Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Geod ; 95(6): 65, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720449

RESUMO

We measured the components of the 31-m-long vector between the two very-long-baseline interferometry (VLBI) antennas at the Kokee Park Geophysical Observatory (KPGO), Hawaii, with approximately 1 mm precision using phase delay observables from dedicated VLBI observations in 2016 and 2018. The two KPGO antennas are the 20 m legacy VLBI antenna and the 12 m VLBI Global Observing System (VGOS) antenna. Independent estimates of the vector between the two antennas were obtained by the National Geodetic Survey (NGS) using standard optical surveys in 2015 and 2018. The uncertainties of the latter survey were 0.3 and 0.7 mm in the horizontal and vertical components of the baseline, respectively. We applied corrections to the measured positions for the varying thermal deformation of the antennas on the different days of the VLBI and survey measurements, which can amount to 1 mm, bringing all results to a common reference temperature. The difference between the VLBI and survey results are 0.2 ± 0.4 mm, -1.3 ± 0.4 mm, and 0.8 ± 0.8 mm in the East, North, and Up topocentric components, respectively. We also estimate that the Up component of the baseline may suffer from systematic errors due to gravitational deformation and uncalibrated instrumental delay variations at the 20 m antenna that may reach ± 10 and -2 mm, respectively, resulting in an accuracy uncertainty on the order of 10 mm for the relative heights of the antennas. Furthermore, possible tilting of the 12 m antenna increases the uncertainties in the differences in the horizontal components to 1.0 mm. These results bring into focus the importance of (1) correcting to a common reference temperature the measurements of the reference points of all geodetic instruments within a site, (2) obtaining measurements of the gravitational deformation of all antennas, and (3) monitoring local motions of the geodetic instruments. These results have significant implications for the accuracy of global reference frames that require accurate local ties between geodetic instruments, such as the International Terrestrial Reference Frame (ITRF).

2.
Science ; 186(4167): 920-2, 1974 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-17730913

RESUMO

Nine separate very-long-baseline interferometry (VLBI) experiments, carried out in 1972 and 1973 with radio telescopes 3900 kilometers apart, yielded values for the baseline length with a root-mean-square deviation about the mean of less than 20 centitneters. The corresponding fractional spread is about five parts in 10(8). Changes in universal time and in polar motion were also detertnined accurately from these data; the root-mean-square scatter of these results with respect to those based on optical methods were 2.9 milliseconds and 1.3 meters, respectively. Solid-earth tides were apparently detected, but no useful estimate of their amplituide was extracted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...