Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int J Surg ; 102: 106094, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35662438

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) is subject to different management approaches and guidelines according to Eastern and Western therapeutic algorithms. Use of selective internal radiation therapy (SIRT) with resin yttrium 90 microspheres for HCC has increased in Asia in recent years, without clearly defined indications for its optimal application. The objective of this systematic review and expert consensus statement is to provide guidance and perspectives on the use of SIRT among patients with HCC in Asia. MATERIALS AND METHODS: A systematic literature review identified current publications on HCC management and SIRT recommendations. A group of 10 experts, representing stakeholder specialties and countries, convened between August 2020 and March 2021 and implemented a modified Delphi consensus approach to develop guidelines and indications for use of SIRT for HCC in Asia. Final recommendations were organized and adjudicated based on the level of evidence and strength of recommendation, per approaches outlined by the American College of Cardiology/American Heart Association and Oxford Centre for Evidence-Based Medicine. RESULTS: The experts acknowledged a general lack of evidence relating to use of SIRT in Asia and identified as an unmet need the lack of phase 3 randomized trials comparing clinical outcomes and survival following SIRT versus other therapies for HCC. Through an iterative process, the expert group explored areas of clinical relevance and generated 31 guidance statements and a patient management algorithm that achieved consensus. CONCLUSION: These recommendations aim to support clinicians in their decision-making and to help them identify and treat patients with HCC using SIRT in Asia. The recommendations also highlight areas in which further clinical trials are needed to define the role of SIRT in management of HCC among Asian populations.


Assuntos
Braquiterapia , Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Microesferas , Radioisótopos de Ítrio/uso terapêutico
3.
BMJ Case Rep ; 14(9)2021 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-34531241

RESUMO

We report a pair of siblings who developed multisystem inflammatory syndrome in children (MIS-C) in close temporal proximity after recent exposure to SARS-CoV-2. Both siblings presented with Kawasaki disease-like features and haemodynamic instability, with the onset of symptoms within 6 days of each other. Remarkably, one of the siblings was the elder of a pair of monozygotic twins. The younger monozygotic twin, however, did not develop MIS-C.


Assuntos
COVID-19 , Idoso , Criança , Humanos , SARS-CoV-2 , Irmãos , Síndrome de Resposta Inflamatória Sistêmica
4.
BMJ Case Rep ; 14(5)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34059550

RESUMO

We report a case of COVID-19 in a 29-week preterm infant. This child is the youngest reported case of SARS-CoV-2 infection in Malaysia, and to the best of our knowledge, one of the youngest documented cases of established vertical transmission of SARS-CoV-2 reported in literature. Our report highlights the clinical course, timelines of viral shedding by real-time reverse transcription-PCR and antibody seroconversion in a premature infant infected with SARS-CoV-2. In addition, we discuss the challenges faced in managing a preterm infant infected with SARS-CoV-2 and the knowledge gaps that need to be explored.


Assuntos
COVID-19 , Criança , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Malásia , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2
9.
Ann Acad Med Singap ; 45(5): 191-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27383718

RESUMO

INTRODUCTION: A paradigm shift appears to have occurred worldwide in surgery for primary hyperparathyroidism with the advent of sensitive preoperative imaging techniques. Preoperative imaging for parathyroid adenoma localisation was not found to be useful in a study conducted in Singapore in the 1990s. This study aimed to explore what the change has been in preoperative localisation tools compared to the previous study and if the ability of these tools to correctly localise pathologic parathyroid glands has improved. MATERIALS AND METHODS: A retrospective review of patients who had surgery for primary hyperparathyroidism at our institution during the period 2005 to 2014 was carried out. Individuals with positive, as opposed to those with negative preoperative imaging, were compared with regard to whether they underwent limited focal or bilateral neck exploration. Length of hospital stay (LOHS) was also compared between patients who underwent limited versus bilateral exploration. RESULTS: Fifty-eight patients who had preoperative imaging and surgery were evaluated. True positive rates of sestamibi, ultrasound and 4-dimensional (4D) computed tomography (CT) scans were 63.8%, 72.4% and 90%, respectively. Eighty percent of patients who had positive localisation had limited exploration. LOHS was 2.8 days (1.6, 4.8) and 4.3 days (2.1, 9.0) for limited and bilateral exploration respectively, P = 0.011. CONCLUSION: Our study highlights the marked change in the surgical landscape for primary hyperparathyroidism in the last 2 decades in Singapore. Improved preoperative localisation has resulted in a swing from predominantly bilateral, to limited exploration in almost all cases of primary hyperparathyroidism due to solitary adenoma. LOHS was significantly shorter in patients who had limited as compared to those who had bilateral exploration.


Assuntos
Adenoma/diagnóstico por imagem , Hiperparatireoidismo Primário/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Adenoma/cirurgia , Tomografia Computadorizada Quadridimensional , Humanos , Hiperparatireoidismo Primário/cirurgia , Tempo de Internação , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia , Padrões de Prática Médica , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Singapura , Tecnécio Tc 99m Sestamibi , Ultrassonografia
10.
Int J Clin Exp Pathol ; 8(6): 7506-17, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26261662

RESUMO

Phosphaturic mesenchymal tumour mixed connective tissue variant (PMTMCT) is a rare tumour occurring in bone and soft tissue that usually behaves in a benign manner. Elaboration of biologically active substances by this tumour gives rise to a paraneoplastic syndrome known as oncogenic osteomalacia, manifesting clinically as bone pain, generalized weakness and pathological fractures. Recognition of PMTMCT and its associated syndrome is important, as resection of the tumour in most instances results in prompt resolution of symptoms. Previously reported cases of this tumour have emphasized the consistent presence of certain histological features that are considered prerequisite for making the diagnosis of PMTMCT. We describe three cases of PMTMCT, of which two first presented with progressive symptoms of osteomalacia and one remained clinically silent aside from the symptom of a palpable lump. Our cases highlight the wide-ranging histological patterns displayed by these tumours, and draw attention to certain microscopic findings that until now have been given little if any mention. Tentacular growth pattern and satellite nodules appear to be common findings in PMTMCTs, and can make complete surgical excision of these tumours challenging. The ability of this otherwise histologically benign tumour to permeate vascular spaces has to our knowledge never been described previously. One tumour lacked the characteristic calcifying matrix of PMTMCT, suggesting that in some tumours this defining feature may be focal if not entirely absent. PMTMCT shares features with and can resemble a variety of bone and soft tissue neoplasms, requiring the surgical pathologist to be familiar with this entity.


Assuntos
Mesoderma/patologia , Neoplasias de Tecido Conjuntivo/patologia , Neoplasias de Tecidos Moles/patologia , Adulto , Biomarcadores Tumorais/análise , Biópsia , Feminino , Humanos , Imuno-Histoquímica , Masculino , Mesoderma/química , Pessoa de Meia-Idade , Neoplasias de Tecido Conjuntivo/química , Neoplasias de Tecido Conjuntivo/complicações , Neoplasias de Tecido Conjuntivo/cirurgia , Osteomalacia , Síndromes Paraneoplásicas/etiologia , Tomografia por Emissão de Pósitrons , Neoplasias de Tecidos Moles/química , Neoplasias de Tecidos Moles/complicações , Neoplasias de Tecidos Moles/cirurgia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
EJNMMI Res ; 4: 33, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25024931

RESUMO

BACKGROUND: For yttrium-90 ((90)Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry using technetium-99m ((99m)Tc) macroaggregated albumin (MAA) single photon emission computed tomography with integrated CT (SPECT/CT) of the lung as part of our routine dosimetric protocol for (90)Y radioembolization. Its rationales are the technical superiority of SPECT/CT over planar scintigraphy, ease and convenience of lung auto-segmentation CT densitovolumetry, and dosimetric advantage of patient-specific lung parenchyma masses. METHODS: This is a retrospective study of our pulmonary clinical outcomes and comparison of lung dosimetric accuracy and precision by (99m)Tc MAA SPECT/CT versus conventional planar methodology. (90)Y resin microspheres (SIR-Spheres) were used for radioembolization. Diagnostic CT densitovolumetry was used as a reference for lung parenchyma mass. Pulmonary outcomes were based on follow-up diagnostic CT chest or X-ray. RESULTS: Thirty patients were analyzed. The mean lung parenchyma mass of our Southeast Asian cohort was 822 ± 103 g standard deviation (95% confidence interval 785 to 859 g). Patient-specific lung parenchyma mass estimation by CT densitovolumetry on (99m)Tc MAA SPECT/CT is accurate (bias -21.7 g) and moderately precise (95% limits of agreement -194.6 to +151.2 g). Lung mean radiation absorbed doses calculated by (99m)Tc MAA SPECT/CT and planar methodology are both accurate (bias <0.5 Gy), but (99m)Tc MAA SPECT/CT offers better precision over planar methodology (95% limits of agreement -1.76 to +2.40 Gy versus -3.48 to +3.31 Gy, respectively). None developed radiomicrosphere pneumonitis when treated up to a lung mean radiation absorbed dose of 18 Gy at a median follow-up of 4.4 months. CONCLUSIONS: Personalized predictive lung dosimetry by (99m)Tc MAA SPECT/CT is clinically feasible, safe, and more precise than conventional planar methodology for (90)Y radioembolization radiation planning.

12.
EJNMMI Res ; 3(1): 56, 2013 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-23883566

RESUMO

BACKGROUND: Yttrium-90 (90Y) positron emission tomography with integrated computed tomography (PET/CT) represents a technological leap from 90Y bremsstrahlung single-photon emission computed tomography with integrated computed tomography (SPECT/CT) by coincidence imaging of low abundance internal pair production. Encouraged by favorable early experiences, we implemented post-radioembolization 90Y PET/CT as an adjunct to 90Y bremsstrahlung SPECT/CT in diagnostic reporting. METHODS: This is a retrospective review of all paired 90Y PET/CT and 90Y bremsstrahlung SPECT/CT scans over a 1-year period. We compared image resolution, ability to confirm technical success, detection of non-target activity, and providing conclusive information about 90Y activity within targeted tumor vascular thrombosis. 90Y resin microspheres were used. 90Y PET/CT was performed on a conventional time-of-flight lutetium-yttrium-oxyorthosilicate scanner with minor modifications to acquisition and reconstruction parameters. Specific findings on 90Y PET/CT were corroborated by 90Y bremsstrahlung SPECT/CT, 99mTc macroaggregated albumin SPECT/CT, follow-up diagnostic imaging or review of clinical records. RESULTS: Diagnostic reporting recommendations were developed from our collective experience across 44 paired scans. Emphasis on the continuity of care improved overall diagnostic accuracy and reporting confidence of the operator. With proper technique, the presence of background noise did not pose a problem for diagnostic reporting. A counter-intuitive but effective technique of detecting non-target activity is proposed, based on the pattern of activity and its relation to underlying anatomy, instead of its visual intensity. In a sub-analysis of 23 patients with a median follow-up of 5.4 months, 90Y PET/CT consistently outperformed 90Y bremsstrahlung SPECT/CT in all aspects of qualitative analysis, including assessment for non-target activity and tumor vascular thrombosis. Parts of viscera closely adjacent to the liver remain challenging for non-target activity detection, compounded by a tendency for mis-registration. CONCLUSIONS: Adherence to proper diagnostic reporting technique and emphasis on continuity of care are vital to the clinical utility of post-radioembolization 90Y PET/CT. 90Y PET/CT is superior to 90Y bremsstrahlung SPECT/CT for the assessment of target and non-target activity.

13.
EJNMMI Res ; 3(1): 57, 2013 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-23885971

RESUMO

BACKGROUND: Coincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated albumin (MAA) single-photon emission computed tomography with integrated CT (SPECT/CT) predictive dosimetry. METHODS: Retrospective dose quantification of 90Y resin microspheres was performed on the same 23-patient data set in part 1. Phantom studies were performed to assure quantitative accuracy of our time-of-flight lutetium-yttrium-oxyorthosilicate system. Dose-responses were analyzed using 90Y dose-volume histograms (DVHs) by PET voxel dosimetry or mean absorbed doses by Medical Internal Radiation Dose macrodosimetry, correlated to follow-up imaging or clinical findings. Intended tumor mean doses by predictive dosimetry were compared to doses by 90Y PET. RESULTS: Phantom studies demonstrated near-perfect detector linearity and high tumor quantitative accuracy. For hepatocellular carcinomas, complete responses were generally achieved at D70 > 100 Gy (D70, minimum dose to 70% tumor volume), whereas incomplete responses were generally at D70 < 100 Gy; smaller tumors (<80 cm3) achieved D70 > 100 Gy more easily than larger tumors. There was complete response in a cholangiocarcinoma at D70 90 Gy and partial response in an adrenal gastrointestinal stromal tumor metastasis at D70 53 Gy. In two patients, a mean dose of 18 Gy to the stomach was asymptomatic, 49 Gy caused gastritis, 65 Gy caused ulceration, and 53 Gy caused duodenitis. In one patient, a bilateral kidney mean dose of 9 Gy (V20 8%) did not cause clinically relevant nephrotoxicity. Under near-ideal dosimetric conditions, there was excellent correlation between intended tumor mean doses by predictive dosimetry and those by 90Y PET, with a low median relative error of +3.8% (95% confidence interval, -1.2% to +13.2%). CONCLUSIONS: Tumor and non-target tissue absorbed dose quantification by 90Y PET is accurate and yields radiobiologically meaningful dose-response information to guide adjuvant or mitigative action. Tumor 99mTc MAA SPECT/CT predictive dosimetry is feasible. 90Y DVHs may guide future techniques in predictive dosimetry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...