Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Microbiol Infect ; 25(3): 372-378, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29906597

RESUMO

OBJECTIVES: Automated point-of-care molecular assays have greatly shortened the turnaround time of respiratory virus testing. One of the major bottlenecks now lies at the specimen collection step, especially in a busy clinical setting. Saliva is a convenient specimen type that can be provided easily by adult patients. This study assessed the diagnostic validity, specimen collection time and cost associated with the use of saliva. METHODS: This was a prospective diagnostic validity study comparing the detection rate of respiratory viruses between saliva and nasopharyngeal aspirate (NPA) among adult hospitalized patients using Xpert® Xpress Flu/RSV. The cost and time associated with the collection of saliva and nasopharyngeal specimens were also estimated. RESULTS: Between July and October 2017, 214 patients were recruited. The overall agreement between saliva and NPA was 93.3% (196/210, κ 0.851, 95% CI 0.776-0.926). There was no significant difference in the detection rate of respiratory viruses between saliva and NPA (32.9% (69/210) versus 35.7% (75/210); p 0.146). The overall sensitivity and specificity were 90.8% (81.9%-96.2%) and 100% (97.3%-100%), respectively, for saliva, and were 96.1% (88.9%-99.2%) and 98.5% (94.7%-99.8%), respectively, for NPA. The time and cost associated with the collection of saliva were 2.26-fold and 2.59-fold lower, respectively, than those of NPA. CONCLUSIONS: Saliva specimens have high sensitivity and specificity in the detection of respiratory viruses by an automated multiplex Clinical Laboratory Improvement Amendments-waived point-of-care molecular assay when compared with those of NPA. The use of saliva also reduces the time and cost associated with specimen collection.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Testes Imediatos , Infecções Respiratórias/diagnóstico , Manejo de Espécimes/métodos , Idoso , Idoso de 80 Anos ou mais , Custos e Análise de Custo , Feminino , Humanos , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Masculino , Pessoa de Meia-Idade , Técnicas de Diagnóstico Molecular/normas , Nasofaringe/virologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Vírus Sinciciais Respiratórios/isolamento & purificação , Infecções Respiratórias/virologia , Saliva/virologia , Sensibilidade e Especificidade , Manejo de Espécimes/economia , Fatores de Tempo
3.
J Glaucoma ; 13(6): 479-85, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15534473

RESUMO

PURPOSE: To evaluate the effect of varying the scanning resolution of optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) measurement on diagnostic sensitivity and functional correlation in glaucoma. PATIENTS AND METHODS: 314 eyes from 182 subjects including 107 normal eyes, 83 glaucoma suspect eyes, and 124 glaucoma eyes were included in this cross-sectional study. Standard automated perimetry and OCT measurement of RNFL thickness were performed. Each individual underwent two scanning protocols: (1) fast RNFL thickness (3.4) scan (with resolution of 256 scan points) and (2) RNFL thickness (3.4) scan (with resolution of 512 scan points). RNFL thickness was compared among the groups. Diagnostic sensitivity was evaluated with Receiver Operating Characteristic (ROC) Curve. Relationship between RNFL thickness and visual field mean deviation was examined using linear regression analysis. RESULTS: Measured RNFL thickness using fast RNFL thickness (3.4) scan was significantly higher compared with RNFL thickness (3.4) scan in average, superior, nasal and inferior RNFL in all diagnostic groups. Comparing normal and glaucoma groups, RNFL thickness (3.4) scan produced the largest area under the ROC curve (0.912) based on average RNFL thickness. A stronger correlation between average RNFL and visual field mean deviation was found in RNFL thickness (3.4) scan (R = 0.75, R = 0.56). CONCLUSIONS: Higher resolution RNFL scan provides better diagnostic sensitivity in glaucoma detection and a stronger correlation with visual function.


Assuntos
Glaucoma/diagnóstico , Fibras Nervosas/ultraestrutura , Retina/ultraestrutura , Tomografia de Coerência Óptica/normas , Adulto , Estudos de Casos e Controles , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Campos Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...