Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Math Biol ; 86(5): 73, 2023 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-37039885

RESUMO

In this paper, we study a stochastic parabolic problem that emerges in the modeling and control of an electrically actuated MEMS (micro-electro-mechanical system) device. The dynamics under consideration are driven by an one dimensional fractional Brownian motion with Hurst index [Formula: see text]. We derive conditions under which the resulting SPDE has a global in time solution, and we provide analytic estimates for certain statistics of interest, such as quenching times and the corresponding quenching probabilities. Our results demonstrate the non-trivial impact of the fractional noise on the dynamics of the system. Given the significance of MEMS devices in biomedical applications, such as drug delivery and diagnostics, our results provide valuable insights into the reliability of these devices in the presence of positively correlated noise.


Assuntos
Sistemas Microeletromecânicos , Sistemas Microeletromecânicos/métodos , Reprodutibilidade dos Testes , Movimento (Física)
2.
Int J Radiat Biol ; 97(3): 421-430, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33264581

RESUMO

PURPOSE: The effects of the electromagnetic (EM) radiation emitted by a mobile phone on the central auditory system of rabbits are investigated in this paper. Auditory brainstem response (ABR) measurements were performed before and after short-term exposure to EM radiation. MATERIALS AND METHODS: Excitation was provided by a GSM-1800 emitter placed in contact with the (randomly selected) ear of the anesthetized rabbit/subject. The latency of waves I, II, III, IV, V and the interpeak latencies I-III, I-V, III-V were recorded, for both ears, before (baseline recordings) and after 1, 15, 30, 45 and 60 minutes of exposure to the EM radiation. The repeated measures one-way analysis of variance (ANOVA) followed by the post hoc Tukey test for pairwise comparisons was performed in order to decide about the significance of the results. RESULTS: The statistical tests indicated that, as regards the ear ipsilateral to the radiating module, the mean latencies of waves I, II, III, IV, V, I-III, I-IV after 60 min exposure, the mean latencies of waves I, III, IV, V, I-III, I-IV after 45 min exposure and the mean latencies of waves I, III, IV, V, I-IV after 30 min exposure, were significantly prolonged compared to the corresponding baseline values. Statistically significant differences were also found for certain peak and interpeak latencies for 60 min exposure as compared with the corresponding results for 1 min and 15 min exposure. No statistically significant delay was observed for the latencies before and after the exposure, for the ear contralateral to the radiation source. CONCLUSIONS: Although we found that more than 30 min exposure to GSM-1800 radiation resulted in prolongation of certain ABR components of rabbits, further investigation may be needed into the potential adverse effects on the auditory pathways.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Potenciais Evocados Auditivos do Tronco Encefálico/efeitos da radiação , Animais , Coelhos , Tempo de Reação/efeitos da radiação
3.
BMC Musculoskelet Disord ; 8: 89, 2007 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-17850663

RESUMO

BACKGROUND: Several studies have been carried out in order to investigate the effect of ankle bracing on ankle joint function and performance. However, no study so far has examined the role of skin-brace interface pressure in neuromuscular control. The aim of this study was to investigate the effect of different skin-ankle brace interface pressures on quiet single limb balance and the electromyographic (EMG) activation sequence of four lower limb muscles. METHODS: Thirty three male physical education students who volunteered to take part in the study were measured under three ankle brace conditions: i) without brace, ii) with brace and 30 kPa application pressure and iii) with brace and 60 kPa application pressure. Single limb balance (anteroposterior and mediolateral parameter) was assessed on the dominant lower limb, with open and closed eyes, on a force platform, simultaneously with the EMG recording of four lower lower limb muscles' (gastrocnemius, peroneus longus, rectus femoris and biceps femoris) activation onset. RESULTS: The results showed that overall balance (total stability parameter) was not significantly affected in any of the three ankle brace conditions. However, the anteroposterior centre of pressure excursion and centre of pressure excursion velocity were significantly increased with the application of ankle brace, both with 30 and 60 kPa application pressures. Furthermore, it was found that single limb balance was significantly worse with closed eyes compared to open eyes. EMG measurements showed that the sequence of lower limb activation onset was not affected in any of the three ankle brace application conditions. The results of this study showed that the application of an ankle brace with two different skin-brace interface pressures had no effect on overall single limb balance and the sequence of lower limb muscle activation. CONCLUSION: These findings suggest that peripheral joint receptors are either not adequately stimulated by the brace application and therefore are not able to alter the balance control strategy of the CNS, or that they play a less important role in the control of single limb balance. Further research is needed in this area with more dynamic and functional measurements, before the safe use of ankle bracing can be widely recommended.


Assuntos
Articulação do Tornozelo/fisiologia , Braquetes/efeitos adversos , Perna (Membro)/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Equilíbrio Postural/fisiologia , Adulto , Braquetes/normas , Eletromiografia/métodos , Retroalimentação/fisiologia , Humanos , Masculino , Força Muscular/fisiologia , Pressão/efeitos adversos , Propriocepção/fisiologia , Desempenho Psicomotor/fisiologia , Músculo Quadríceps/fisiologia , Fenômenos Fisiológicos da Pele , Tato/fisiologia
SELEÇÃO DE REFERÊNCIAS