Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 51(7): B121-9, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22410909

RESUMO

Taking advantage of the specific characteristics of a transversely excited atmospheric (TEA) CO(2) laser, a sophisticated technique for the analysis of chromated copper arsenate (CCA) in wood samples has been developed. In this study, a CCA-treated wood sample with a dimension of 20 mm × 20 mm and a thickness of 2 mm was attached in contact to a nickel plate (20 mm × 20 mm × 0.15 mm), which functions as a subtarget. When the TEA CO(2) laser was successively irradiated onto the wood surface, a hole with a diameter of approximately 2.5 mm was produced inside the sample and the laser beam was directly impinged onto the metal subtarget. Strong and stable gas plasma with a very large diameter of approximately 10 mm was induced once the laser beam had directly struck the metal subtarget. This gas plasma then interacted with the fine particles of the sample inside the hole and finally the particles were effectively dissociated and excited in the gas plasma region. By using this technique, high precision and sensitive analysis of CCA-treated wood sample was realized. A linear calibration curve of Cr was successfully made using the CCA-treated wood sample. The detection limits of Cr, Cu, and As were estimated to be approximately 1, 2, and 15 mg/kg, respectively. In the case of standard LIBS using the Nd:YAG laser, the analytical intensities fluctuate and the detection limit was much lower at approximately one-tenth that of TEA CO(2) laser.


Assuntos
Lasers de Gás , Lasers de Estado Sólido , Análise Espectral/métodos , Madeira/química , Arseniatos/análise , Cromo/análise , Cobre/análise , Limite de Detecção
2.
Anal Bioanal Chem ; 400(10): 3279-87, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21400079

RESUMO

A novel method for the direct and sensitive analysis of powder samples has been developed by utilizing the characteristics of a transversely excited atmospheric (TEA) CO(2) laser. In this study, a powder sample was placed in a container and covered by a metal mesh; the metal mesh functions to control the blowing-off of the powder. The container was then perpendicularly attached on a metal surface. When a TEA CO(2) laser (1.5 J, 200 ns) was focused on the metal surface, a large hemispherical gas plasma (radius of around 8 mm) with long emission lifetime (several tens of microseconds) was produced without ablating the metal surface. The high-speed expansion force of the gas plasma samples the powder covered by the metal mesh and fine powder particles are sent into the gas plasma region to be dissociated and excited. Sensitive semi-quantitative analysis was made on organic powder samples such as powdered rice, starch, seaweed (agar), and supplements. The detection limit of heavy metals of Cr in powdered mineral supplement was approximately 0.55 mg/kg.


Assuntos
Análise de Alimentos , Lasers , Pós/análise , Cromo/análise , Suplementos Nutricionais/análise , Limite de Detecção , Metais Pesados/análise , Oryza/química , Pressão , Alga Marinha/química , Amido/análise
3.
Appl Spectrosc ; 64(4): 365-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20412619

RESUMO

An experimental study of ultraviolet (UV) laser-induced plasma spectroscopy (LIPS) on Ti samples with low-pressure surrounding He gas has been carried out to demonstrate its applicability to quantitative micro-analysis of deuterium impurities in titanium without the spectral interference from the ubiquitous surface water. This was achieved by adopting the optimal experimental condition ascertained in this study, which is specified by 5 mJ laser energy, 10 Torr helium pressure, and 1-50 mus measurement window, which resulted in consistent D emission enhancement and effective elimination of spectral interference from surface water. As a result, a linear calibration line exhibiting a zero intercept was obtained from Ti samples doped with various D impurity concentrations. An additional measurement also yielded a detection limit of about 40 ppm for D impurity, well below the acceptable threshold of damaging H concentration in Ti and its alloys. Each of these measurements was found to produce a crater size of only 25 mum in diameter, and they may therefore qualify as nondestructive measurements. The result of this study has therefore paved the way for conducting further experiments with hydrogen-doped Ti samples and the technical implementation of quantitative micro-analysis of detrimental hydrogen impurity in Ti metal and its alloys, which is the ultimate goal of this study.

4.
Appl Opt ; 46(34): 8298-304, 2007 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18059672

RESUMO

This experiment was carried out to address the need for overcoming the difficulties encountered in hydrogen analysis by means of plasma emission spectroscopy in atmospheric ambient gas. The result of this study on zircaloy-4 samples from a nuclear power plant demonstrates the possibility of attaining a very sharp emission line from impure hydrogen with a very low background and practical elimination of spectral contamination of hydrogen emission arising from surface water and water vapor in atmospheric ambient gas. This was achieved by employing ultrapure ambient helium gas as well as the proper defocusing of the laser irradiation and a large number of repeated precleaning laser shots at the same spot of the sample surface. Further adjustment of the gating time has led to significant reduction of spectral width and improvement of detection sensitivity to ~50 ppm. Finally, a linear calibration curve was also obtained for the zircaloy-4 samples with zero intercept. These results demonstrate the feasibility of this technique for practical in situ and quantitative analysis of hydrogen impurity in zircaloy-4 tubes used in a light water nuclear power plant.

5.
Anal Chem ; 79(7): 2703-7, 2007 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-17341055

RESUMO

It is found in this work that variation of laser power density in low-pressure plasma spectrochemical analysis of hydrogen affects sensitively the hydrogen emission intensity from the unwanted and yet ubiquitous presence of ambient water. A special experimental setup has been devised to allow the simple condition of focusing/defocusing the laser beam on the sample surface. When applied to zircaloy-4 samples prepared with various hydrogen impurity concentrations using low-pressure helium surrounding gas, good-quality hydrogen emission lines of very high signal to background ratios were obtained with high reproducibility under weakly focused or largely defocused laser irradiation. These measurements resulted in a linear calibration line with nonzero intercept representing the residual contribution from the recalcitrant water molecules. It was further shown that this can be evaluated and taken into account by means of the measured intensity ratio between the oxygen and zirconium emission lines. We have demonstrated the applicability of this experimental approach for quantitative determination of hydrogen impurity concentrations in the samples considered.


Assuntos
Hidrogênio/análise , Lasers , Ressonância de Plasmônio de Superfície/métodos , Zircônio/química , Calibragem , Pressão , Sensibilidade e Especificidade , Ressonância de Plasmônio de Superfície/instrumentação , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...