Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 13(2): 92-98, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30665879

RESUMO

BACKGROUND: To investigate whether aortic valve calcification (AVC) scoring performed with different workstation platforms generates comparable and thus software-independent results. METHODS: In this IRB-approved retrospective study, we included 100 consecutive patients with symptomatic aortic stenosis undergoing CT prior to transcatheter aortic valve implantation. Two independent observers performed AVC scoring on non-enhanced images with commercially available software platforms of four vendors (GE, Philips, Siemens, 3mensio). Gender-specific Agatston score cut-off values were applied according to current recommendations to assign patients to different likelihood categories of aortic stenosis (unlikely to very likely). Comparative analysis of Agatston scores between the four platforms were performed by using Kruskal-Wallis analysis, Spearman rank correlation, linear regression analysis, and Bland-Altman analysis. Differences in category assignment were compared using Fisher's exact test and Cohen's kappa. RESULTS: For both observers, each workstation platform produced slightly different numeric AVC Agatston scores, however, without statistical significance (p = 0.96 and p = 0.98). Excellent correlation was found between platforms, with r = 0.991-0.996 (Spearman) and r2 = 0.981-0.992 (regression analysis) for both observers. Bland-Altman analyses revealed small mean differences with narrow limits of agreement between platforms (mean differences: 6 ±â€¯128 to 100 ±â€¯179), for inter-observer (mean differences: 1 ±â€¯43 to 12 ±â€¯70), and intra-observer variability (mean differences: 9 ±â€¯42 to 20 ±â€¯96). Observer 1 assigned 11 (kappa: 0.85-0.97) and observer 2 assigned 10 patients (kappa: 0.88-0.95) to different likelihood groups of severe aortic stenosis with at least one platform. Overall, there was no significant difference of likelihood assignment between platforms (p = 0.98 and p = 1.0, respectively). CONCLUSION: While absolute values differ slightly, common commercially available software platforms produce comparable results for AVC scoring, which indicates software-independence of the method.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
2.
J Am Coll Cardiol ; 66(19): 2075-2088, 2015.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063629

RESUMO

BACKGROUND:Cardiac biomarker release signifying myocardial injury post-transcatheter aortic valve replacement (TAVR) is common, yet its clinical impact within a large TAVR cohort receiving differing types of valve and procedural approaches is unknown.OBJECTIVES:This study sought to determine the incidence, clinical impact, and factors associated with cardiac biomarker elevation post TAVR.METHODS:This multicenter study included 1,131 consecutive patients undergoing TAVR with balloon-expandable (58%) or self-expandable (42%) valves. Transfemoral and transapical (TA) approaches were selected in 73.1% and 20.3% of patients, respectively. Creatine kinase-myocardial band (CK-MB) measurements were obtained at baseline and at several time points within the initial 72 h post TAVR. Echocardiography was performed at baseline and at 6- to 12-month follow-up.RESULTS:Overall, 66% of the TAVR population demonstrated some degree of myocardial injury as determined by a rise in CK-MB levels (peak value: 1.6-fold [interquartile range (IQR): 0.9 to 2.8-fold]). A TA approach and major procedural complications were independently associated with higher peak of CK-MB levels (p < 0.01 for all), which translated into impaired systolic left ventricular function at 6 to 12 months post TAVR (p < 0.01). A greater rise in CK-MB levels independently associated with an increased 30-day, late (median of 21 [IQR: 8 to 36] months) overall and cardiovascular mortality (p < 0.001 for all)...


Assuntos
Biomarcadores , Creatina Quinase , Estenose das Carótidas , Substituição da Valva Aórtica Transcateter
3.
Neth Heart J ; 22(3): 115-21, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24338787

RESUMO

AIMS: Heart failure (HF) management is complicated by difficulties in clinical assessment. Biomarkers may help guide HF management, but the correspondence between clinical evaluation and biomarker serum levels has hardly been studied. We investigated the correlation between biomarkers and clinical signs and symptoms, the influence of patient characteristics and comorbidities on New York Heart Association (NYHA) classification and the effect of using biomarkers on clinical evaluation. METHODS AND RESULTS: This post-hoc analysis comprised 622 patients (77 ± 8 years, 76 % NYHA class ≥3, 80 % LVEF ≤45 %) participating in TIME-CHF, randomising patients to either NT-proBNP-guided or symptom-guided therapy. Biomarker measurements and clinical evaluation were performed at baseline and after 1, 3, 6, 12 and 18 months. NT-proBNP, GDF-15, hs-TnT and to a lesser extent hs-CRP and cystatin-C were weakly correlated to NYHA, oedema, jugular vein distension and orthopnoea (ρ-range: 0.12-0.33; p < 0.01). NT-proBNP correlated more strongly to NYHA class in the NT-proBNP-guided group compared with the symptom-guided group. NYHA class was significantly influenced by age, body mass index, anaemia, and the presence of two or more comorbidities. CONCLUSION: In HF, biomarkers correlate only weakly with clinical signs and symptoms. NYHA classification is influenced by several comorbidities and patient characteristics. Clinical judgement seems to be influenced by a clinician's awareness of NT-proBNP concentrations.

4.
Anaesthesist ; 60(12): 1095-108, 2011 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-22179072

RESUMO

Surgical replacement of aortic valves is the gold standard for therapy of high grade aortic valve stenosis. However, the changes in demography confront the responsible medical discipline with an increasingly higher risk profile of patients which necessitates the development of new less invasive alternative forms of treatment for the surgical therapy of aortic valve stenosis. This developmental process has progressed from mini-thoracotomy to transcatheter aortic valve implantation (TAVI). The TAVI procedure is a new therapeutic option for treatment of patients with high grade aortic valve stenosis and high perioperative morbidity and mortality risks with conventional aortic valve replacement. Because TAVI can be carried out while the heart is still beating and without a sternotomy or heart-lung maschine, this procedure is particularly suitable for elderly multimorbid patients and/or patients with previous cardiac surgery. The initial results of large prospective multicenter studies underline the value of TAVI in the modern treatment of high risk patients with symptomatic aortic valve stenosis. In addition to an understanding of the surgical procedure, anesthetists must have precise knowledge of the perioperative anesthesia management and possible complications of the procedure.


Assuntos
Anestesia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Cateterismo/métodos , Implante de Prótese de Valva Cardíaca/métodos , Anticoagulantes/uso terapêutico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Humanos , Monitorização Intraoperatória , Estudos Multicêntricos como Assunto , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Toracotomia
5.
Circulation ; 122(13): 1319-27, 2010 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-20837893

RESUMO

BACKGROUND: Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. METHODS AND RESULTS: Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. CONCLUSIONS: Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Taxa de Sobrevida , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Clin Pharmacol Ther ; 87(6): 686-92, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20445533

RESUMO

Inhibition of the renin-angiotensin system (RAS) improves hemodynamics and may ameliorate oxidative stress in heart failure (HF). Through activation of nicotinamide adenine dinucleotide phosphate oxidase, angiotensin II induces superoxide, which is primarily cleared by cytosolic copper-zinc superoxide dismutase (Cu/Zn-SOD). We examined the interdependency of hemodynamics and levels of Cu/Zn-SOD and oxidized low-density lipoprotein (oxLDL) in HF patients, using a randomized, double-blinded, crossover design to compare (i) the outcomes of single-agent therapy with either benazepril or valsartan alone vs. the combination thereof and (ii) the outcome of single-agent treatment with benazepril vs. single-agent treatment with valsartan. After each treatment, arterial (ART) and coronary sinus (CS) blood samples were collected. Cu/Zn-SOD and oxLDL levels were higher in CS samples than in ART samples. Furthermore, patients under combined treatment exhibited the highest CS levels of Cu/Zn-SOD, whereas there was no significant difference between the groups on either benazepril or valsartan alone. This finding suggests an augmentation of the cardiac antioxidative potential under more complete RAS inhibition. Cu/Zn-SOD and oxLDL levels correlated with measures of afterload rather than preload, which in turn suggests a beneficial effect of afterload reduction on oxidative stress in HF.


Assuntos
Benzazepinas/farmacologia , Insuficiência Cardíaca/tratamento farmacológico , Sistema Renina-Angiotensina/efeitos dos fármacos , Superóxido Dismutase/efeitos dos fármacos , Tetrazóis/farmacologia , Valina/análogos & derivados , Adulto , Idoso , Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Bloqueadores do Receptor Tipo 1 de Angiotensina II/farmacologia , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Benzazepinas/administração & dosagem , Estudos Cross-Over , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Humanos , Lipoproteínas LDL/efeitos dos fármacos , Lipoproteínas LDL/metabolismo , Masculino , Pessoa de Meia-Idade , Estresse Oxidativo/efeitos dos fármacos , Superóxido Dismutase/metabolismo , Tetrazóis/administração & dosagem , Valina/administração & dosagem , Valina/farmacologia , Valsartana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...