Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rep Pract Oncol Radiother ; 28(3): 416-428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795396

RESUMO

Background: The aim of this study was to indicate the most favorable - in terms of to the time of calculation and the uncertainty of determining the dose distribution - values of the parameters for the Electron Monte Carlo (eMC) algorithm in the Eclipse treatment planning system. Materials and methods: Using the eMC algorithm and the variability of the values of its individual parameters, calculations of the electron dose distribution in the full-scattering virtual water phantom were performed, obtaining percentage depth doses, beam profiles, absolute dose values in points and calculation times. The reference data included water tank measurements such as relative dose distributions and absolute point doses. Results: For 63 sets of calculation data created from selected values of the parameters for the eMC algorithm, calculation times were analyzed and the absolute calculated and measured doses were compared. Performing a statistical analysis made it possible to determine whether the differences in the values of deviations between the actual dose and the calculated dose in individual regions of the percentage depth dose curve and the beam profile are statistically significant between the analyzed sets of parameters. Conclusions: Taking into account obtained results from the analysis of the discrepancy between the distribution of the calculated and measured dose, the correspondence of the absolute value of the calculated and measured dose and the duration of the calculation of the dose distribution, the optimal set of parameters was indicated for the eMC algorithm which allows obtaining the dose distribution and the number of monitor units in an acceptable time.

2.
Rep Pract Oncol Radiother ; 27(2): 241-249, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36299384

RESUMO

Background: To properly configure a treatment planning system, a measurement data set is needed, which consists of the values required for its configuration. The aim is to obtain a dosimetric model of the beam that is as compatible as possible with the measured values. The set of required data can be supplemented with optional values. The aim of the study was to assess the influence of optional measurement data on the compliance of the calculations with the measurements. Materials and methods: Dosimetric measurements, model configuration and dose distribution calculations were performed for the photon radiation beams generated by the VMS TrueBeam® linear accelerator. Beams were configured on an Eclipse™ v. 15.6 system using the Acuros v. 15.6 algorithm. The measured and calculated data were entered into the Alfard™ software for comparison with the calculated dose distributions. In the last stage, the absolute dose values at the designated points were also compared. The obtained data were statistically analysed with Statistica™ v. 13.3. Results: The work showed that the differences in the shape of the beam profile, depth dose and the dose value in points were not related to the use of optional data. Differences in dose distributions are within the tolerance. It cannot be determined under which conditions the use of optional data has a more favourable effect on the reflection of the actual dose values. Conclusions: The use of optional data in modelling photon radiation beams does not significantly improve the compliance of the calculated and measured dose values.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...