Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Pacing Clin Electrophysiol ; 23(10 Pt 1): 1532-8, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11060875

RESUMO

Ambulatory ECG monitoring in patients with recurrent syncope is nondiagnostic in the majority of cases. Recently, an ECG implantable loop recorder (ILR) has been introduced. The ILR performs continuous ECG monitoring over a period of at least 14 months. From February 1997 to September 1999, 35 patients underwent implantation of an ILR. During a mean follow-up of 11 +/- 8 months, 24 (69%) patients had recurrent syncope or presyncope events. Four (11%) patients were not capable of activating the ILR to save the event. A symptom-rhythm correlation could be studied in 20 (83%) of 24 patients. Forty of 44 recurrences were captured by the ILR. There were 14 (40%) patients with at least one syncopal episode. An arrhythmic cause for syncope was found in eight of them (bradycardia in four and tachycardia in four). In the other six patients the heart rhythm was normal. In 17 (49%) patients with 1-year follow-up, the mean syncope event rate 12 months before ILR implantation was 4.7 +/- 2.4, whereas the mean syncope event rate 12 months after ILR implantation was 1.3 +/- 0.7 (P < 0.01). Resolution of symptoms was observed in 6 (17%) patients. These patients were significantly younger than patients without resolution (50 +/- 18 vs 69 +/- 14 years, p < 0.01) and five were women. Three (9%) patients died during follow-up, all of them were noncompliant during their follow-up. In conclusion, the ILR made symptom-rhythm correlation possible in 83% of patients with recurrent syncope. Syncope recurrences decreased significantly after implantation of the device, especially in the younger patients. Noncompliant patients had a high mortality rate.


Assuntos
Eletrocardiografia/instrumentação , Marca-Passo Artificial , Síncope/diagnóstico , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Estudos de Viabilidade , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Recidiva , Síncope/etiologia , Fatores de Tempo
2.
Heart ; 83(1): 35-9, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10618333

RESUMO

AIM: To evaluate the angiographic, myocardial perfusion, and wall motion abnormalities in patients with severe compared with mild worsening of regional function during dobutamine stress echocardiography (DSE) for evaluation of myocardial ischaemia. METHODS: 147 patients with significant coronary artery disease and new or worsening wall motion abnormalities during DSE were enrolled. Left ventricular function was evaluated using a 16 segment/4 grade score model where 1 = normal and 4 = dyskinesis. Simultaneous sestamibi SPECT myocardial perfusion imaging was performed in all patients. RESULTS: Severe worsening of regional function (an increase in wall motion score of two grades or more in >/= 1 segment) was detected in 37 patients, while 110 patients had mild worsening (an increase in wall motion score of no more than one grade in >/= 1 segment). Patients with severe worsening of regional function had more stenotic coronary arteries (2.31 (0.8) v 1.97 (0. 8) (mean (SD)) (p <0.05), a higher prevalence of left anterior descending coronary artery disease (95% v 73%) (p < 0.05), a higher resting wall motion score index (1.71 (0.42) v 1.51 (0.40) (p = 0. 01), and more stress perfusion defects (3.8 (1.5) v 2.8 (1.5) (p < 0.001) compared with patients with mild worsening. Multivariate analysis identified the number of stress perfusion defects (p < 0. 005, chi(2) = 8.8) and the number of ischaemic segments on echocardiography (p < 0.05, chi(2) = 4.3) as independent variables associated with severe worsening of regional function. CONCLUSIONS: The grade of worsening of regional function during DSE predicts the underlying extent of myocardial perfusion abnormalities. The occurrence of severe worsening of regional function is associated with variables known to predict worse prognosis in patients with coronary artery disease.


Assuntos
Cardiotônicos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Dobutamina , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Angiografia Coronária , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Ultrassonografia
3.
Heart ; 81(4): 398-403, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10092567

RESUMO

OBJECTIVE: To investigate the functional significance of chronotropic incompetence during dobutamine stress echocardiography. PATIENTS AND METHODS: The functional significance of chronotropic incompetence was evaluated during dobutamine stress echocardiography in 512 patients without beta blocker treatment who underwent dobutamine stress echocardiography (up to 40 microg/kg/min) and completed the protocol or reached the target heart rate. Mean (SD) age was 60 (12) years (313 men, 199 women). Chronotropic incompetence was defined as failure to achieve 85% of the maximum exercise heart rate predicted for age and sex (220 - age in men; 200 - age in women) at maximum dobutamine dose. RESULTS: Chronotropic incompetence occurred in 196 patients (38%). Affected patients were significantly younger, more likely to be men (both p << 0.001) and smokers (p < 0.05), had a higher prevalence of previous myocardial infarction (p < 0.005) and resting wall motion abnormalities (p < 0. 05), and had a lower resting heart rate (p << 0.001) and systolic blood pressure (p << 0.001) than patients without chronotropic incompetence, but there was no difference in the overall prevalence of ischaemia and significant coronary artery disease. By multivariate analysis, independent predictors of chronotropic incompetence were a lower resting heart rate (p << 0.001), younger age (p << 0.001), and male sex (p << 0.001). CONCLUSIONS: The relations among sex, age, and chronotropic incompetence show the need to titrate the dobutamine dose using specific data based on age and sex related heart rate responses to dobutamine rather than to an exercise stress test. Obtaining specific heart rate criteria is necessary to determine whether chronotropic incompetence represents a real failure to achieve a normal response or is the result of applying an inappropriate gold standard.


Assuntos
Cardiotônicos , Doença das Coronárias/diagnóstico , Dobutamina , Frequência Cardíaca/efeitos dos fármacos , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão
4.
J Am Soc Echocardiogr ; 12(1): 48-54, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9882778

RESUMO

There is a controversy regarding the functional significance of stress-induced ST-segment elevation (STE) in Q leads. However, the effect of revascularization on the induction of STE was not investigated. We studied 35 patients with old Q-wave myocardial infarction who underwent coronary artery bypass grafting (CABG) of the infarct-related artery with dobutamine (up to 40 microg/kg per minute) stress echocardiography before and 3 months after CABG. Ischemia was defined as new or worsened wall motion abnormalities. Functional recovery was defined as a reduction of regional wall motion score of 1 or more in 2 or more segments from the pre-CABG to post-CABG resting echocardiogram with the use of the 16-segment/5-grade score model. STE (>/=0.1 mV J-point elevation lasting 80 ms in >/=2 Q leads) occurred in 20 (57%) patients. There was no significant difference between patients with and those without STE before CABG with regard to the prevalence of peri-infarction ischemia (85% vs 80%) or index of improvement of regional function after CABG (0.26 +/- 0.26 vs 0.29 +/- 0.33). STE was reinduced to the same level in 4 patients after CABG, whereas 16 patients showed absent reinduction (8 patients) or reduced level (8 patients) of STE. Functional changes associated with absent reinduction or less STE after CABG were absence of reinduction of regional ischemia in 13 patients, improvement of resting regional function in 5 patients, and resection of scarred segments in 4 patients. Among the 4 patients with persistent dobutamine-induced STE, 1 patient had persistent ischemia and 2 showed worsening of resting regional function. Although dobutamine-induced STE in patients with old Q-wave infarction referred for CABG cannot identify patients with a higher prevalence of ischemia, the lack of reinduction of this pattern after CABG correlates with absent reinduction of ischemia in most of patients.


Assuntos
Cardiotônicos , Ponte de Artéria Coronária , Dobutamina , Ecocardiografia , Eletrocardiografia/efeitos dos fármacos , Infarto do Miocárdio/cirurgia , Distribuição de Qui-Quadrado , Angiografia Coronária , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Prevalência , Recuperação de Função Fisiológica , Recidiva , Grau de Desobstrução Vascular
5.
Am J Cardiol ; 82(11): 1339-44, 1998 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-9856916

RESUMO

The diagnosis of coronary artery disease (CAD) on the basis of inducible ischemia in > or = 2, rather than 1, segments was suggested to improve specificity of dobutamine stress echocardiography (DSE). However, the impact of using these criteria on the sensitivity and accuracy of DSE was not studied. We studied the accuracy of DSE (up to 40 microg/kg/min) for the diagnosis of CAD in 290 patients with suspected myocardial ischemia using the criteria of > or = 1 and > or = 2 ischemic segments. Ischemia was defined as new or worsening wall motion abnormalities using a 16-segment model. Among the 85 patients without previous myocardial infarction, significant CAD was detected in 51 (60%). Sensitivity, specificity, and accuracy of DSE using > or = 1 ischemic segment were 73%, 85%, and 78%, respectively. Those using > or = 2 segments were 67%, 94%, and 78%, respectively (p = NS). Regional specificity improved by using > or = 2 segments (91% vs 96%, p <0.05) at the expense of an equivalent reduction in regional sensitivity (60% vs 44%, p <0.05), whereas the regional accuracy was similar (80% vs 79% for > or = 1 and > or = 2 segments, respectively). In the 205 patients with previous myocardial infarction, the criterion of ischemia in > or = 1 segment had a higher sensitivity and accuracy for overall diagnosis of CAD (75% vs 64%, p <0.05; 77% vs 68%, p <0.05), infarct-related CAD (64% vs 47%, p <0.005; 70% vs 57%, p <0.01), and remote CAD (74% vs 57%, p <0.005; 78% vs 69%, p <0.05) than the criterion of > or = 2 segments, respectively. It is concluded that in patients without previous myocardial infarction, the use of > or = 2 ischemic segments by DSE for the diagnosis of CAD does not improve the accuracy of DSE compared with the criterion of > or = 1 ischemic segment. Conversely, in patients with previous infarction the use of > or = 2 segments reduces the overall and regional sensitivity and accuracy without a significant improvement in specificity.


Assuntos
Cardiotônicos , Doença das Coronárias/diagnóstico , Dobutamina , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia/métodos , Eletrocardiografia , Teste de Esforço , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
6.
Diabetes Care ; 21(11): 1797-802, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9802723

RESUMO

OBJECTIVE: Dobutamine stress testing is increasingly used for the diagnosis and functional evaluation of coronary artery disease. However, little is known about the safety and feasibility of this stress modality in diabetic patients. RESEARCH DESIGN AND METHODS: We studied the impact of diabetes on hemodynamic profile and on the safety and feasibility of dobutamine (up to 40 microg x kg(-1) x min(-1)) and atropine (up to 1 mg) stress echocardiography for the diagnosis of coronary artery disease in 1,446 consecutive patients (aged 60+/-12 years, 962 men) with limited exercise capacity and suspected myocardial ischemia. Of these, 184 patients were known to have IDDM or NIDDM. The test was considered feasible when 85% of the maximal heart rate and/or an ischemic end point (new or worsened wall motion abnormalities, ST segment depression, or angina) was achieved. RESULTS: No myocardial infarction or death occurred during the test. There was no significant difference between diabetic and nondiabetic patients with regard to heart rate increase during dobutamine stress echocardiography (58+/-25 vs. 61+/-24 beats/min), peak rate pressure product (18,400+/-3,135 vs. 18,048+/-4454), or the prevalence of hypotension (systolic blood pressure drop of >40 mmHg) (7 vs. 5%), ventricular tachycardia (5.4 vs. 4.5%), and supraventricular tachycardia (3 vs. 4%) during the test. Dobutamine stress echocardiography was feasible in 92% of the diabetic patients and in 90% of the nondiabetic patients. Coronary angiography was performed in 55 diabetic and 240 nondiabetic patients. Sensitivity, specificity, and accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery disease in diabetic patients were 81, 85, and 82%. Those in nondiabetic patients were 74, 87, and 77%, respectively (NS). CONCLUSIONS: Dobutamine stress echocardiography is a feasible method for the diagnosis of coronary artery disease in patients with limited exercise capacity with a comparable safety, feasibility, and accuracy in diabetic and nondiabetic patients.


Assuntos
Atropina , Cardiotônicos , Doença das Coronárias/diagnóstico , Angiopatias Diabéticas/diagnóstico , Dobutamina , Idoso , Arritmias Cardíacas/induzido quimicamente , Pressão Sanguínea/efeitos dos fármacos , Angiografia Coronária , Angiopatias Diabéticas/complicações , Ecocardiografia/métodos , Teste de Esforço , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações
7.
J Nucl Med ; 39(10): 1662-6, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9776264

RESUMO

UNLABELLED: Dobutamine stress testing is increasingly used for the diagnosis and functional evaluation of coronary artery disease. However, the relationship between myocardial perfusion abnormalities and complications of the test has not been studied. METHODS: We studied the hemodynamic profile, safety and feasibility of dobutamine (up to 40 microg/kg/min)-atropine (up to 1 mg) stress myocardial perfusion SPECT imaging (with 201TI, 99mTc-MIBI or tetrofosmin) in a consecutive series of 1076 patients (age = 59 +/- 11 yr, 50% with previous myocardial infarction) referred for evaluation of myocardial ischemia. RESULTS: No infarction or death occurred during the test. The test was considered feasible (achievement of 85% of the target heart rate or an ischemic endpoint) in 1005 patients (94%). Hypotension (systolic blood pressure drop > or = 40 mm Hg) occurred in 37 patients (3.4%). Independent predictors were higher baseline systolic blood pressure (p < 0.0001), number of ischemic segments (p < 0.05) and age (p < 0.05). Supraventricular tachyarrhythmias occurred in 48 patients (4.4%). Independent predictors were fixed perfusion defect (infarction) score (p < 0.005) and age (p < 0.05). Ventricular tachycardia occurred in 41 patients (3.8%). Independent predictors were infarction score (p < 0.01) and male gender (p < 0.05). All arrhythmias terminated spontaneously or after metoprolol administration. CONCLUSION: Dobutamine-atropine myocardial perfusion scintigraphy is a feasible method for the evaluation of coronary artery disease with a safety profile and feasibility comparable to those reported for dobutamine stress echocardiography. Patients with more severe fixed perfusion abnormalities are at a higher risk of developing tachyarrhythmias during the test.


Assuntos
Atropina , Doença das Coronárias/diagnóstico por imagem , Dobutamina , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Estudos de Viabilidade , Feminino , Humanos , Hipotensão/etiologia , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Fatores de Risco , Segurança , Taquicardia/etiologia , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio
8.
Chest ; 114(4): 1097-104, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9792583

RESUMO

OBJECTIVES: To compare the accuracy of dobutamine stress echocardiography (DSE) and simultaneous 99mTc sestamibi (MIBI) single-photon emission CT (SPECT) imaging for the diagnosis of coronary artery stenosis in women. PATIENTS: Seventy women with limited exercise capacity referred for evaluation of myocardial ischemia. METHODS: DSE (up to 40 microg/kg/min) was performed in conjunction with stress MIBI SPECT. Resting MIBI images were acquired 24 h after the stress test. Ischemia was defined as new or worsened wall motion abnormalities confirmed by DSE and as reversible perfusion defects confirmed by MIBI. Significant coronary artery disease was defined as > or = 50% luminal diameter stenosis. RESULTS: DSE was positive for ischemia in 35 of 45 patients with coronary artery stenosis and in 2 of 25 patients without coronary artery stenosis (sensitivity = 78% CI, 68 to 88; specificity = 92% CI, 85 to 99; and accuracy = 83% CI, 74 to 92). A positive MIBI study for ischemia occurred in 29 patients with coronary artery stenosis and in 7 patients without coronary artery stenosis (sensitivity = 64% CI, 53 to 76; specificity = 72% CI, 61 to 83; and accuracy = 67% CI, 56 to 78 [p < 0.05 vs DSE]). In the 59 vascular regions with coronary artery stenosis, the regional sensitivity of DSE was higher than MIBI (69% CI, 62 to 77 vs 51% CI, 42 to 59, p < 0.05), whereas specificity in the 81 vascular regions without significant stenosis was similar (89% CI, 84 to 94 vs 88% CI, 82 to 93, respectively). CONCLUSION: DSE is a useful noninvasive method for the diagnosis of coronary artery stenosis in women and provides a higher overall and regional diagnostic accuracy than dobutamine MIBI SPECT in this particular population.


Assuntos
Doença das Coronárias/diagnóstico , Dobutamina , Ecocardiografia/métodos , Tolerância ao Exercício/fisiologia , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Teste de Esforço , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Contração Miocárdica , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Nucl Cardiol ; 5(5): 491-7, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9796896

RESUMO

OBJECTIVE: To assess the accuracy of dobutamine stress myocardial perfusion single photon emission computed tomographic imaging (SPECT) for the diagnosis of vascular stenosis after coronary artery bypass grafting (CABG). BACKGROUND: Exercise thallium scintigraphy is a clinically useful method for the diagnosis of graft stenosis after CABG. Although dobutamine perfusion scintigraphy is an alternative method for the evaluation of patients with limited exercise capacity, its value in the diagnosis of vascular stenosis after CABG has not been studied. METHODS: Dobutamine (up to 40 lg/kg/min)-atropine (up to 1 mg) stress test in conjunction with myocardial perfusion SPECT imaging (201T1 or 99m technetium sestamibi [MIBII) was performed in 71 patients (mean age 58 9 years, 57 men) with limited exercise capacity referred for evaluation of myocardial ischemia 3.7 3.5 years after CABG. Significant vascular stenosis was defined as >50% luminal diameter stenosis of a graft or a native nongrafted coronary artery and was predicted on the basis of reversible perfusion abnormalities. RESULTS: Significant vascular stenosis was detected in 52 patients. Sensitivity, specificity, and accuracy of reversible perfusion defects at dobutamine SPECT for the overall diagnosis of vascular stenosis were 81%, confidence interval (CI) 72 to 90, 79%, CI 69 to 88, and 80%, CI 71 to 90, respectively. Significant vascular stenosis was detected in 73 arterial regions. Sensitivity, specificity, and accuracy of dobutamine SPECT for the diagnosis of regional vascular stenosis were 66%, CI 58 to 74, 83%, CI 76 to 89, and 74%, CI 67 to 81, respectively. Patients with multivessel stenosis had a higher number of ischemic segments (1.6 + 1.3 vs 1 + 1, P < .05) and ischemic perfusion score (3.2 2.7 vs 2.2 + 2.3, P < .05) than patients with single-vessel stenosis, respectively. Significant graft stenosis was detected in 67 graft regions. Sensitivity, specificity, and accuracy of dobutamine SPECT for the diagnosis of regional graft stenosis were 64%, CI 56 to 73, 85%, CI 78 to 91, and 74%, CI 66 to 82, respectively. CONCLUSION: Dobutamine stress myocardial perfusion SPECT imaging is a useful method for the diagnosis of significant vascular stenosis after CABG in patients with limited exercise capacity.


Assuntos
Atropina , Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Dobutamina , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Angiografia Coronária , Eletrocardiografia , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade
10.
J Am Soc Echocardiogr ; 11(5): 436-41, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9619615

RESUMO

Dobutamine-induced hypotension has been disregarded as a marker of more severe functional abnormalities in patients with suspected coronary artery disease. However, its functional significance in patients with myocardial infarction has not been studied. The aim of this study was to define the predictors of systolic blood pressure (SBP) response to dobutamine in patients with previous myocardial infarction. Dobutamine stress (up to 40 microg/kg per minute) echocardiography was performed in 326 patients with prior myocardial infarction referred for evaluation of myocardial ischemia. A 16-segment, four-grade score model was used to assess left ventricular function. Wall motion score index was derived by summation of wall motion score divided by 16. SBP and heart rate increased from rest to peak dobutamine stress (127 +/- 22 vs 134 +/- 27 mm Hg and 72 +/- 14 vs 122 +/- 24 bpm, p < 0.00001 in both). An increase of SBP > or = 30 mm Hg occurred in 50 patients (15%). By multivariate analysis, independent predictors of failure of SBP increase were higher peak wall motion score index (p < 0.001), higher resting SBP (p < 0.01), and medication with calcium channel blockers (p < 0.05). SBP drop > or = 20 mm Hg occurred in 54 patients (17%). Independent predictors of SBP drop were higher resting wall motion score index (p < 0.001), higher resting SBP (p < 0.0001), and older age (p < 0.05). In patients with myocardial infarction, left ventricular function and baseline systolic blood pressure are powerful predictors of SBP response to dobutamine stress testing.


Assuntos
Agonistas Adrenérgicos beta , Pressão Sanguínea/efeitos dos fármacos , Dobutamina , Ecocardiografia/métodos , Infarto do Miocárdio/fisiopatologia , Angiografia Coronária , Feminino , Humanos , Hipotensão/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia
11.
Eur J Nucl Med ; 25(1): 69-78, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9396877

RESUMO

Stress echocardiography has been considered an accurate method for the diagnosis of coronary artery disease in hypertensive patients and in patients with left ventricular hypertrophy. In contrast, the specificity of myocardial perfusion scintigraphy in these patients has been questioned. The aim of this study was to compare the accuracy of these two imaging modalities in conjunction with dobutamine stress test for the diagnosis of coronary artery disease in hypertensive patients with and without left ventricular hypertrophy. Dobutamine (up to 40 microg kg-1min-1) stress echocardiography in conjunction with sestamibi (MIBI) single-photon emission tomography (SPET) was performed in 84 patients with the diagnosis of systemic hypertension who had been referred for evaluation of myocardial ischaemia. Ischaemia was defined as new or worsened wall motion abnormalities at echocardiography and reversible perfusion defects at SPET. Significant coronary artery disease (>/=50% luminal diameter stenosis) was detected in 66 patients (79%). The sensitivity, specificity and accuracy of the ischaemic pattern at echocardiography for the diagnosis of coronary artery disease were 73% (CI 63%-82%), 83% (CI 75%-91%) and 75% (CI 66%-84%), those for MIBI were 67% (CI 57%-77%), 83% (CI 75%-91%) and 70% (CI 60%-80%) respectively (P = NS vs echocardiography). Significant stenosis was detected in 123 (49%) of the 252 analysed coronary arteries. The sensitivity, specificity and accuracy of echocardiography for the regional diagnosis of coronary artery disease were 63% (CI 56%-69%), 90% (CI 86%-94%) and 77% (CI 72%-82%). Those for MIBI were 58% (CI 51%-64%), 91% (CI 87%-94%) and 75% (CI 69%-80) respectively (P = NS vs echocardiography). Left ventricular hypertrophy was detected in 59 patients (70%) by echocardiography and did not influence the overall or regional specificity of echocardiography or MIBI SPET. It is concluded that in hypertensive patients, dobutamine stress echocardiography and MIBI SPET have a comparable accuracy for the overall and regional diagnosis of coronary artery disease. Hypertensive patients with or without left ventricular hypertrophy should not be considered unsuitable candidates for stress myocardial perfusion scintigraphy.


Assuntos
Agonistas Adrenérgicos beta , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/diagnóstico , Dobutamina , Hipertensão/complicações , Hipertrofia Ventricular Esquerda/complicações , Adulto , Angina Pectoris/diagnóstico , Pressão Sanguínea/fisiologia , Doença das Coronárias/etiologia , Ecocardiografia , Eletrocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único
12.
Am J Cardiol ; 80(11): 1414-8, 1997 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-9399713

RESUMO

The accuracy of dobutamine stress echocardiography (DSE) for the diagnosis of coronary artery disease (CAD) has not been yet evaluated in women. We studied the effect of gender on the accuracy of DSE for the diagnosis of CAD in 306 consecutive patients (210 men and 96 women) with limited exercise capacity and suspected myocardial ischemia who underwent coronary angiography within 3 months of DSE. There were no serious complications during DSE. Men had a higher prevalence of nonsustained ventricular tachycardia (7% vs 0.03%, p <0.05) and supraventricular tachycardia (9% vs 0.03%, p <0.05) during the test compared with women. Peak stress rate-pressure product was not different in men and women (18,140 +/- 4,187 vs 18,543 +/- 4,223). Significant CAD (> or =50% luminal diameter stenosis) was present in 171 men (81%) and in 62 women (65%, p <0.005). The sensitivity, specificity, and accuracy of ischemic pattern at DSE for the diagnosis of significant CAD were 76% (confidence interval [CI] 67 to 84), 94% (CI 89 to 99), and 82% (CI 75 to 90) in women and 73% (CI 67 to 79), 77% (CI 71 to 83), and 74% (CI 68 to 80) in men, respectively. Overall specificity was higher in women than in men (p <0.05). Regional accuracy of DSE was significantly higher in women than in men in the 3 arterial regions (84% [CI 79 to 88] vs 75% [CI 72 to 79], p <0.005). It is concluded that DSE is a safe and feasible method for the diagnosis of CAD in women. The overall specificity and the regional accuracy of DSE are higher in women than in men. Further studies are required to evaluate the functional significance of these findings and their reproducibility in different patient populations.


Assuntos
Cardiotônicos , Doença das Coronárias/diagnóstico , Dobutamina , Ecocardiografia , Caracteres Sexuais , Cardiotônicos/efeitos adversos , Angiografia Coronária , Doença das Coronárias/epidemiologia , Doença das Coronárias/fisiopatologia , Dobutamina/efeitos adversos , Ecocardiografia/efeitos adversos , Ecocardiografia/métodos , Eletrocardiografia , Feminino , Humanos , Hipotensão/induzido quimicamente , Hipotensão/epidemiologia , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Segurança , Sensibilidade e Especificidade , Taquicardia/induzido quimicamente , Taquicardia/epidemiologia
13.
Am J Cardiol ; 79(7): 883-8, 1997 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-9104899

RESUMO

The aim of this study was to assess the influence of the severity of coronary artery stenosis and the grade of collateral circulation on myocardial viability in patients with chronic left ventricular (LV) dysfunction undergoing coronary artery bypass grafting. Forty patients (age 59 +/- 8 years) with old myocardial infarction were studied by dobutamine stress echocardiography (DSE) before coronary artery bypass grafting. LV function was assessed using a 16-segment, 5-grade score model. Viability and functional recovery were respectively defined as a reduction in wall motion score > or = 1 at low-dose DSE and at follow-up echocardiograms obtained 3 months after surgery. There were 56 stenotic coronary arteries subtending severely dyssynergic myocardial segments, of which 38 were occluded. Among 186 severely dyssynergic segments, functional recovery occurred in 42 (23%). There was no significant difference between myocordial regions with patent or occluded coronary arteries with respect to prevalence of viability or functional recovery and percentage of viable or recovered segments relative to the total number of dyssynergic segments. In patients with total occlusion, these parameters were not different between regions with different collateral grades. Sensitivity, specificity, and accuracy of low-dose DSE for prediction of regional functional recovery were 71%, 90%, and 86%, respectively. It is concluded that in patients with chronic LV dysfunction, the presence of total occlusion of coronary arteries supplying severely dyssynergic regions does not imply a lower prevalence or extent of functional recovery after revascularization, regardless of the grade of angiographically visualized collaterals. Low-dose DSE can identify myocardial regions with a high probability of functional improvement after revascularization regardless of the severity of underlying coronary stenosis or collateralization of the involved coronary vessel.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia , Infarto do Miocárdio/cirurgia , Disfunção Ventricular Esquerda/cirurgia , Circulação Colateral/fisiologia , Angiografia Coronária , Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico , Doença das Coronárias/fisiopatologia , Dobutamina , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
14.
J Am Soc Echocardiogr ; 10(2): 189-91, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9083976

RESUMO

A congenital coronary artery fistula is a rare anomaly characterized by a communication between one or more coronary arteries and a cardiac chamber, coronary vein, or less frequently, the pulmonary artery. The reported complications of this anomaly are congestive heart failure, infective endocarditis, and myocardial infarction. Although angina is not an infrequent complaint in the adult population with coronary to pulmonary artery fistulas, objective evidence of myocardial ischemia in the absence of concomitant atherosclerotic coronary artery disease has not been described. In this report, we describe an adult patient with chest pain and bicoronary to pulmonary artery fistulas in whom myocardial ischemia was documented by high-dose dobutamine stress echocardiography.


Assuntos
Fístula Artério-Arterial/complicações , Anomalias dos Vasos Coronários/complicações , Ecocardiografia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/etiologia , Artéria Pulmonar/anormalidades , Fístula Artério-Arterial/congênito , Cardiotônicos , Dobutamina , Teste de Esforço , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único
15.
Heart ; 77(2): 115-21, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9068392

RESUMO

OBJECTIVE: To assess the relation between ST segment elevation during the dobutamine stress test and late improvement of function after acute Q wave myocardial infarction. PATIENTS AND DESIGN: 70 patients were studied a mean (SD) 8 (3) days after acute myocardial infarction with high dose dobutamine-atropine stress echocardiography and a follow up echocardiogram at 85 (10) days. A score model based on 16 segments and four grades was used to assess left ventricular function. Functional improvement was defined as a reduction of wall motion score > or = 1 in > or = 1 segments at follow up. INTERVENTION: Myocardial revascularisation was performed in 23 patients (33%) before follow up studies. RESULTS: ST segment elevation occurred in 40 patients (57%). Late functional improvement occurred in 35 patients (50%). Functional improvement was more common in patients with ST segment elevation (68% v 30%, P < 0.005) and they had a higher mean (SD) number of improved segments at follow up (1.9 (2.2) v 0.5 (1.1), P < 0.005). The wall motion score index decreased between baseline and follow up in patients with ST segment elevation (1.54 (0.50) v 1.48 (0.43), P < 0.05) but not in patients without ST segment elevation (1.39 (0.60) v 1.45 (0.47)). The accuracy of ST segment elevation for the prediction of functional improvement was similar to that of low dose dobutamine echocardiography in patients with anterior infarction (80% v 83%) and in patients who underwent revascularisation (78% v 83% respectively). CONCLUSION: In patients with a recent Q wave myocardial infarction, dobutamine-induced ST segment elevation is a valuable marker of myocardial viability particularly when the test is performed without or with suboptimal echocardiographic imaging.


Assuntos
Cardiotônicos , Dobutamina , Contração Miocárdica , Infarto do Miocárdio/diagnóstico por imagem , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Função Ventricular Esquerda
16.
Nucl Med Commun ; 18(2): 122-8, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9076767

RESUMO

After successful percutaneous transluminal coronary angioplasty (PTCA), restenosis occurs in a relatively high proportion of patients. Exercise thallium scintigraphy is a useful method for the detection of restenosis. In patients unable to exercise, dobutamine perfusion scintigraphy may represent a feasible alternative. However, its diagnostic accuracy in this clinical setting has not been evaluated. We studied 40 patients (29 males, 11 females) aged 57 +/- 9 years, at a mean of 185 +/- 80 days after successful PTCA with a high-dose dobutamine (up to 40 micrograms kg-1 min-1) stress test, in conjunction with 99Tcm-methoxyisobutyl isonitrile (99Tcm-MIBI) single photon emission tomography (SPET). Significant restenosis was defined as > or = 50% luminal diameter stenosis of a coronary segment with previous PTCA and was predicted on the basis of the occurrence of reversible perfusion defects in the corresponding territories. Reversible perfusion defects occurred in 20 of 29 arteries with and in 4 of 17 arteries without restenosis. The sensitivity of dobutamine MIBI for the detection of restenosis in arteries with previous PTCA was 69% (CI = 56-82), the specificity 76% (CI = 64-89), the positive predictive value 83% (CI = 73-94), the negative predictive value 59% (CI = 45-73) and accuracy 72% (CI = 59-85). The overall sensitivity of 99Tcm-MIBI SPET for the diagnosis of significant coronary stenosis (including arteries without previous PTCA) on a patient basis was 79% (CI = 67-92), the specificity 82% (CI = 70-94) and accuracy 80% (CI = 68-92). The sensitivity of 99Tcm-MIBI SPET was significantly higher than that of electrocardiography (79 vs 38%, P < 0.005). It is concluded that dobutamine 99Tcm-MIBI SPET is a useful method for the detection of restenosis after PTCA in patients unable to perform an exercise stress test.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/diagnóstico por imagem , Dobutamina , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão , Adulto , Angina Pectoris , Pressão Sanguínea , Angiografia Coronária , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Recidiva , Sensibilidade e Especificidade
17.
Am J Cardiol ; 79(1): 7-12, 1997 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-9024727

RESUMO

This study compares the value of dobutamine stress echocardiography and 99m-technetium methoxyisobutyl-isonitrile (MIBI) single-photon emission computed tomography (SPECT) in the assessment of extent and location of coronary narrowing in patients with healed myocardial infarction. Dobutamine (up to 40 microg/kg/ min)-atropine (up to 1 mg) stress echocardiography (DSE) in conjunction with MIBI SPECT was performed in 72 patients (52 men, mean age 57 +/- 11 years) with healed myocardial infarction referred for evaluation of myocardial ischemia. Ischemia was defined as new or worsened wall motion abnormalities at DSE and reversible perfusion defects at MIBI SPECT. Significant stenosis (> or = 50% luminal diameter stenosis) of the infarct-related artery was detected in 45 patients and of other coronary arteries in 22 patients. Sensitivity and specificity of remote ischemia for diagnosis of remote coronary stenosis were 68% (95% confidence interval [CI] 57 to 80) and 93% (CI 86 to 99) for DSE, and 64% (CI 52 to 76), and 90% (CI 83 to 98) for MIBI SPECT, respectively. The positive predictive value and specificity of peri-infarction ischemia for the diagnosis of infarct-related artery stenosis were 89% (CI 81 to 97) and 82% (CI 73 to 92) for DSE, and 87% (CI 79 to 95) and 82% (CI 73 to 92) for SPECT, respectively. The agreement between both techniques was higher for the diagnosis of remote than peri-infarction ischemia (84% vs 66%, p = 0.02). It is concluded that in patients with myocardial infarction undergoing dobutamine stress testing, both echocardiography and MIBI SPECT are clinically useful methods for the diagnosis of remote and infarct-related coronary artery stenosis.


Assuntos
Cardiotônicos , Doença das Coronárias/diagnóstico , Dobutamina , Ecocardiografia , Infarto do Miocárdio/complicações , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Constrição Patológica , Doença das Coronárias/complicações , Doença das Coronárias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/fisiopatologia , Sensibilidade e Especificidade
18.
Eur J Nucl Med ; 23(10): 1354-60, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8781140

RESUMO

The aim of the study was to compare the extent and severity of reversible underperfusion in silent versus painful myocardial ischaemia during the dobutamine stress test. A consecutive series of 85 patients with significant coronary artery disease and reversible perfusion defects on technetium-99m methoxyisobutylisonitrile single-photon emission tomography performed at rest and during high-dose dobutamine stress (up to 40 microg kg-1 min-1) were studied. The left ventricle was divided into six segments. An ischaemic perfusion score was derived quantitatively by subtracting the rest from the stress defect score. Patients with multivessel disease had a higher ischaemic score (610+/-762 vs 310+/-411, P<0. 05) and a higher number of reversible perfusion defects (2.1+/-1.2 vs 1.1+/-0.8, P<0.01) than patients with single-vessel disease. Typical angina occurred in 37 patients (44%) during the test. There was no significant difference between patients with and patients without angina with respect to age, gender, peak rate-pressure product, prevalence of previous myocardial infarction, diabetes mellitus, multivessel disease or number of stenotic coronary arteries. Stress, rest and ischaemic scores as well as the number and distribution of reversible defects were not different in patients with and patients without angina. Patients with angina more frequently had a history of typical angina before the test (43% vs 17%, P<0.01) and ST-segment depression during the test (54% vs 25%, P<0.01). It is concluded that in patients with coronary artery disease and ischaemia detected by dobutamine scintigraphy, the extent and severity of coronary artery disease and myocardial perfusion abnormalities are similar with or without angina during stress testing.


Assuntos
Angina Pectoris/diagnóstico por imagem , Dobutamina , Coração/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Angina Pectoris/fisiopatologia , Estudos de Casos e Controles , Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia
19.
Am J Cardiol ; 77(11): 955-9, 1996 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-8644645

RESUMO

There are no standard criteria for the diagnosis of myocardial ischemia in akinetic segments during dobutamine stress echocardiography (DSE). The aim of the study was to assess the relation between different responses of akinetic segments during DSE and ischemia assessed by thallium-201 single-photon emission computed tomography (SPECT). Dobutamine-atropine stress echocardiography with simultaneous stress-reinjection thallium-201 SPECT was performed in 67 patients with old myocardial infarction significant and coronary artery stenosis. Fourteen myocardial segments were matched for both DSE and SPECT. Ischemia on SPECT was defined as reversible thallium defects. In 257 akinetic segments, 4 patterns during DSE were identified: (1) biphasic response in 41 segments (16%), defined as improvement at low dose (5 to 10 microgram/kg/min) followed by worsening at high dose; (2) persistent akinesia in 155 segments (60%); (3) akinesia becoming dyskinesia in 39 segments (15%); and (4) sustained improvement in 22 segments (9%). Reversible thallium defects were detected in 21 segments (51%) in group 1, in 20 segments (13%) in group 2, none in group 3, and in 2 segments in group 4 (9%). The prevalence of reversible defects in biphasic segments was higher compared with other patterns (p <0.00001 vs groups 2 and 3, p <0.005 vs group 4). The ischemic perfusion defect score was significantly higher in group 1 than group 2. The positive predictive value of biphasic response for reversible thallium defects was similar to that of stress-induced dyssynergia in normal segments at rest (51% vs 58%). It is concluded that of the various responses of akinetic segments to dobutamine infusion, the biphasic response is associated with the highest prevalence and greatest severity of ischemic on thallium SPECT. Observation of contractile response at both low- and high-dose DSE is a valuable approach for the diagnosis of myocardial ischemia in akinetic segments.


Assuntos
Dobutamina , Ecocardiografia , Contração Miocárdica , Isquemia Miocárdica/fisiopatologia , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Valor Preditivo dos Testes , Radioisótopos de Tálio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA