Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36616776

RESUMO

In general, optical methods for geometrical measurements are influenced by the surface properties of the examined object. In Structure from Motion (SfM), local variations in surface color or topography are necessary for detecting feature points for point-cloud triangulation. Thus, the level of contrast or texture is important for an accurate reconstruction. However, quantitative studies of the influence of surface texture on geometrical reconstruction are largely missing. This study tries to remedy that by investigating the influence of object texture levels on reconstruction accuracy using a set of reference artifacts. The artifacts are designed with well-defined surface geometries, and quantitative metrics are introduced to evaluate the lateral resolution, vertical geometric variation, and spatial-frequency information of the reconstructions. The influence of texture level is compared to variations in capturing range. For the SfM measurements, the ContextCapture software solution and a 50 Mpx DSLR camera are used. The findings are compared to results using calibrated optical microscopes. The results show that the proposed pipeline can be used for investigating the influence of texture on SfM reconstructions. The introduced metrics allow for a quantitative comparison of the reconstructions at varying texture levels and ranges. Both range and texture level are seen to affect the reconstructed geometries although in different ways. While an increase in range at a fixed focal length reduces the spatial resolution, an insufficient texture level causes an increased noise level and may introduce errors in the reconstruction. The artifacts are designed to be easily replicable, and by providing a step-by-step procedure of our testing and comparison methodology, we hope that other researchers will make use of the proposed testing pipeline.


Assuntos
Imageamento Tridimensional , Software , Imageamento Tridimensional/métodos , Movimento (Física) , Artefatos , Microscopia
2.
Sci Rep ; 7(1): 14746, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-29116170

RESUMO

Botulinum-toxin A (BoNT/A) is used for a wide range of conditions. Intramuscular administration of BoNT/A inhibits the release of acetylcholine at the neuromuscular junction from presynaptic motor neurons causing muscle-paralysis. The aim of the present study was to investigate the effect of high dose intramuscular BoNT/A injections (6 UI = 60 pg) on muscle tissue. The gait pattern of the rats was significantly affected 3 weeks after BoNT/A injection. The ankle joint rotated externally, the rats became flat footed, and the stride length decreased after BoNT/A injection. Additionally, there was clear evidence of microstructural changes on the tissue level by as evidenced by 3D imaging of the muscles by Synchrotron Radiation X-ray Tomographic Microscopy (SRXTM). Both the fibrillar and the non-fibrillar tissues were affected. The volume fraction of fibrillary tissue was reduced significantly and the non-fibrillar tissue increased. This was accompanied by a loss of the linear structure of the muscle tissue. Furthermore, gene expression analysis showed a significant upregulation of COL1A1, MMP-2, TGF-b1, IL-6, MHCIIA and MHCIIx in the BoNT/A injected leg, while MHVIIB was significantly downregulated. IN CONCLUSION: The present study reveals that high dose intramuscular BoNT/A injections cause microstructural damage of the muscle tissue, which contributes to impaired gait.


Assuntos
Toxinas Botulínicas Tipo A/administração & dosagem , Perfilação da Expressão Gênica , Regulação da Expressão Gênica/efeitos dos fármacos , Músculo Esquelético/efeitos dos fármacos , Animais , Peso Corporal/efeitos dos fármacos , Toxinas Botulínicas Tipo A/toxicidade , Relação Dose-Resposta a Droga , Marcha/efeitos dos fármacos , Masculino , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Músculo Esquelético/fisiopatologia , Miofibrilas/efeitos dos fármacos , Miofibrilas/metabolismo , Miofibrilas/patologia , Ratos , Ratos Sprague-Dawley
3.
Meat Sci ; 100: 217-21, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25460128

RESUMO

The objective of this study was to evaluate the use of X-ray phase-contrast tomography combined with 3D image segmentation to investigate the heat induced structural changes in meat. The measurements were performed at the Swiss synchrotron radiation light source using a grating interferometric setup. The non-destructive method allowed the same sample to be measured before and after cooking. Heat denaturation resulted in a 36% decrease in the volume of the muscle fibers, while solubilization of the connective tissues increased the volume from 8.4%to 24.9%. The cooking loss was quantified and separated into a water phase and a gel phase formed by the sarcoplasmic proteins in the exudate. The results show that X-ray phase contrast tomography offers unique possibilities in studies both the meat structure and the different meat component such as water, fat, connective tissue and myofibrils in a qualitative and quantitative manner without prior sample preparation as isolation of single muscle components, calibration or histology.


Assuntos
Tecido Conjuntivo , Culinária , Temperatura Alta , Carne/análise , Proteínas Musculares/análise , Miofibrilas , Tomografia Computadorizada por Raios X/métodos , Animais , Humanos , Imageamento Tridimensional/métodos , Transição de Fase , Água , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...