Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Archit Intell ; 1(1): 5, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35915820

RESUMO

Pressing problems in urban ventilation and thermal comfort affecting pedestrians related to current urban development and densification are increasingly dealt with from the perspective of climate change adaptation strategies. In recent research efforts, the prime objective is to accurately assess pedestrian-level wind (PLW) environments by using different simulation approaches that have reasonable computational time. This review aims to provide insights into the most recent PLW studies that use both established and data-driven simulation approaches during the last 5 years, covering 215 articles using computational fluid dynamics (CFD) and typical data-driven models. We observe that steady-state Reynolds-averaged Navier-Stokes (SRANS) simulations are still the most dominantly used approach. Due to the model uncertainty embedded in the SRANS approach, a sensitivity test is recommended as a remedial measure for using SRANS. Another noted thriving trend is conducting unsteady-state simulations using high-efficiency methods. Specifically, both the massively parallelized large-eddy simulation (LES) and hybrid LES-RANS offer high computational efficiency and accuracy. While data-driven models are in general believed to be more computationally efficient in predicting PLW dynamics, they in fact still call for substantial computational resources and efforts if the time for development, training and validation of a data-driven model is taken into account. The synthesized understanding of these modeling approaches is expected to facilitate the choosing of proper simulation approaches for PLW environment studies, to ultimately serving urban planning and building designs with respect to pedestrian comfort and urban ventilation assessment.

2.
Sci Total Environ ; 848: 157694, 2022 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-35907546

RESUMO

In environments with similar physical parameters, thermal comfort and sensation feelings may differ indoors and outdoors. How indoor and outdoor thermal perception differ from each other remains unclear. This study compared and discussed 29,536 field survey data, including 19,191 sets of indoor data, and 10,345 sets of outdoor data, covering five Köppen climate zones during transitional seasons and summer. Indoor data points were collected from two databases: the ASHRAE Global Thermal Comfort II and the SCATs (Smart Controls and Thermal Comfort), while outdoor data points were collected from the RUROS database (Rediscovering the Urban Realm and Open Spaces) and five individual projects executed in Singapore, Hong Kong, Guangzhou, Changsha, and Tianjin. The concepts of neutral rate (NR) and comfort rate (CR) were developed to help categorize "neutral" and "comfort" across different studies. The results of this study show that people are less sensitive to changes in thermal environment outdoors than indoors. Moreover, thermal comfort cannot be simply treated as thermal neutral, particularly for outdoor spaces. Compared with MM (mixed-mode) and NV (naturally ventilated) spaces, outdoor space does not have the highest NR, but its CR is much higher, with a wide range of SET* (Standard Effective Temperature) corresponding to CR over 80 %, from 15.5 °C to 23.4 °C. In the Cfa (humid subtropical) climate zone, significantly higher CR are recorded for outdoor spaces, although the NR are similar or even lower than those of indoors. Natural thermal resources in the outdoor thermal environment may hold the key to extending indoor comfort ranges.


Assuntos
Clima , Sensação Térmica , Hong Kong , Humanos , Aprendizagem , Estações do Ano
3.
Build Environ ; 218: 109137, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35502296

RESUMO

A COVID-19 outbreak occurred in May 2020 in a public housing building in Hong Kong - Luk Chuen House, located in Lek Yuen Estate. The horizontal cluster linked to the index case' flat (flat 812) remains to be explained. Computational fluid dynamics simulations were conducted to obtain the wind-pressure coefficients of each external opening on the eighth floor of the building. The data were then used in a multi-zone airflow model to estimate the airflow rate and aerosol concentration in the flats and corridors on that floor. Apart from flat 812 and corridors, the virus-laden aerosol concentrations in flats 811, 813, 815, 817 and 819 (opposite to flat 812, across the corridor) were the highest on the eighth floor. When the doors of flats 813 and 817 were opened by 20%, the hourly-averaged aerosol concentrations in these two flats were at least four times as high as those in flats 811, 815 and 819 during the index case's home hours or the suspected exposure period of secondary cases. Thus, the flats across the corridor that were immediately downstream from flat 812 were at the highest exposure risk under a prevailing easterly wind, especially when their doors or windows that connected to the corridor were open. Given that the floorplan and dimension of Luk Chuen House are similar to those of many hotels, our findings provide a probable explanation for COVID-19 outbreaks in quarantine hotels. Positive pressure and sufficient ventilation in the corridor would help to minimise such cross-corridor infections.

4.
J Hazard Mater ; 430: 128475, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35183827

RESUMO

Vertical transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) along a vertical column of flats has been documented in several outbreaks of coronavirus disease 2019 (COVID-19) in Guangdong and Hong Kong. We describe an outbreak in Luk Chuen House, involving two vertical columns of flats associated with an unusually connected two-stack drainage system, in which nine individuals from seven households were infected. The index case resided in Flat 812 (8th floor, Unit 12), two flats (813, 817) on its opposite side reported one case each (i.e., a horizontal sub-cluster). All other flats with infected residents were vertically associated, forming a vertical sub-cluster. We injected tracer gas (SF6) into drainage stacks via toilet or balcony of Flat 812, monitored gas concentrations in roof vent, toilet, façade, and living room in four of the seven flats with infected residents and four flats with no infected residents. The measured gas concentration distributions agreed with the observed distribution of affected flats. Aerosols leaking into drainage stacks may generate the vertical sub-cluster, whereas airflow across the corridor probably caused the horizontal sub-cluster. Sequencing and phylogenetic analyses also revealed a common point-source. The findings provided additional evidence of probable roles of drainage systems in SARS-CoV-2 transmission.


Assuntos
COVID-19 , Aerossóis , COVID-19/epidemiologia , Surtos de Doenças , Habitação , Humanos , Filogenia , SARS-CoV-2
5.
Indoor Air ; 32(1): e12952, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34747064

RESUMO

This study aims to develop a fast-response sulfur hexafluoride (SF6 ) measuring system, and evaluate its performance in tracer gas measurements for studying transient airborne contaminant transport. The new system is based on a quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor using a quantum cascade laser. Transient SF6 tracer gas measurements were carried out in an environmental chamber with an instantaneous source using both the QEPAS system and a traditional commercial instrument. Real-time SF6 concentrations, peak SF6 concentrations and average SF6 concentrations for one room time constant under two air change rates obtained by the two instruments were compared. The results show that the QEPAS system, which features a 0.4 s data acquisition interval, can provide detailed real-time SF6 concentrations even when the concentration is changing rapidly. The QEPAS system successfully captured the peak SF6 concentrations for all the studies cases, while commercial instrument failed in most studied cases. In most of the cases, the two instruments obtained similar average SF6 concentrations for one room time constant. However, when the concentration was in rapid change, the two systems would report significantly different results. The QEPAS system can be potentially applied in transient tracer gas measurements under complex scenarios.


Assuntos
Poluição do Ar em Ambientes Fechados , Quartzo , Poluição do Ar em Ambientes Fechados/análise , Análise Espectral/métodos , Hexafluoreto de Enxofre/análise , Hexafluoreto de Enxofre/química
6.
Sci Total Environ ; 771: 144910, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33736141

RESUMO

Thermal comfort research has been historically centred around the concept of "thermal neutrality". Thermal neutrality originates from the steady-state indoor environment and is increasingly questioned when used to define the optimum sensation in outdoor environments. This calls for new criteria, designated for non-steady state and dynamically evolving outdoor settings. To address this need, we investigated thermal pleasure dynamics in outdoor environments based on thermal alliesthesia - a psychophysiological framework for understanding the hedonic responses elicited by non-steady-state thermal exposures. Detailed field studies were conducted in Sydney, Australia, during a 30-day period covering both summer and winter with a total of 35 subjects. The thermal sensation scale was quantitatively divided into four alliesthesial potential areas - two with moderate and two with strong alliesthesial potential - based on their divergence to the preferred sensation. We find that the temporal pleasure change (dP) can be predicted using thermal sensation change (dT). The results showed that linear regression performed strongly (R2 = 0.77 for summer and R2 = 0.79 for winter) in predicting dP when subjects' preceding sensation was in the strong alliesthesial potential zones - namely the 'Hot' and 'Cold' areas. When subjects' prior thermal sensation fell in the thermoneutral zone with moderate alliesthesial potential, a quadratic fit against dT provides a more reasonable prediction of dP (R2 = 0.61 for summer and R2 = 0.56 for winter). The dynamic thermal pleasure models provide a more nuanced subjective interpretation of outdoor urban spaces that includes thermal pleasure and delight. This study contributes further empirical support to the thermal alliesthesia framework and extends its application scope into outdoor thermal comfort research.


Assuntos
Interocepção , Austrália , Humanos , Prazer , Estações do Ano , Temperatura , Sensação Térmica
7.
Materials (Basel) ; 15(1)2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35009265

RESUMO

Thermal energy storage (TES) is an important means for the conservation and efficient utilization of excessive and renewable energy. With a much higher thermal storage capacity, latent heat storage (LHS) may be more efficient than sensible heat storage. Phase change materials (PCMs) are the essential storage media for LHS. PCM emulsions have been developed for LHS in flow systems, which act as both heat transfer and thermal storage media with enhanced heat transfer, low pumping power, and high thermal storage capacity. However, two major barriers to the application of PCM emulsions are their instability and high degree of supercooling. To overcome these, various strategies have been attempted, such as the reduction of emulsion droplet size, addition of nucleating agents, and optimization of the formulation. To the best of our knowledge, however, there is still a lack of review articles on fabrication methods for PCM emulsions or their latest applications. This review was to provide an up-to-date and comprehensive summary on the effective strategies and the underlying mechanisms for the preparation of stable PCM emulsions and reduction of supercooling, especially with the organic PCMs of paraffin. It was also to share our insightful perspectives on further development and potential applications of PCM emulsions for efficient energy storage.

9.
Build Simul ; 11(1): 193-202, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-32218902

RESUMO

Identifying possible airborne transmission routes and assessing the associated infectious risks are essential for implementing effective control measures. This study focuses on the infiltration-induced inter-unit pollutant dispersion in a high-rise residential (HRR) building. The outdoor wind pressure distribution on the building facades was obtained from the wind tunnel experiments. And the inter-household infiltration and tracer gas transmission were simulated using multi-zone model. The risk levels along building height and under different wind directions were examined, and influence of component leakage area was analysed. It is found that, the cross-infection risk can be over 20% because of the low air infiltration rate below 0.7 ACH, which is significantly higher than the risk of 9% obtained in our previous on-site measurement with air change rate over 3 ACH. As the air infiltration rate increases along building height, cross-infection risk is generally higher on the lower floors. The effect of wind direction on inter-unit dispersion level is significant, and the presence of a contaminant source in the windward side results in the highest cross-infection risks in other adjacent units on the same floor. Properly improving internal components tightness and increasing air change via external components are beneficial to the control of internal inter-unit transmission induced by infiltration. However, this approach may increase the cross-infection via the external transmission, and effective control measures should be further explored considering multiple transmission routes.

10.
Build Environ ; 124: 245-257, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32287974

RESUMO

Owing to the void space at lower heights, lift-up buildings have high building permeability at ground level and subsequently improve the air circulation in congested urban areas. Despite this advantage, the lift-up design has been sparsely adopted for buildings in urban areas partly because of the lack of understanding of the combined effects of building dimensions and lift-up design on the surrounding pedestrian level wind (PLW) field. Therefore, this study aims to investigate the influence of lift-up buildings with different aspect ratios (height/width) on the surrounding PLW field and pedestrian wind comfort level. Five lift-up buildings with aspect ratios 4:1 to 0.5:1 were tested in a boundary layer wind tunnel and results were compared with those of five buildings with similar dimensions but without lift-up design. The results reveal a strong dependence of the maximum wind speed in lift-up areas with building height, which results subsequently a small area of acceptable wind conditions near tall and slender lift-up buildings. Lift-up designs adopted for short and wide buildings produce larger areas of pedestrian wind comfort. The central cores modified with corner modifications are effective in increasing the pedestrian wind comfort in the lift-up area of tall and slender buildings.

11.
Build Environ ; 117: 154-165, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32362712

RESUMO

Modern megacities are teeming with closely-spaced tall buildings, which limit air circulation at the pedestrian level. The resultant lack of air circulation creates poorly ventilated areas with accumulated air pollutants and thermal discomfort in the summer. To improve air circulation at the pedestrian level, buildings may be designed to have a 'lift-up' shape, in which the main structure is supported by a central core, columns or shear walls. However, a lack of knowledge on the influence of the 'lift-up' design on the surrounding wind environment limits the use of 'lift-up' buildings. This study aims to investigate the influence of 'lift-up' buildings and their dimensions on the pedestrian-level wind environments using wind tunnel tests. A parametric study was undertaken by using 9 'lift-up' building models with different core heights and widths. The results were compared with the surrounding wind environment of a control building with similar dimensions. The results reveal that the 'lift-up' core height is the most influential parameter and governs the area and magnitude of high and low wind speed zones around such buildings. Based on wind tunnel test results and a selected comfort criterion, appropriate core dimensions could be selected to have acceptable wind conditions near lift-up buildings.

12.
Build Environ ; 99: 13-21, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32288039

RESUMO

Airborne transmission is a main spread mode of respiratory infectious diseases, whose frequent epidemic has brought serious social burden. Identifying possible routes of the airborne transmission and predicting the potential infection risk are meaningful for infectious disease control. In the present study, an internal spread route between horizontal adjacent flats induced by air infiltration was investigated. On-site measurements were conducted, and tracer gas technique was employed. Two measurement scenarios, closed window mode and open window mode, were compared. Using the calculated air change rate and mass fraction, the cross-infection risk was estimated using the Wells-Riley model. It found that tracer gas concentrations in receptor rooms are one order lower than the source room, and the infection risks are also one order lower. Opening windows results in larger air change rate on the one hand, but higher mass fraction on the other hand. Higher mass fraction not necessarily results in higher infection risk as the pathogen concentration in the source room is reduced by the higher air change rate. In the present study, opening windows could significantly reduce the infection risk of the index room but slightly reduce the risks in receptor rooms. The mass fraction of air originated from the index room to the receptor units could be 0.28 and the relative cross-infection risk through the internal transmission route could be 9%, which are higher than the external spread through single-sided window flush. The study implicates that the horizontal transmission route induced by air infiltration should not be underestimated.

13.
J Cent South Univ ; 19(3): 645-650, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-32288947

RESUMO

Existed evidences show that airborne transmission of human respiratory droplets may be related with the spread of some infectious disease, such as severe acute respiratory syndrome (SARS) and H1N1 pandemic. Non-pharmaceutical approaches, including ventilation system and personal protection, are believed to have certain positive effects on the reduction of co-occupant's inhalation. This work then aims to numerically study the performances of mouth covering on co-occupant's exposure under mixing ventilation (MV), under-floor air distribution (UFAD) and displacement ventilation (DV) system, using drift-flux model. Desk partition, as one generally employed arrangement in plan office, is also investigated under MV. The dispersion of 1, 5 and 10 µm droplet residuals are numerically calculated and CO2 is used to represent tracer gas. The results show that using mouth covering by the infected person can reduce the co-occupant's inhalation greatly by interrupting direct spread of the expelled droplets, and best performance can be achieved under DV since the coughed air is mainly confined in the microenvironment of the infected person. The researches under MV show that the two interventions, mouth covering and desk partition, achieve almost the same inhalation for fine droplets while the inhalation of the co-occupant is lower when using mouth covering for large droplets.

14.
Build Environ ; 46(2): 397-408, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32288015

RESUMO

This paper investigated the transmission of respiratory droplets between two seated occupants equipped with one type of personalized ventilation (PV) device using round movable panel (RMP) in an office room. The office was ventilated by three different total volume (TV) ventilation strategies, i.e. mixing ventilation (MV), displacement ventilation (DV), and under-floor air distribution (UFAD) system respectively as background ventilation methods. Concentrations of particles with aerodynamic diameters of 0.8 µm, 5 µm, and 16 µm as well as tracer gas were numerically studied in the Eulerian frame. Two indexes, i.e. intake fraction (IF) and concentration uniformity index R C were introduced to evaluate the performance of ventilation systems. It was found that without PV, DV performed best concern protecting the exposed manikin from the pollutants exhaled by the polluting manikin. In MV when the exposed manikin opened RMP the inhaled air quality could always be improved. In DV and UFAD application of RMP might sometimes, depending on the personalized airflow rate, increase the exposure of the others to the exhaled droplets of tracer gas, 0.8 µm particles, and 5 µm particles from the infected occupants. Application of PV could reduce R C for all the three TV systems of 0.8 µm and 5 µm particles. PV enhanced mixing degree of particles under DV and UFAD based conditions much stronger than under MV based ones. PV could increase the average concentration in the occupied zone of the exposed manikin as well as provide clean personalized airflow. Whether inhaled air quality could be improved depended on the balance of pros and cons of PV.

15.
Build Environ ; 41(9): 1214-1222, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32287998

RESUMO

It is known that the person-to-person spreading of certain infectious diseases is related with the transmission of human exhaled air in the indoor environments, and this is suspected to be the case with the severe acute respiratory syndrome (SARS) outbreak. This paper presents the numerical analysis of the human respiration process and the transport of exhaled air by breathing, sneezing, and coughing and their potential impact on the adjacent person in a modeled room with displacement ventilation. In order to account for the influence of the thermal plume around the human body, a three-dimensional computational thermal manikin (CTM) with an accurate description of body geometry was applied. Some of the results were compared with those from former simulations and experiments. It was found that personal exposure to the exhaled air from the normal respiration process of other persons is very low in a modeled room with displacement ventilation. Personal exposure to pollution caused by sneezing or coughing is highly directional. When two occupants face each other the cross-infection may happen due to the long transport distance of the exhalation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...