Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(12)2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38928636

RESUMO

The present study focuses on establishing the quality assurance of laboratories for recent infections (RTRI) in Thailand. We developed a cold-chain independent method, using fully characterized plasma obtained from the Thai Red Cross Society, and prepared as dried tube specimens (DTS). Twenty microliters of HIV-seronegative, recent, and long-term infected samples were aliquoted into individual tubes and dried at room temperature, 20-30 degrees Celsius, in a biosafety cabinet overnight to ensure optimal preservation. The DTS external quality control and external quality assessment were tested for homogeneity and stability following the ISO/Guide 35 guidelines. The DTS panels were distributed to 48 sites (FY 2022) and 27 sites (FY 2023) across 14 and 9 provinces, respectively, in Thailand. The results from participating laboratories were collected and evaluated for performance. The results were scored, and acceptable performance criteria were defined as the proportion of panels correctly tested, which was set at 100%. The satisfactory performance ranged from 96% to 100% and was not significantly different among the 13 health regions. The developed and implemented DTS panels can be used to monitor the quality of RTRI testing in Thailand.

2.
Pract Lab Med ; 31: e00288, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35814312

RESUMO

Background: Thailand National External Quality Assessment Scheme (NEQAS) for HbA1c was established to evaluate the quality of HbA1c assays in Thailand in 2016. Methods: HbA1c results from participating laboratories were compared to the target value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference system. Results: The pass rates of participating laboratories during 2016-2020 were72-88%. The mean bias ranged between -0.19 and 0.20% of HbA1c. SD ranged from 0.30 to 1.08% of HbA1c. The overall coefficients of variation ranged from 4.46-15.66%. Conclusions: Performance evaluation using IFCC assigned values indicated that different assay methods had an effect on HbA1c results. Participation in external quality assessment programs for HbA1c analysis is essential for improving laboratory quality and benefiting patient management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...