Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(10): 103540, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319310

RESUMO

We propose a combined use of a Pockels electro-optic sensor with a pickup loop coil (Bdot probe) for the measurement of magnetic fluctuations in plasmas. In this method, induced fluctuating voltage on the coil loop is converted into an optical signal by a compact electro-optic sensor in the vicinity of the measurement point and is transferred across optical fiber that is unaffected by electric noise or capacitive load issues. Compared with conventional Bdot probes, the electro-optic Bdot probe (1) is electrically isolated and free from noise pickup caused by the metallic transmission line and (2) can be operated at a higher-frequency range because of the smaller capacitance of the operation circuit, both of which are suitable for many plasma experiments. Conversely, the sensitivity of the current electro-optic Bdot probe arrangement is still significantly lower than that of conventional Bdot probes. A preliminary measurement result with the electro-optic Bdot probe showed the detection of a magnetic fluctuation signal around the cyclotron frequency range in the RT-1 magnetospheric plasma experiment.

2.
Sci Rep ; 12(1): 5507, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35365747

RESUMO

Self-organized structure formation in magnetically confined plasmas is one of the most attractive subjects in modern experimental physics. Nonequilibrium media are known to often exhibit phenomena that cannot be predicted by superposition of linear theories. One representative example of such phenomena is the hydrogen isotope effect in fusion plasmas, where the larger the mass of the hydrogen isotope fuel is the better the plasma confinement becomes, contrary to what simple scaling models anticipate. In this article, threshold condition of a plasma structure formation is shown to have a strong hydrogen isotope effect. To investigate the underlying mechanism of this isotope effect, the electrostatic potential is directly measured by a heavy ion beam probe. It is elucidated that the core electrostatic potential transition occurs with less input power normalized by plasma density in plasmas with larger isotope mass across the structure formation. This observation is suggestive of the isotope effect in the radial electric field structure formation.

3.
Rev Sci Instrum ; 92(3): 034711, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820101

RESUMO

A six-pole Q-band waveguide filter with a notch frequency above the Q-band has been developed for plasma diagnostics. The previous paper [Nishiura et al., J. Instrum. 10, C12014 (2015)] reported that the notch frequency exists within the standard band. In this study, the newly required notch filter extends the function, which prevents a thorny wave from being mixed into an instrument beyond the standard bandwidth of the waveguide. The mode control technique for cavities realizes a deep and sharp filter shape for Q-band notch filters with 56 and 77 GHz notches, respectively. The former filter has an attenuation more than 50 dB at 56.05 GHz and a bandwidth of 1.1 GHz at -3 dB. The latter filter has an attenuation more than 55 dB at 76.95 GHz and a bandwidth of 1.6 GHz at -3 dB. The electron cyclotron emission imaging and the electron cyclotron emission (ECE) diagnostics for the Q-band implemented a pair of the fabricated filters and demonstrated the ECE measurement successfully in the intense stray radiation from a 56 GHz gyrotron.

4.
Rev Sci Instrum ; 91(3): 033503, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32260004

RESUMO

We are developing a laser ion source to provide a high brightness multi-charged heavy ion beam as a part of the heavy ion beam probe system, which will be used to diagnose plasma potential in the Ring Trap 1 device at the University of Tokyo. As a probe beam, Nb2+ was selected, and a detailed laser irradiation condition was explored. It was found that the laser power density of 1.2 × 109 W/cm2 gives the maximum particle number of Nb2+ per laser energy from a niobium foil target. Essential ablation plasma parameters to design the laser ion source were also obtained. The expected beam current was more than 12 mA/cm2, with a pulse width of 3.1 µs at 200 mm away from the target.

5.
Rev Sci Instrum ; 89(10): 10C101, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399734

RESUMO

A new Nd:YAG laser Thomson scattering (TS) system has been developed to explore the mechanism of high-beta plasma formation in the RT-1 device. The TS system is designed to measure electron temperatures (Te) from 10 eV to 50 keV and electron densities (ne) of more than 1.0 × 1017 m-3. To measure at the low-density limit, the receiving optics views the long scattering length (60 mm) using a bright optical system with both a large collection window (260-mm diameter) and large collection lenses (300-mm diameter, a solid angle of ∼68 × 10-3 str). The scattered light of the 1.2-J Nd:YAG laser (repetition frequency: 10 Hz) is detected with a scattering angle of 90° and is transferred via a set of lenses and an optical fiber bundle to a polychromator. After Raman scattering measurement for the optical alignment and an absolute calibration, we successfully measured Te = 72.2 eV and ne = 0.43 × 1016 m-3 for the coil-supported case and Te = 79.2 eV and ne = 1.28 × 1016 m-3 for the coil-levitated case near the inner edge in the magnetospheric plasmas.

6.
Rev Sci Instrum ; 89(10): 10D133, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399835

RESUMO

A coherence-imaging spectroscopy (CIS) technique was developed to investigate plasma confinement in a dipole system that imitates a planetary magnetosphere. Optical interference generated using birefringent crystals enables two-dimensional Doppler spectroscopy to measure ion temperatures and flow velocities in plasmas. CIS covers the entire dynamics of the pole areas as well as of the core and edge areas on a dipole confinement device. The two-dimensional visualization of these quantities in the magnetospheric-plasma device RT-1 was demonstrated using CIS.

7.
Rev Sci Instrum ; 88(2): 023501, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28249485

RESUMO

The direct measurements of high-frequency electric fields in a plasma bring about significant advances in the physics and engineering of various waves. We have developed an electro-optic sensor system based on the Pockels effect. Since the signal is transmitted through an optical fiber, the system has high tolerance for electromagnetic noises. To demonstrate its applicability to plasma experiments, we report the first result of measurement of the ion-cyclotron wave excited in the RT-1 magnetosphere device. This study compares the results of experimental field measurements with simulation results of electric fields in plasmas.

8.
Rev Sci Instrum ; 87(11): 11E731, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910473

RESUMO

Two-dimensional spatial profiles of potential fluctuation were measured with the heavy ion beam probe (HIBP) in the Large Helical Device (LHD). For 2D spatial profile measurements, the probe beam energy has to be changed, which requires the adjustment of many deflectors in the beam transport line to optimize the beam trajectory, since the transport line of LHD-HIBP system is long. The automatic beam adjustment system was developed, which allows us to adjust the beam trajectory easily. By analyzing coherence between potential fluctuation and magnetic probe signal, the noise level of the mode power spectrum of the potential fluctuation can be reduced. By using this method, the 2D spatial profile of potential fluctuation profile was successfully obtained.

9.
Phys Rev E ; 94(4-1): 043203, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27841504

RESUMO

We study the behavior of high-energy positrons emitted from a radioactive source in a magnetospheric dipole field configuration. Because the conservation of the first and second adiabatic invariants is easily destroyed in a strongly inhomogeneous dipole field for high-energy charged particles, the positron orbits are nonintegrable, resulting in chaotic motions. In the geometry of a typical magnetospheric levitated dipole experiment, it is shown that a considerable ratio of positrons from a ^{22}Na source, located at the edge of the confinement region, has chaotic long orbit lengths before annihilation. These particles make multiple toroidal circulations and form a hollow toroidal positron cloud. Experiments with a small ^{22}Na source in the Ring Trap 1 (RT-1) device demonstrated the existence of such long-lived positrons in a dipole field. Such a chaotic behavior of high-energy particles is potentially applicable to the formation of a dense toroidal positron cloud in the strong-field region of the dipole field in future studies.

10.
Rev Sci Instrum ; 87(2): 02B107, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931989

RESUMO

Wavelength spectra of Balmer-α light from plasmas in the extraction region of the Large Helical Device-R&D negative ion source, or the LHD one-third ion source have exhibited a blue shift as a negative bias voltage was applied to the plasma grid. The blue shift increased as the negative bias voltage with respect to the local plasma potential was increased. The measured spectra were compared with the velocity distributions of surface reflected hydrogen atoms calculated by atomic collisions in amorphous target code. The arc power and the source H2 pressure also affected the shift and broadening in the observed Balmer-α spectra. The possibility of identifying the negative hydrogen ions produced at the low work function plasma grid surface by high resolution spectroscopy is discussed.

11.
Phys Rev Lett ; 116(1): 015002, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26799023

RESUMO

Abrupt and strong excitation of a mode has been observed when the frequency of a chirping energetic-particle driven geodesic acoustic mode (EGAM) reaches twice the geodesic acoustic mode (GAM) frequency. The frequency of the secondary mode is the GAM frequency, which is a half-frequency of the primary EGAM. Based on the analysis of spatial structures, the secondary mode is identified as a GAM. The phase relation between the secondary mode and the primary EGAM is locked, and the evolution of the growth rate of the secondary mode indicates nonlinear excitation. The results suggest that the primary mode (EGAM) contributes to nonlinear destabilization of a subcritical mode.

12.
J Oral Rehabil ; 42(12): 900-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26147313

RESUMO

The aim of this study was to record oral vestibule pressure (OVP) by the lip and cheek contraction during gum chewing, to examine the characteristics of these pressures and coordination between the OVP and jaw movement. The subjects were eight healthy adult men (mean age of 29·3 ± 3·3 years). An experimental plate that incorporated four pressure sensors on the midline of the upper jaw (Ch. 1), upper right canine (Ch. 2), upper right first molar (Ch. 3) and upper left first molar (Ch. 4) was used for measuring OVP. The right masseter electromyogram (EMG) was recorded simultaneously. Subjects chewed gum on the right side 20 times, and eight consecutive strokes were used for the analysis of the sequential order, maximal magnitude and duration of each OVP. Onset of OVP was observed at the molar on the non-chewing side (Ch. 4) before chewing side (Ch. 3), and offset was largely simultaneous at each site. On the chewing side (Chs. 1-3), OVP onset during the interval of EMG activity reached to the peak around the end of interval and offset in the duration of EMG activity. The maximal pressure was significantly larger at Chs. 1-3 than at Ch. 4, but no significant differences were observed in duration of pressure among each site. These results suggest that OVP is coordinated with jaw movement during gum chewing, and larger pressure is produced on the chewing side than on the non-chewing side. Our findings are quantitative indices for the evaluation of lip and cheek function during mastication.


Assuntos
Goma de Mascar , Músculo Masseter/fisiologia , Mastigação/fisiologia , Adulto , Bochecha/fisiologia , Eletromiografia , Voluntários Saudáveis , Humanos , Lábio/fisiologia , Masculino , Modelos Dentários , Pressão
13.
Rev Sci Instrum ; 85(11): 11D853, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430266

RESUMO

Two-dimensional potential profiles in the Large Helical Device (LHD) were measured with heavy ion beam probe (HIBP). To measure the two-dimensional profile, the probe beam energy has to be changed. However, this task is not easy, because the beam transport line of LHD-HIBP system is very long (∼20 m), and the required beam adjustment consumes much time. To reduce the probe beam energy adjustment time, an automatic beam adjustment system has been developed. Using this system, required time to change the probe beam energy is dramatically reduced, such that two-dimensional potential profiles were able to be successfully measured with HIBP by changing the probe beam energy shot to shot.

14.
Rev Sci Instrum ; 85(11): 11E804, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430369

RESUMO

A 12 × 12 pixel detector has been developed and used in a laboratory experiment for lost fast-ion diagnostics. With gamma rays in the MeV range originating from nuclear reactions (9)Be(α, nγ)(12)C, (9)Be(d, nγ)(12)C, and (12)C(d, pγ)(13)C, a high purity germanium (HPGe) detector measured a fine-energy-resolved spectrum of gamma rays. The HPGe detector enables the survey of background-gamma rays and Doppler-shifted photo peak shapes. In the experiments, the pixel detector produces a gamma-ray image reconstructed from the energy spectrum obtained from total photon counts of irradiation passing through the detector's lead collimator. From gamma-ray image, diagnostics are able to produce an analysis of the fast ion loss onto the first wall in principle.

15.
Rev Sci Instrum ; 85(11): 11E811, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430376

RESUMO

A control system for a fast steering mirror has been newly developed for the electron cyclotron heating (ECH) launchers in the large helical device. This system enables two-dimensional scan during a plasma discharge and provides a simple feedback control function. A board mounted with a field programmable gate array chip has been designed to realize feedback control of the ECH beam position to maintain higher electron temperature by ECH. The heating position is determined by a plasma diagnostic signal related to the electron temperature such as electron cyclotron emission and Thomson scattering.

16.
Rev Sci Instrum ; 85(2): 02A720, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593454

RESUMO

We study influence of electric field penetration into H(-) ion source plasma with three-electrode beam extraction system. Clear change in the plasma potential due to the field penetration is observed in case of low gap voltage between a plasma electrode and an extraction electrode. Influence of lens voltage on the second electrode, which is normally utilized to focus the extracted beam, on ion source plasma is evaluated separating contributions of H(-) density in the plasma and extraction probability of H(-) ions from the plasma by two kinds of photodetachment techniques. In our operation condition, we found that the lens voltage is also useful to enhance the H(-) density in the plasma, though it negatively affects the extraction probability.

17.
Rev Sci Instrum ; 85(2): 02B132, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593572

RESUMO

The plasma electrode structure of a 14 GHz ECR ion source was modified to enlarge the plasma volume of low electron temperature region. The result shows that the extracted beam current reached about 0.6 mA/cm(2) with about 40 W microwave power. To investigate the correlation between the volume of the low electron temperature region and the H(-) current, a vacuum ultraviolet (VUV) spectrometer had been installed to observe light emission in the VUV wavelength range from the plasma. From the results of the negative ion beam current and that from VUV spectrometry, production rate of vibrationally excited hydrogen molecule seems to be enhanced by increasing the volume of low electron temperature region.


Assuntos
Ciclotrons/instrumentação , Elétrons , Hidrogênio/química , Eletrodos , Espectrofotometria Ultravioleta , Vácuo
18.
Rev Sci Instrum ; 85(2): 02C311, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593648

RESUMO

Angle-resolved energy distribution functions of positive and negative hydrogen ions produced from a rough-finished Si surface under 1 keV proton irradiation have been measured. The corresponding distribution from a crystalline surface and a carbon surface are also measured for comparison. Intensities of positive and negative ions from the rough-finished Si are substantially smaller than those from crystalline Si. The angular distributions of these species are broader for rough surface than the crystalline surface. No significant temperature dependence for positive and negative ion intensities is observed for all samples in the temperature range from 300 to 400 K.


Assuntos
Carbono/química , Hidrogênio/química , Fenômenos Ópticos , Silício/química , Temperatura , Propriedades de Superfície
19.
Rev Sci Instrum ; 83(10): 10D731, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126903

RESUMO

Collective Thomson scattering (CTS) diagnostic requires a strong probing beam to diagnose a bulk and fast ion distribution function in fusion plasmas. A mega-watt gyrotron for electron cyclotron resonance heating is used as a probing beam in the large helical device. Spurious mode oscillations are often observed during the turning on/off phase of the modulation. The frequency spectra of the 77-GHz gyrotron output power have been measured, and then one of the spurious modes, which interferes with the CTS receiver system, is identified as the TE(17,6) mode at the frequency of 74.7 GHz. The mode competition calculation indicates that the increase of the magnetic field strength at the gyrotron resonator can avoid such a spurious mode and excite only the main TE(18,6) mode. The spurious radiation at the 74.7 GHz is experimentally demonstrated to be suppressed in the stronger magnetic field than that optimized for the high-power operation.

20.
Rev Sci Instrum ; 83(2): 02A716, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380225

RESUMO

A pair of permanent magnets has formed enough intensity to realize electron cyclotron resonance condition for a 14 GHz microwave in a 2 cm diameter 9 cm long alumina discharge chamber. A three-electrode extraction system assembled in a magnetic shielding has formed a stable beam of negative hydrogen ions (H(-)) in a direction perpendicular to the magnetic field. The measured H(-) current density was about 1 mA∕cm(2) with only 50 W of discharge power, but the beam intensity had shown saturation against further increase in microwave power. The beam current decreased monotonically against increasing pressure.


Assuntos
Hidrogênio/química , Micro-Ondas , Radiometria/instrumentação , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...