Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Analyst ; 127(8): 1045-9, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12195944

RESUMO

A method was developed for the simultaneous determination of the following nine volatile sulfur compounds in gas samples: carbon disulfide, carbonyl sulfide, ethyl sulfide, ethyl methyl sulfide, hydrogen sulfide, isopropanethiol, methanethiol, methyl disulfide and methyl sulfide. The target compounds were preconcentrated by solid-phase microextraction (SPME) and determined by gas chromatography combined with mass spectrometry. Experimental design was employed to optimize the extraction time and temperature and concurrent detection of the nine compounds was achieved by using an SPME fiber coated with Carboxen-polydimethylsiloxane (75 microns). Detection limits ranged from 1 ppt (v/v) for carbon disulfide to 350 ppt (v/v) for hydrogen sulfide and calibration functions were linear up to 20 ppb (v/v) for all the compounds investigated.


Assuntos
Compostos de Enxofre/análise , Poluentes Químicos da Água/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos
2.
J Chromatogr A ; 963(1-2): 57-64, 2002 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-12188001

RESUMO

Procedures were assessed for quantifying nine volatile sulfur compounds found in complex gaseous samples collected at a biogas-production plant and a sewage treatment plant. The target compounds were extracted by solid-phase microextraction (using the 75-microm Carboxen-polydimethylsiloxane fiber coating) at 22 degrees C for 20 min, and analyzed by GC-MS. Detection limits ranged between 1 pptv (v/v) for carbon disulfide and 470 pptv (v/v) for hydrogen sulfide. High amounts of organic compounds were found during full-scan analysis of the samples and standard additions to individual sub-samples revealed that the analysis was subject to matrix effects. However, the functions obtained by standard additions were still linear and quantification was possible for all the compounds tested except hydrogen sulfide. No detectable losses were observed during storage in the sampling containers, made of Tedlar film, over a storage period of 20 h. However, water permeated through the walls and the relative humidity in the bag increased during storage until it reached the ambient level. Finally, it was shown that the drying agent, CaCl2, caused no detectable losses of any of the compounds.


Assuntos
Gases/química , Compostos de Enxofre/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Sensibilidade e Especificidade , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...