Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 43(3): 318-24, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11884490

RESUMO

UNLABELLED: The object of this study was to develop a new technique for the quantitative measurement of lymphatic function. The rate of clearance of radiolabeled protein from a subcutaneous depot is supplemented by measurement of the appearance of the protein in venous blood. This initial study was performed on normal arms, with a view to subsequent clinical application such as in the investigation of women with breast cancer--related lymphedema (BCRL). METHODS: Fourteen healthy volunteers (12 women, 2 men) and 8 women awaiting surgery for breast cancer were recruited for the study. Each received subcutaneous depot injection of protein solution in the second dorsal web space of each hand, labeled with (111)In on one side and with (99m)Tc on the other side. Human serum albumin (HSA) was the protein used in the first 8 subjects and human polyclonal immunoglobulin G (HIgG) was used thereafter. The activity at each depot was measured at regular intervals using a collimated sodium iodide scintillation detector, and the activity in venous blood sampled from both arms was measured in an automatic sample counter. RESULTS: (99m)Tc-HSA cleared from the depot consistently faster than (111)In-HSA (P = 0.001). The proportions of radionuclide remaining bound to protein in venous blood were higher for (99m)Tc than for (111)In. HIgG displayed improved labeling stability for both nuclides, reflected in equal rates of clearance. Blood activity rose steadily after an early latent phase and for HIgG correlated strongly with the rate of clearance from the depot (P < 0.001). Marked variation between individuals was observed. CONCLUSION: A dual-isotope technique relies on identical behavior of the 2 radiopharmaceuticals used. This study shows that this is the case with respect to HIgG but not HSA. (99m)Tc-HSA cleared faster than (111)In-HSA and yet displayed better in vivo labeling stability. We conclude that (111)In dissociates from HSA in the depot but then becomes locally bound. Using HIgG, a close correlation was observed between the rates of clearance from the depot and the appearance in venous blood. This finding suggests that HIgG would be a suitable marker for subsequent dual-isotope studies on women with BCRL.


Assuntos
Radioisótopos de Índio , Linfedema/diagnóstico por imagem , Linfocintigrafia , Compostos Organometálicos , Compostos Radiofarmacêuticos , Albumina Sérica , Agregado de Albumina Marcado com Tecnécio Tc 99m , Adulto , Idoso , Braço , Neoplasias da Mama/complicações , Preparações de Ação Retardada , Feminino , Humanos , Imunoglobulina G/administração & dosagem , Injeções Subcutâneas , Linfa/fisiologia , Linfedema/etiologia , Linfedema/fisiopatologia , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Compostos de Organotecnécio/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Albumina Sérica/administração & dosagem , Albumina Sérica Humana , Agregado de Albumina Marcado com Tecnécio Tc 99m/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...