Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Neuroimage ; 28(3): 720-37, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16150610

RESUMO

The combination of functional magnetic resonance imaging (FMRI) and electroencephalography (EEG) has received much recent attention, since it potentially offers a new tool for neuroscientists that makes simultaneous use of the strengths of the two modalities. However, EEG data collected in such experiments suffer from two kinds of artifact. First, gradient artifacts are caused by the switching of magnetic gradients during FMRI. Second, ballistocardiographic (BCG) artifacts related to cardiac activities further contaminate the EEG data. Here we present new methods to remove both kinds of artifact. The methods are based primarily on the idea that temporal variations in the artifacts can be captured by performing temporal principal component analysis (PCA), which leads to the identification of a set of basis functions which describe the temporal variations in the artifacts. These basis functions are then fitted to, and subtracted from, EEG data to produce artifact-free results. In addition, we also describe a robust algorithm for the accurate detection of heart beat peaks from poor quality electrocardiographic (ECG) data that are collected for the purpose of BCG artifact removal. The methods are tested and are shown to give superior results to existing methods. The methods also demonstrate the feasibility of simultaneous EEG/FMRI experiments using the relatively low EEG sampling frequency of 2048 Hz.


Assuntos
Artefatos , Eletroencefalografia/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Algoritmos , Eletrocardiografia , Potenciais Evocados/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Lasers , Análise de Componente Principal , Reprodutibilidade dos Testes
2.
Neuroimage ; 28(3): 708-19, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16112589

RESUMO

Simultaneous recording of event-related electroencephalographic (EEG) and functional magnetic resonance imaging (fMRI) responses has the potential to provide information on how the human brain reacts to an external stimulus with unique spatial and temporal resolution. However, in most studies combining the two techniques, the acquisition of functional MR images has been interleaved with the recording of evoked potentials. In this study we investigated the feasibility of recording pain-related evoked potentials during continuous and simultaneous collection of blood oxygen level-dependent (BOLD) functional MR images at 3 T. Brain potentials were elicited by selective stimulation of cutaneous Adelta and C nociceptors using brief radiant laser pulses (laser-evoked potentials, LEPs). MR-induced artifacts on EEG data were removed using a novel algorithm. Latencies, amplitudes, and scalp distribution of LEPs recorded during fMRI were not significantly different from those recorded in a control session outside of the MR scanner using the same equipment and experimental design. Stability tests confirmed that MR-image quality was not impaired by the evoked potential recording, beyond signal loss related to magnetic susceptibility differences local to the electrodes. fMRI results were consistent with our previous studies of brain activity in response to nociceptive stimulation. These results demonstrate the feasibility of recording reliable pain-related LEPs and fMRI responses simultaneously. Because LEPs collected during fMRI and those collected in a control session show remarkable similarity, for many experimental designs the integration of LEP and fMRI data collected in separate, single-modality acquisitions may be appropriate. Truly simultaneous recording of LEPs and fMRI is still desirable in specific experimental conditions, such as single-trial, learning, and pharmacological studies.


Assuntos
Encéfalo/fisiopatologia , Eletroencefalografia , Imageamento por Ressonância Magnética , Dor/fisiopatologia , Adulto , Algoritmos , Artefatos , Potenciais Evocados/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lasers , Masculino , Oxigênio/sangue , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA