessment in this patient population.

3.
Eur Heart J Cardiovasc Imaging ; 15(7): 817-27, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24699322

RESUMO

BACKGROUND: Variability has been described between different echo machines and different modalities when measuring tissue velocities. We assessed the consistency of tissue velocity measurements across different modalities and different manufacturers in an in vitro model and in patients. Furthermore, we present freely available software tools to repeat these evaluations. METHODS AND RESULTS: We constructed a simple setup to generate reproducible motion and used it to compare velocities measured using three echocardiographic modalities: M-mode, speckle tracking, and tissue Doppler, with a straightforward, non-ultrasound, optical gold standard. In the clinical phase, 25 patients underwent M-mode, speckle tracking, and tissue Doppler measurements of s', e', and a' velocities. In vitro, the M-mode and speckle tracking velocities agreed with optical assessment. Of the three possible tissue Doppler measurement conventions (outer, middle, and inner edge) only the middle agreed with optical assessment (discrepancy -0.20 (95% CI -0.44 to 0.03) cm/s, P = 0.11, outer +5.19 (4.65 to 5.73) cm/s, P < 0.0001, inner -6.26 (-6.87 to -5.65) cm/s, P < 0.0001). A similar pattern occurred across all four studied manufacturers. M-mode was therefore chosen as the in vivo gold standard. Clinical measurements of s' velocities by speckle tracking and the middle line of the tissue Doppler showed concordance with M-mode, while the outer line overestimated significantly (+1.27(0.96 to 1.59) cm/s, P < 0.0001) and the inner line underestimated (-1.82 (-2.11 to -1.52) cm/s, P < 0.0001). CONCLUSIONS: Echocardiographic velocity measurements can be more consistent than previously suspected. The statistically modal velocity, found at the centre of the spectral pulsed wave tissue Doppler envelope, most closely represents true tissue velocity. This article includes downloadable, vendor-independent software enabling calibration of echocardiographic machines using a simple, inexpensive in vitro setup.


Assuntos
Ecocardiografia Doppler de Pulso/métodos , Ecocardiografia Doppler de Pulso/normas , Guias como Assunto , Processamento de Imagem Assistida por Computador , Fluxometria por Laser-Doppler/normas , Imagens de Fantasmas , Idoso , Análise de Variância , Velocidade do Fluxo Sanguíneo , Calibragem , Feminino , Humanos , Fluxometria por Laser-Doppler/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos de Amostragem , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...