1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38270501

RESUMO

A single radio frequency bucket of the 88-Inch Cyclotron is filled using a fast chopper located in the axial line. The bucket then accelerates until it reaches the deflector, at which point, it is extracted as a train of bunches. This phenomenon can be attributed to the characteristic multi-turn extraction of the cyclotron and, by simplifying the complex dynamics of a cyclotron, corresponds to the conceptual transfer function of the cyclotron. The confirmation of the single radio frequency bucket injection was achieved by operating the cyclotron in the third harmonic mode and observing the absence of intermediate bunches during the multiple-bunch extraction.

2.
Phys Med Biol ; 61(15): 5621-38, 2016 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-27385261

RESUMO

The potential of particle therapy due to focused dose deposition in the Bragg peak has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying the location of the Bragg peak onto a standard ultrasound image. Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the cyclotron inflector. The chopper limited the train of bunches so that 2 Gy were delivered in [Formula: see text]. The ion pulse generated thermoacoustic pulses that were detected by a cardiac ultrasound array, which also produced a grayscale ultrasound image. A filtered backprojection algorithm focused the received signal to the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Phantom experiments performed with the cavity both empty and filled with olive oil confirmed that displacement of the Bragg peak due to anatomical change could be detected. Thermoacoustic range measurements in the waterbath agreed with Monte Carlo simulation within 1.2 mm. In the phantom, thermoacoustic range estimates and first-order range estimates from CT images agreed to within 1.5 mm.


Assuntos
Acústica , Processamento de Imagem Assistida por Computador/métodos , Temperatura , Ultrassonografia/instrumentação , Algoritmos , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...