Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foods ; 13(11)2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38890888

RESUMO

The post-harvest processing of coffee beans leads to a wide range of reactions involving proteins. The formation of crosslinks between proteins and phenolic compounds present in high concentrations of coffee beans represents one of the most challenging and still not fully characterized reactions. The aim of this work was to assess the presence of products from such reactions in coffee samples, focusing on the adducts between cysteine and chlorogenic acids (CQAs). For this purpose, 19 green and 15 roasted coffee samples of the Coffea arabica, Coffea canephora, and Coffea liberica varieties were selected for this study and basically characterized. Then, targeted liquid chromatography mass spectrometry (LC-MS/MS) methods were developed to assess the formation of adducts between CQA and cysteine, glutathione, and N-acetylcysteine as the amino acid and peptide models, and quantified such adducts in coffee samples. The results of the characterization showed a heterogeneous distribution of the protein content (8.7-14.6%), caffeine (0.57-2.62 g/100 g), and antioxidant capacity (2-4.5 g ascorbic acid/100 g) in Arabica, Canephora, and Liberica samples. Glutamic acid, arginine, and proline were found to be the major amino acids, while 5-CQA (38-76%), 3-CQA (4-13%), and 4-CQA (4-13%) were the most abundant CQA derivatives of all coffee varieties. The model experiments for adduct formation demonstrated that cysteine binds to CQA via thiol groups and 5-CQA initially isomerizes to 3- and 4-CQA, depending on the conditions, allowing cysteine to bind to two different sites on 3-, 4- or 5-CQA molecules, thus, forming six different Cys-CQA adducts with m/z 476. The reaction was more favored at pH 9, and the adducts proved to be stable up to 90 °C for 10 min and up to 28 days at room temperature. The relative quantification of adducts showed peak area values ranging from 1100 to 3000 in green coffee bean samples, while no adducts were detected in roasted coffee beans. Overall, this work was the first attempt to demonstrate the presence of Cys-CQA adducts in coffee beans and paves the way for further investigations of such adduct formation at the protein level.

2.
J Appl Lab Med ; 8(4): 726-741, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37222567

RESUMO

BACKGROUND: Throughout the COVID-19 pandemic, veterinary diagnostic laboratories have tested diagnostic samples for SARS-CoV-2 both in animals and over 6 million human samples. An evaluation of the performance of those laboratories is needed using blinded test samples to ensure that laboratories report reliable data to the public. This interlaboratory comparison exercise (ILC3) builds on 2 prior exercises to assess whether veterinary diagnostic laboratories can detect Delta and Omicron variants spiked in canine nasal matrix or viral transport medium. METHODS: The ILC organizer was an independent laboratory that prepared inactivated Delta variant at levels of 25 to 1000 copies per 50 µL of nasal matrix for blinded analysis. Omicron variant at 1000 copies per 50 µL of transport medium was also included. Feline infectious peritonitis virus (FIPV) RNA was used as a confounder for specificity assessment. Fourteen test samples were prepared for each participant. Participants used their routine diagnostic procedures for RNA extraction and real-time reverse transcriptase-PCR. Results were analyzed according to International Organization for Standardization (ISO) 16140-2:2016. RESULTS: Overall, laboratories demonstrated 93% detection for Delta and 97% for Omicron at 1000 copies per 50 µL. Specificity was 97% for blank samples and 100% for blank samples with FIPV. No differences in Cycle Threshold (Ct) values were significant for samples with the same virus levels between N1 and N2 markers, nor between the 2 variants. CONCLUSIONS: The results indicated that all ILC3 participants were able to detect both Delta and Omicron variants. The canine nasal matrix did not significantly affect SARS-CoV-2 detection.


Assuntos
COVID-19 , SARS-CoV-2 , Gatos , Humanos , Animais , Cães , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/veterinária , Laboratórios , Pandemias , RNA , Teste para COVID-19
3.
Food Chem X ; 17: 100538, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36845497

RESUMO

Through their suggestive name, non-targeted methods (NTMs) do not aim at a predefined "needle in the haystack." Instead, they exploit all the constituents of the haystack. This new type of analytical method is increasingly finding applications in food and feed testing. However, the concepts, terms, and considerations related to this burgeoning field of analytical testing need to be propagated for the benefit of those associated with academic research, commercial development, or official control. This paper addresses frequently asked questions regarding terminology in connection with NTMs. The widespread development and adoption of these methods also necessitate the need to develop innovative approaches for NTM validation, i.e., evaluating the performance characteristics of a method to determine if it is fit-for-purpose. This work aims to provide a roadmap for approaching NTM validation. In doing so, the paper deliberates on the different considerations that influence the approach to validation and provides suggestions therefor.

4.
J Vet Diagn Invest ; 34(5): 825-834, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35983593

RESUMO

The COVID-19 pandemic presents a continued public health challenge. Veterinary diagnostic laboratories in the United States use RT-rtPCR for animal testing, and many laboratories are certified for testing human samples; hence, ensuring that laboratories have sensitive and specific SARS-CoV2 testing methods is a critical component of the pandemic response. In 2020, the FDA Veterinary Laboratory Investigation and Response Network (Vet-LIRN) led an interlaboratory comparison (ILC1) to help laboratories evaluate their existing RT-rtPCR methods for detecting SARS-CoV2. All participating laboratories were able to detect the viral RNA spiked in buffer and PrimeStore molecular transport medium (MTM). With ILC2, Vet-LIRN extended ILC1 by evaluating analytical sensitivity and specificity of the methods used by participating laboratories to detect 3 SARS-CoV2 variants (B.1; B.1.1.7 [Alpha]; B.1.351 [Beta]) at various copy levels. We analyzed 57 sets of results from 45 laboratories qualitatively and quantitatively according to the principles of ISO 16140-2:2016. More than 95% of analysts detected the SARS-CoV2 RNA in MTM at ≥500 copies for all 3 variants. In addition, for nucleocapsid markers N1 and N2, 81% and 92% of the analysts detected ≤20 copies in the assays, respectively. The analytical specificity of the evaluated methods was >99%. Participating laboratories were able to assess their current method performance, identify possible limitations, and recognize method strengths as part of a continuous learning environment to support the critical need for the reliable diagnosis of COVID-19 in potentially infected animals and humans.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , COVID-19/diagnóstico , COVID-19/veterinária , Teste para COVID-19 , Humanos , Imunidade Inata , Laboratórios , Linfócitos , Pandemias/veterinária , RNA Viral/análise , SARS-CoV-2/genética , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
5.
Foods ; 11(8)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35454695

RESUMO

Meat species authentication in food is most commonly based on the detection of genetic variations. Official food control laboratories frequently apply single and multiplex real-time polymerase chain reaction (PCR) assays and/or DNA arrays. However, in the near future, DNA metabarcoding, the generation of PCR products for DNA barcodes, followed by massively parallel sequencing by next generation sequencing (NGS) technologies, could be an attractive alternative. DNA metabarcoding is superior to well-established methodologies since it allows simultaneous identification of a wide variety of species not only in individual foodstuffs but even in complex mixtures. We have recently published a DNA metabarcoding assay for the identification and differentiation of 15 mammalian species and six poultry species. With the aim to harmonize analytical methods for food authentication across EU Member States, the DNA metabarcoding assay has been tested in an interlaboratory ring trial including 15 laboratories. Each laboratory analyzed 16 anonymously labelled samples (eight samples, two subsamples each), comprising six DNA extract mixtures, one DNA extract from a model sausage, and one DNA extract from maize (negative control). Evaluation of data on repeatability, reproducibility, robustness, and measurement uncertainty indicated that the DNA metabarcoding method is applicable for meat species authentication in routine analysis.

6.
Pharmaceuticals (Basel) ; 15(2)2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-35215332

RESUMO

Adverse effects of drug combinations and their underlying mechanisms are highly relevant for safety evaluation, but often not fully studied. Hydroxychloroquine (HCQ) and azithromycin (AZM) were used as a combination therapy in the treatment of COVID-19 patients at the beginning of the pandemic, leading to higher complication rates in comparison to respective monotherapies. Here, we used human-induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) to systematically investigate the effects of HCQ, AZM, and their combination on the structure and functionality of cardiomyocytes, and to better understand the underlying mechanisms. Our results demonstrate synergistic adverse effects of AZM and HCQ on electrophysiological and contractile function of iPSC-CMs. HCQ-induced prolongation of field potential duration (FPDc) was gradually increased during 7-day treatment period and was strongly enhanced by combination with AZM, although AZM alone slightly shortened FPDc in iPSC-CMs. Combined treatment with AZM and HCQ leads to higher cardiotoxicity, more severe structural disarrangement, more pronounced contractile dysfunctions, and more elevated conduction velocity, compared to respective monotreatments. Mechanistic insights underlying the synergistic effects of AZM and HCQ on iPSC-CM functionality are provided based on increased cellular accumulation of HCQ and AZM as well as increased Cx43- and Nav1.5-protein levels.

7.
Foods ; 12(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36613357

RESUMO

Food fraud, even when not in the news, is ubiquitous and demands the development of innovative strategies to combat it. A new non-targeted method (NTM) for distinguishing spelt and wheat is described, which aids in food fraud detection and authenticity testing. A highly resolved fingerprint in the form of spectra is obtained for several cultivars of spelt and wheat using liquid chromatography coupled high-resolution mass spectrometry (LC-HRMS). Convolutional neural network (CNN) models are built using a nested cross validation (NCV) approach by appropriately training them using a calibration set comprising duplicate measurements of eleven cultivars of wheat and spelt, each. The results reveal that the CNNs automatically learn patterns and representations to best discriminate tested samples into spelt or wheat. This is further investigated using an external validation set comprising artificially mixed spectra, samples for processed goods (spelt bread and flour), eleven untypical spelt, and six old wheat cultivars. These cultivars were not part of model building. We introduce a metric called the D score to quantitatively evaluate and compare the classification decisions. Our results demonstrate that NTMs based on NCV and CNNs trained using appropriately chosen spectral data can be reliable enough to be used on a wider range of cultivars and their mixes.

8.
J Vet Diagn Invest ; 33(6): 1039-1051, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34293974

RESUMO

The continued search for intermediate hosts and potential reservoirs for SARS-CoV2 makes it clear that animal surveillance is critical in outbreak response and prevention. Real-time RT-PCR assays for SARS-CoV2 detection can easily be adapted to different host species. U.S. veterinary diagnostic laboratories have used the CDC assays or other national reference laboratory methods to test animal samples. However, these methods have only been evaluated using internal validation protocols. To help the laboratories evaluate their SARS-CoV2 test methods, an interlaboratory comparison (ILC) was performed in collaboration with multiple organizations. Forty-four sets of 19 blind-coded RNA samples in Tris-EDTA (TE) buffer or PrimeStore transport medium were shipped to 42 laboratories. Results were analyzed according to the principles of the International Organization for Standardization (ISO) 16140-2:2016 standard. Qualitative assessment of PrimeStore samples revealed that, in approximately two-thirds of the laboratories, the limit of detection with a probability of 0.95 (LOD95) for detecting the RNA was ≤20 copies per PCR reaction, close to the theoretical LOD of 3 copies per reaction. This level of sensitivity is not expected in clinical samples because of additional factors, such as sample collection, transport, and extraction of RNA from the clinical matrix. Quantitative assessment of Ct values indicated that reproducibility standard deviations for testing the RNA with assays reported as N1 were slightly lower than those for N2, and they were higher for the RNA in PrimeStore medium than those in TE buffer. Analyst experience and the use of either a singleplex or multiplex PCR also affected the quantitative ILC test results.


Assuntos
COVID-19 , RNA Viral , Animais , COVID-19/veterinária , Laboratórios , RNA Viral/genética , Reprodutibilidade dos Testes , SARS-CoV-2 , Sensibilidade e Especificidade
9.
Cytometry A ; 97(12): 1265-1275, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32790129

RESUMO

Caspase-3 is a well-described protease with many roles that impact the fate of a cell. During apoptosis, caspase-3 acts as an executioner caspase with important proteolytic functions that lead to the final stages of programmed cell death. Owing to this key role, caspase-3 is exploited intracellularly as a target of control of apoptosis for therapeutic outcomes. Yet the activation of caspase-3 during apoptosis is challenged by other roles and functions (e.g., paracrine signaling). This brief report presents a way to track caspase-3 levels using a flow cytometer that measures excited state fluorescence lifetimes and a signal processing approach that leads to a graphical phasor-based interpretation. An established Förster resonance energy transfer (FRET) bioprobe was used for this test; the connected donor and acceptor fluorophore is cleavable by caspase-3 during apoptosis induction. With the cell-by-cell decay kinetic data and phasor analyses we generate a caspase activation trajectory, which is used to interpret activation throughout apoptosis. When lifetime-based cytometry is combined with a FRET bioprobe and phasor analyses, enzyme activation can be simplified and quantified with phase and modulation data. We envision extrapolating this approach to high content screening, and reinforce the power of phasor approaches with cytometric data. Analyses such as these can be used to cluster cells by their phase and modulation "lifetime fingerprint" when the intracellular fluorescent probe is utilized as a sensor of enzyme activity. © 2020 The Authors. Cytometry Part A published by Wiley Periodicals LLC on behalf of International Society for Advancement of Cytometry.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Corantes Fluorescentes , Apoptose , Caspase 3 , Humanos , Microscopia de Fluorescência
10.
Cytometry A ; 95(1): 70-79, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30369063

RESUMO

Autofluorescence from the intracellular metabolite, NAD(P)H, is a biomarker that is widely used and known to reliably screen and report metabolic activity as well as metabolic fluctuations within cells. As a ubiquitous endogenous fluorophore, NAD(P)H has a unique rate of fluorescence decay that is altered when bound to coenzymes. In this work we measure the shift in the fluorescence decay, or average fluorescence lifetime (1-3 ns), of NAD(P)H and correlate this shift to changes in metabolism that cells undergo during apoptosis. Our measurements are made with a flow cytometer designed specifically for fluorescence lifetime acquisition within the ultraviolet to violet spectrum. Our methods involved culture, treatment, and preparation of cells for cytometry and microscopy measurements. The evaluation we performed included observations and quantification of the changes in endogenous emission owing to the induction of apoptosis as well as changes in the decay kinetics of the emission measured by flow cytometry. Shifts in NAD(P)H fluorescence lifetime were observed as early as 15 min post-treatment with an apoptosis inducing agent. Results also include a phasor analysis to evaluate free to bound ratios of NAD(P)H at different time points. We defined the free to bound ratios as the ratio of 'short-to-long' (S/L) fluorescence lifetime, where S/L was found to consistently decrease with an increase in apoptosis. With a quantitative framework such as phasor analysis, the short and long lifetime components of NAD(P)H can be used to map the cycling of free and bound NAD(P)H during the early-to-late stages of apoptosis. The combination of lifetime screening and phasor analyses provides the first step in high throughput metabolic profiling of single cells and can be leveraged for screening and sorting for a range of applications in biomedicine. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.


Assuntos
Apoptose , Citometria de Fluxo/métodos , NADP/metabolismo , Fluorescência , Células HeLa , Humanos , Cinética , Microscopia de Fluorescência
11.
J Biomed Opt ; 23(7): 1-10, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29992797

RESUMO

Förster resonance energy transfer (FRET) continues to be a useful tool to study movement and interaction between proteins within living cells. When FRET as an optical technique is measured with flow cytometry, conformational changes of proteins can be rapidly measured cell-by-cell for the benefit of screening and profiling. We exploit FRET to study the extent of activation of α4ß1 integrin dimers expressed on the surface of leukocytes. The stalk-like transmembrane heterodimers when not active lay bent and upon activation extend outward. Integrin extension is determined by changes in the distance of closest approach between an FRET donor and acceptor, bound at the integrin head and cell membrane, respectively. Time-resolved flow cytometry analysis revealed donor emission increases up to 17%, fluorescence lifetime shifts over 1.0 ns during activation, and FRET efficiencies of 37% and 26% corresponding to the inactive and active integrin state, respectively. Last, a graphical phasor analysis, including population clustering, gating, and formation of an FRET trajectory, added precision to a comparative analysis of populations undergoing FRET, partial donor recovery, and complete donor recovery. This work establishes a quantitative cytometric approach for profiling fluorescence donor decay kinetics during integrin conformational changes on a single-cell level.


Assuntos
Citometria de Fluxo/métodos , Transferência Ressonante de Energia de Fluorescência/métodos , Integrinas/análise , Integrinas/química , Linhagem Celular Tumoral , Humanos , Integrinas/metabolismo , Conformação Proteica , Processamento de Sinais Assistido por Computador
12.
Methods Mol Biol ; 1678: 421-446, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29071689

RESUMO

The focus of this chapter is time-resolved flow cytometry, which is broadly defined as the ability to measure the timing of fluorescence decay from excited fluorophores that pass through cytometers or high-throughput cell counting and cell sorting instruments. We focus on this subject for two main reasons: first, to discuss the nuances of hardware and software modifications needed for these measurements because currently, there are no widespread time-resolved cytometers nor a one-size-fits-all approach; and second, to summarize the application space for fluorescence lifetime-based cell counting/sorting owing to the recent increase in the number of investigators interested in this approach. Overall, this chapter is structured into three sections: (1) theory of fluorescence decay kinetics, (2) modern time-resolved flow cytometry systems, and (3) cell counting and sorting applications. These commentaries are followed by conclusions and discussion about new directions and opportunities for fluorescence lifetime measurements in flow cytometry.


Assuntos
Citometria de Fluxo , Corantes Fluorescentes , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Fluorescência , Transferência Ressonante de Energia de Fluorescência , Cinética , Proteínas Luminescentes , Fatores de Tempo , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...