Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Data ; 11(1): 664, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909069

RESUMO

This research presents a dataset consisting of electroencephalogram and eye tracking recordings obtained from six patients with amyotrophic lateral sclerosis (ALS) in a locked-in state and one hundred seventy healthy individuals. The ALS patients exhibited varying degrees of disease progression, ranging from partial mobility and weakened speech to complete paralysis and loss of speech. Despite these physical impairments, the ALS patients retained good eye function, which allowed them to use a virtual keyboard for communication. Data from ALS patients was recorded multiple times at their homes, while data from healthy individuals was recorded once in a laboratory setting. For each data recording, the experimental design involved nine recording sessions per participant, each corresponding to a common human action or demand. This dataset can serve as a valuable benchmark for several applications, such as improving spelling systems with brain-computer interfaces, investigating motor imagination, exploring motor cortex function, monitoring motor impairment progress in patients undergoing rehabilitation, and studying the effects of ALS on cognitive and motor processes.


Assuntos
Esclerose Lateral Amiotrófica , Interfaces Cérebro-Computador , Eletroencefalografia , Tecnologia de Rastreamento Ocular , Humanos , Esclerose Lateral Amiotrófica/fisiopatologia
2.
J Anal Methods Chem ; 2019: 2952075, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31871819

RESUMO

The simultaneous determination of betamethasone, dexchlorpheniramine maleate, and sodium benzoate in pharmaceutical syrup was done by using a simple validated HPLC method. The chromatographic separation of the three analytes was done in a C18 column maintained at 25°C, using a mixture of acetonitrile and 0.02 M phosphate buffer solution pH 2.70 (35 : 65, v : v) as mobile phase. The isocratic elution was chosen with total flow rate of mobile phase maintained at 1.0 mL per minute. The analytes were detected by a UV-Vis detector set at 254 nm. Injection volume was set at 50 µl. The method was fully validated in terms of specificity, linearity, precision, accuracy, and robustness according to requirements of current guidelines and was proven to be suitable for the intended application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...