Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 49(6): 1583-1586, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489456

RESUMO

We report on the demonstration of a diode-pumped, Tm:YLF-based, chirped pulse amplification laser system operating at λ ≈ 1.9 µm that produces amplified pulse energies exceeding 1.5 J using a single 8-pass power amplifier. The amplified pulses are subsequently compressed to sub-300 fs durations by a diffraction grating pair, producing record >1 TW peak power pulses. To the best of our knowledge, this is the highest peak power demonstrated for any solid-state, near-2 µm laser architecture and illustrates the potential of Tm:YLF for the next generation of high-power, diode-pumped ultrashort lasers.

2.
Opt Express ; 23(12): 15532-44, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-26193533

RESUMO

Precise assessment of the high fluence performance of pulse compressor gratings is necessary to determine the safe operational limits of short-pulse high energy lasers. We have measured the picosecond laser damage behavior of multilayer dielectric (MLD) diffraction gratings used in the compression of chirped pulses on the Advanced Radiographic Capability (ARC) kilojoule petawatt laser system at the Lawrence Livermore National Laboratory (LLNL). We present optical damage density measurements of MLD gratings using the raster scan method in order to estimate operational performance. We also report results of R-on-1 tests performed with varying pulse duration (1-30 ps) in air, and clean vacuum. Measurements were also performed in vacuum with controlled exposure to organic contamination to simulate the grating use environment. Results show sparse defects with lower damage resistance which were not detected by small-area damage test methods.

3.
Opt Lett ; 34(11): 1708-10, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19488156

RESUMO

We have developed improved cavity-finesse methods for characterizing the diffraction efficiencies of large gratings at the Littrow angle. These methods include measuring cavity length with optical techniques, using a Michelson interferometer to calibrate piezoelectric transducer nonlinearities and angle-tuning procedures to confirm optimal alignment. We used these methods to characterize two 20 cm scale dielectric gratings. The values taken from across their surfaces collectively had means and standard deviations of micro=99.293% and sigma=0.164% and micro=99.084% and sigma=0.079%. The greatest efficiency observed at a single point on a grating was (99.577+/-0.002)%, which is also the most accurate measurement of the diffraction efficiency in the literature of which we are aware. These results prove that a high diffraction efficiency with low variation is achievable across large apertures for gratings.

4.
Opt Lett ; 31(2): 155-7, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16441014

RESUMO

Future energy scaling of high-energy chirped-pulse amplification systems will benefit from the capability to coherently tile diffraction gratings into larger apertures. Design and operation of a novel, accurate alignment diagnostic for coherently tiled diffraction gratings is required for successful implementation of this technique. An invariant diffraction direction and phase for special moves of a diffraction grating is discussed, allowing simplification in the design of the coherently tiled grating diagnostic. An analytical proof of the existence of a unique diffraction grating eigenvector for translational and rotational motion that conserves the diffraction direction and diffracted wave phase is presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...