Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endourol ; 25(7): 1187-91, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21631303

RESUMO

BACKGROUND AND PURPOSE: Laparoendoscopic single-site (LESS) surgery produces virtually no scar but is technically challenging because of the loss of triangulation. The objective of this study is to compare classic transumbilical LESS nephrectomy with needlescopic-assisted laparoscopy (NAL) surgery. In doing so, we evaluated whether the addition of a single 2-mm subcostal port could restore triangulation while not jeopardizing recovery or cosmetic outcome in the porcine model. MATERIALS AND METHODS: Ten female farm pigs were randomized to laparoscopic nephrectomy with either LESS or NAL. In LESS, a TriPort was placed through a single 2.5-cm umbilical incision. In NAL, 5- and 10-mm ports were placed in the umbilicus and a 2-mm port was placed in the midclavicular line. Preoperative, perioperative, and postoperative parameters were compared. Variables were analyzed with the Wilcoxon signed-rank test and two-tailed Fisher exact test. Cosmesis was evaluated objectively using the Vancouver Scar Scale and subjectively by a blinded dermatologist. A cost analysis was performed. RESULTS: Estimated blood loss was minimal in both groups (28.8 mL in LESS and 9.4 mL in NAL). Operative time was significantly shorter in NAL (103 vs 150 min; P<0.001). There was no difference in complications (2 vs 1; P=0.500), objective cosmesis (3.9 vs 3.8; P>0.2), or subjective cosmesis (2 vs 3; P=0.500). The NAL protocol had significantly lower disposable equipment costs ($363 vs $1696). CONCLUSIONS: The addition of a 2-mm subcostal port and the restoration of triangulation in the NAL protocol enable shorter operative times, increased surgeon comfort, improved technical ease, and lower costs while maintaining the scarless cosmesis of the traditional LESS protocol.


Assuntos
Laparoscopia/instrumentação , Laparoscopia/métodos , Modelos Animais , Nefrectomia/instrumentação , Nefrectomia/métodos , Sus scrofa/cirurgia , Animais , Equipamentos Descartáveis/economia , Feminino , Laparoscopia/economia , Nefrectomia/economia , Estudos Prospectivos , Distribuição Aleatória , Fatores de Tempo , Resultado do Tratamento
2.
Urology ; 77(1): 92-6, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20573378

RESUMO

OBJECTIVES: To compare the incidence of ocular complications (OC) and corneal abrasion (CA) after hand-assisted laparoscopic donor nephrectomy (HALDN) and open donor nephrectomy (ODN). METHODS: A retrospective review was conducted of 241 consecutive patients (141 HALDN and 100 ODN) over a 9-year period. OC were strictly defined as ocular complaints requiring any treatment or ophthalmologic consultation. Chi-square tests were used to compare the incidence of OC and CA by type of surgery. RESULTS: OC were observed in 9 HALDN patients (6.4%) and no ODN patients (0%; P = .01). All OC in HALDN patients involved the dependent eye (P <.001). CA occurred in 2 HALDN patients (1.4%) compared with no ODN patients (0%; P = .23). HALDN patients had significantly higher net fluid intake than the ODN patients (P <.01). CONCLUSIONS: The increased OC and CA seen in HALDN patients may result from the increased fluid intake, flank positioning, and potential increased venous compression resulting from the effects of the pneumoperitoneum. The fact that the dependent eye was involved in all patients suggests conjunctival edema as a potential common pathway. The high frequency of OC suggests the importance of techniques to minimize OC after HALDN.


Assuntos
Oftalmopatias/epidemiologia , Oftalmopatias/etiologia , Laparoscopia/efeitos adversos , Nefrectomia/efeitos adversos , Nefrectomia/métodos , Doadores de Tecidos , Adulto , Doenças da Córnea/epidemiologia , Doenças da Córnea/etiologia , Humanos , Incidência , Estudos Retrospectivos
3.
J Urol ; 182(6): 2762-7, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19837431

RESUMO

PURPOSE: Unenhanced multidetector computerized tomography is the imaging modality of choice for urinary calculi but exposes patients to substantial radiation doses with a subsequent risk of radiation induced secondary malignancy. We compared ultra low dose and conventional computerized tomography protocols for detecting distal ureteral calculi in a cadaveric model. MATERIALS AND METHODS: A total of 85 calcium oxalate stones 3 to 7 mm long were prospectively placed in 14 human cadaveric distal ureters in 56 random configurations. The intact kidneys, ureters and bladders were placed in a human cadaveric vehicle and computerized tomography was performed at 140, 100, 60, 30, 15 and 7.5 mA seconds while keeping other imaging parameters constant. Images were independently reviewed in random order by 2 blinded radiologists to determine the sensitivity and specificity of each mA second setting. RESULTS: Overall sensitivity and specificity were 98% and 83%, respectively. Imaging using 140, 100, 60, 30, 15 and 7.5 mA second settings resulted in 98%, 97%, 97%, 96%, 98% and 97% sensitivity, and 83%, 83%, 83%, 86%, 80% and 84% specificity, respectively. Interobserver agreement was excellent (kappa >0.87). There was no significant difference in sensitivity or specificity at any mA second settings. All false-negative results were noted for 3 mm calculi at a similar frequency at each mA second setting. CONCLUSIONS: Ultra low dose computerized tomography protocols detected distal ureteral calculi in a fashion similar to that of conventional computerized tomography protocols in a cadaveric model. These protocols may decrease the radiation dose up to 95%, reducing the risk of secondary malignancies.


Assuntos
Oxalato de Cálcio , Protocolos Clínicos , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Cálculos Ureterais/diagnóstico por imagem , Cadáver , Oxalato de Cálcio/análise , Feminino , Humanos , Sensibilidade e Especificidade , Cálculos Ureterais/química
4.
J Endourol ; 22(5): 973-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18393647

RESUMO

PURPOSE: A variety of techniques have been used to secure the renal artery and vein during laparoscopic donor nephrectomy. The purpose of this study is to compare the amount of vessel length lost when the artery and vein are secured with four different techniques. METHODS: A model was constructed to simulate a left laparoscopic donor nephrectomy. In this model vessel length lost was determined when veins were secured using polymer locking (PL) clips, the endo-GIA stapling device, and the endo-TA stapling device. Arterial length lost was determined for the same three techniques, as well as securing the artery with titanium (Ti) clips. RESULTS: The mean arterial length lost for the PL clips, Ti clips, endo-TA, and endo-GIA stapling devices was 6.2, 6.3, 9.8, and 10.0 mm, respectively. Both clip types produced less loss of arterial length than both types of stapling devices (P<0.001), and there was no difference between the two types of stapling devices (P=0.73) or clips (P=0.85). The mean venous length lost for the PL clip, endo-GIA, and endo-TA stapling devices was 5.7, 10.1, and 9.4 mm, respectively. The PL clips resulted in significantly less vessel loss compared to both stapling devices (P<0.001), and there was no difference between the two stapling devices (P=0.40). CONCLUSIONS: Both types of clips resulted in longer graft arterial lengths compared to both stapling devices. PL clips resulted in longer graft vein length compared to the two stapling devices. The endo-TA stapling device was limited in this model by its inability to articulate.


Assuntos
Hemostasia Cirúrgica/instrumentação , Laparoscopia , Modelos Biológicos , Nefrectomia , Artéria Renal/cirurgia , Veias Renais/cirurgia , Animais , Humanos , Transplante de Rim , Ligadura/métodos , Artéria Renal/patologia , Veias Renais/patologia , Instrumentos Cirúrgicos , Grampeadores Cirúrgicos , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS