Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Environ Microbiol ; 89(1): e0169922, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36511659

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a threat to human health. Acidic electrolyzed water (AEW) has recently been suggested to demonstrate virucidal activity. Many types of AEW with different pH values, generated by the electrolysis of different chemicals, such as sodium chloride, potassium chloride, and hydrochloric acid, are commercially available. In this study, we compared the virucidal activities of these types of AEW against SARS-CoV-2, including the ancestral strain and variant Alpha, Beta, Gamma, Delta, and Omicron strains. Virus solution (viral titer, 6.9 log10 50% tissue culture infective dose [TCID50]/mL) was mixed with AEW (free available chlorine concentration, 34.5 ppm) at mixing ratios of 1:9, 1:19, and 1:49. At mixing ratios of 1:9 and 1:19, AEW with a pH of 2.8 showed stronger virucidal activities than AEW with a pH of 4.1 to 6.5 against the SARS-CoV-2 ancestral strain in 20 s. From the strongest to the weakest virucidal activity, the AEW pH levels were as follows: pH 2.8, pH 4.1 to 5.4, pH 6.4 to 6.5. At a ratio of 1:49, the viral titers of viruses treated with all AEW solutions at pH 2.8 to 6.5 were almost below the detection limit, which was 1.25 log10 TCID50/mL. The virus inactivation efficiency of AEW was reduced in the presence of fetal bovine serum and other substances contained in the virus solution used in this study. AEW with pH values of 2.8 to 6.5 showed virucidal activity against all of the tested SARS-CoV-2 strains, including the ancestral and variant strains. These results provide useful knowledge for the effective application of AEW as a SARS-CoV-2 disinfectant. IMPORTANCE Acidic electrolyzed water (AEW) demonstrates virucidal activity against multiple viruses. Since AEW exhibits low toxicity, is inexpensive, and is environmentally friendly, it can be a useful disinfectant against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although the pH values of currently available AEW products vary, the impact of different pH values on SARS-CoV-2 inactivation has not previously been evaluated in detail. In this study, we compared the virucidal activities of multiple AEW solutions with different pH values, under the same experimental conditions. We found that AEW solutions with lower pH values demonstrated more potent virucidal activity. Also, we showed that the extent of virus inactivation by the AEW was based on the balance of the abundance of free available chlorine, virus, and other organic substances in the mixture. AEW exhibited rapid virucidal activity against multiple SARS-CoV-2 strains. This study demonstrated the usefulness of AEW as a disinfectant which can be applied to the inactivation of SARS-CoV-2.


Assuntos
COVID-19 , Desinfetantes , Humanos , SARS-CoV-2 , Cloro/química , Desinfetantes/farmacologia , Água/química , Ácidos , Concentração de Íons de Hidrogênio
2.
J Vet Med Sci ; 79(12): 1973-1977, 2017 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-29093278

RESUMO

Bovine mastitis causes significant economic losses in the dairy industry. Effective prevention of bovine mastitis requires an understanding of the infection status of a pathogenic microorganism in a herd that has not yet shown clinical signs of mastitis and appropriate treatment specific for the pathogenic microorganism. However, bacterial identification by culture has drawbacks in that the sensitivity may be low and the procedure can be complex. In this study, we developed a genetic detection method to identify mastitis pathogens using a simple and highly sensitive electrochemical DNA chip which can specifically detect bacterial DNA in milk specimens. First, we selected microorganisms belonging to 12 families and/or genera associated with mastitis for which testing should be performed. Next, we optimized the conditions for amplifying microorganism DNA by loop-mediated isothermal amplification (LAMP) using 32 primers and the use of a DNA chip capable of measuring all pathogens simultaneously. Sample detection could be completed in just a few hours using this method. Comparison of the results obtained with our DNA chip method and those obtained by bacterial culture verified that when the culture method was set to 100%, the total positive concordance rate of the DNA chip was 85.0% and the total negative concordance rate was 86.9%. Furthermore, the proposed method allows both rapid and highly sensitive detection of mastitis pathogens. We believe that this method will contribute to the development of an effective mastitis control program.


Assuntos
Mastite Bovina/microbiologia , Técnicas de Amplificação de Ácido Nucleico/veterinária , Animais , Bovinos , DNA Bacteriano , Feminino , Mastite Bovina/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Análise de Sequência com Séries de Oligonucleotídeos/veterinária
3.
J Vet Med Sci ; 77(8): 1007-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25843742

RESUMO

A rapid and efficient DNA extraction method was developed for detecting mastitis pathogens in milk. The first critical step involved cell wall disruption by bead-beating, as physical disruption using beads was more effective for DNA extraction from Gram-positive bacteria, such as Staphylococcus aureus, than enzymatic disruption using proteinase K. The second critical step involves the use of acetic acid and ammonium sulfate in the purification process, as these reagents effectively and efficiently remove the lipids and proteins in milk. Using these methods, DNA suitable for loop-mediated isothermal amplification was obtained within 30 min. Also, the rapid and sensitive detection of S. aureus in milk was possible at levels as low as 200 cfu/ml.


Assuntos
DNA Bacteriano/isolamento & purificação , Mastite Bovina/microbiologia , Leite/química , Infecções Estafilocócicas/veterinária , Staphylococcus aureus/genética , Animais , Bovinos , Feminino , Mastite Bovina/diagnóstico , Leite/microbiologia , Técnicas de Amplificação de Ácido Nucleico/veterinária , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia
4.
PLoS One ; 9(5): e97787, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24858917

RESUMO

High prevalence of infection with high-risk human papilloma virus (HPV) ranging from 25 to 100% (average 31%) was observed in breast cancer (BC) patients in Singapore using novel DNA chip technology. Early stage of BC demonstrated higher HPV positivity, and BC positive for estrogen receptor (ER) showed significantly higher HPV infection rate. This unique association of HPV with BC in vivo prompted us to investigate a possible involvement of HPV in early stages of breast carcinogenesis. Using normal breast epithelial cells stably transfected with HPV-18, we showed apparent upregulation of mRNA for the cytidine deaminase, APOBEC3B (A3B) which is reported to be a source of mutations in BC. HPV-induced A3B overexpression caused significant γH2AX focus formation, and DNA breaks which were cancelled by shRNA to HPV18 E6, E7 and A3B. These results strongly suggest an active involvement of HPV in the early stage of BC carcinogenesis via A3B induction.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/virologia , Carcinogênese , Citidina Desaminase/metabolismo , Papillomaviridae/fisiologia , Adulto , Idoso , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/metabolismo , Transformação Celular Viral , Citidina Desaminase/deficiência , Citidina Desaminase/genética , Feminino , Regulação Neoplásica da Expressão Gênica , Técnicas de Silenciamento de Genes , Instabilidade Genômica , Células HEK293 , Humanos , Glândulas Mamárias Humanas/metabolismo , Glândulas Mamárias Humanas/patologia , Pessoa de Meia-Idade , Antígenos de Histocompatibilidade Menor , Prognóstico , Receptores de Estrogênio/metabolismo , Fatores de Tempo
5.
Exp Anim ; 63(2): 169-73, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24770642

RESUMO

Prevalence of Helicobacter is mostly unknown in laboratory animals in Thailand. The 221 mice feces/cecum from 8 universities, 2 pharmaceutical companies and 3 research institutions in Thailand were surveyed for the prevalence and distribution of Helicobacter species by using the Electrochemical DNA chip. Helicobacter were detected 23/46 samples in Specific Pathogen Free (SPF) and 168/175 in conventional condition. Prevalence of Helicobacter were 98%, 96%, 92% and 78% in South (n=40), Northeast (n=40), North (n=25) and Central area (n=116), respectively. Only Central area holds SPF facility resulting in Helicobacter prevalence that seems to be lower than other areas. Three species of Helicobacter were detected in feces/cecum samples by sequence analysis: H. rodentium (67.0%, 148 samples), Helicobacter sp. MIT 01-6451 (15.4%, 34 samples), and unidentified Helicobacter species (14.1%, 9 samples). The results suggested that H. rodentium is the most common species of Helicobacter in laboratory mice in Thailand.


Assuntos
Animais de Laboratório/microbiologia , Helicobacter/isolamento & purificação , Laboratórios/estatística & dados numéricos , Animais , Ceco/microbiologia , Fezes/microbiologia , Helicobacter/patogenicidade , Camundongos/microbiologia , Análise de Sequência com Séries de Oligonucleotídeos , Prevalência , Organismos Livres de Patógenos Específicos , Tailândia/epidemiologia
6.
Asian Pac J Cancer Prev ; 13(4): 1151-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22799297

RESUMO

High-risk human papillomavirus (HPV) genotypes are the major cause of cervical cancer. Hence, HPV genotype detection is a helpful preventive measure to combat cervical cancer. Recently, several HPV detection methods have been developed, each with different sensitivities and specificities. The objective of this study was to compare HPV high risk genotype detection by an electrochemical DNA chip system, a line probe assay (INNO- LiPA) and sequencing of the L1, E1 regions. A total of 361 cervical smears with different cytological findings were subjected to polymerase chain reaction-sequencing and electrochemical DNA chip assessment. Multiple infections were found in 21.9% (79/361) of the specimens, most prevalently in 20-29-year olds while the highest prevalence of HPV infection was found in the 30-39-year age group. The most prevalent genotype was HPV 16 at 28.2% (138/489) followed by HPV 52 at 9.6% (47/489), with the other types occurring at less than 9.0%. The electrochemical DNA chip results were compared with INNO-LiPA and sequencing (E1 and L1 regions) based on random selection of 273 specimens. The results obtained by the three methods were in agreement except for three cases. Direct sequencing detected only one predominant genotype including low risk HPV genotypes. INNO-LiPA identified multiple infections with various specific genotypes including some unclassified-risk genotypes. The electrochemical DNA chip was highly accurate, suitable for detection of single and multiple infections, allowed rapid detection, was less time-consuming and was easier to perform when compared with the other methods. It is concluded that for clinical and epidemiological studies, all genotyping methods are perfectly suitable and provide comparable results.


Assuntos
Carcinoma in Situ/virologia , DNA Viral/análise , Análise de Sequência com Séries de Oligonucleotídeos , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Neoplasias do Colo do Útero/virologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma in Situ/patologia , Colo do Útero/virologia , Sondas de DNA de HPV , Técnicas Eletroquímicas , Feminino , Genótipo , Técnicas de Genotipagem , Humanos , Pessoa de Meia-Idade , Papillomaviridae/isolamento & purificação , Reação em Cadeia da Polimerase , Neoplasias do Colo do Útero/patologia , Adulto Jovem
7.
Anal Biochem ; 419(2): 190-5, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21925478

RESUMO

We have developed a novel multisample detection system by employing a technology combining a tag insertion primer and an electrochemical DNA chip. In the first application, Helicobacter species-infected mouse samples were detected. The primers that insert a different tag sequence in each sample were prepared, and loop-mediated isothermal amplification (LAMP) reaction was carried out. Then amplification products in which a part of the sequence was different in each sample could be obtained. The target sample in which these amplification products were mixed was injected into a cassette that included the DNA chip with immobilized probes. After the cassette was set in the DNA detection system, Genelyzer, the processes of hybridization, washing, and detection were performed by the system automatically. The positive and negative concordance rates of the existing nested polymerase chain reaction (PCR) method and this method were 100% (40/40 samples) and 97.3% (117/120 samples), respectively. This is a simple high-throughput method. Moreover, the cost per sample can be drastically lowered. Therefore, it is expected to contribute to the diagnosis of infectious agents in humans and animals.


Assuntos
Primers do DNA/metabolismo , Técnicas Eletroquímicas/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Animais , Sequência de Bases , Helicobacter/genética , Camundongos , Dados de Sequência Molecular , Reação em Cadeia da Polimerase , RNA Ribossômico 16S/genética , Reprodutibilidade dos Testes , Alinhamento de Sequência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA