Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Microbiology (Reading) ; 168(3)2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35275049

RESUMO

Globally, healthcare-associated infections (HAI) are the most frequent adverse outcome in healthcare delivery. Although bacterial biofilms contribute significantly to the incidence of HAI, few studies have investigated the efficacy of common disinfectants against dry-surface biofilms (DSB). The objective of this study was to evaluate the bactericidal efficacy of seven Environmental Protection Agency (EPA)-registered liquid disinfectants against DSB of Staphylococcus aureus and Pseudomonas aeruginosa. We hypothesized that overall, there will be significant differences among the bactericidal efficacies of tested disinfectants by product type and active ingredient class. We also hypothesized that depending on the species, higher bactericidal efficacies against DSB will be exhibited after 24 h of dehydration compared to 72 h. Wet-surface biofilms of S. aureus and P. aeruginosa were grown following EPA-MLB-SOP-MB-19 and dehydrated for 24 and 72 h to establish DSB. Seven EPA-registered disinfectants were tested against dehydrated DSB following EPA-MLB-SOP-MB-20. Overall, quaternary ammonium plus alcohol, sodium dichloro-s-triazinetrione and hydrogen peroxide products were more efficacious against DSB than quaternary ammoniums for both tested species. While there was no significant difference in the log10 reductions between 24 and 72 h S. aureus biofilms, significantly higher log10 reductions were observed when products were challenged with 24 h P. aeruginosa DSB compared to 72 h P. aeruginosa DSB. Species type, active ingredient class and dry time significantly impact disinfectant efficacy against DSB of S. aureus or P. aeruginosa.


Assuntos
Compostos de Amônio , Desinfetantes , Álcoois , Biofilmes , Desinfetantes/farmacologia , Peróxido de Hidrogênio/farmacologia , Pseudomonas aeruginosa , Sódio , Staphylococcus aureus
2.
Antimicrob Resist Infect Control ; 9(1): 176, 2020 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-33148316

RESUMO

BACKGROUND: Pre-wetted disinfectant wipes are increasingly being used in healthcare facilities to help address the risk of healthcare associated infections (HAIs). However, HAIs are still a major problem in the US with Clostridioides difficile being the most common cause, leading to approximately 12,800 deaths annually in the US. An underexplored risk when using disinfectant wipes is that they may cross-contaminate uncontaminated surfaces during the wiping process. The objective of this study was to determine the cross-contamination risk that pre-wetted disinfectant towelettes may pose when challenged with C. difficile spores. We hypothesized that although the tested disinfectant wipes had no sporicidal claims, they will reduce spore loads. We also hypothesized that hydrogen peroxide disinfectant towelettes would present a lower cross-contamination risk than quaternary ammonium products. METHODS: We evaluated the risk of cross-contamination when disinfectant wipes are challenged with C. difficile ATCC 43598 spores on Formica surfaces. A disinfectant wipe was used to wipe a Formica sheet inoculated with C. difficile. After the wiping process, we determined log10 CFU on previously uncontaminated pre-determined distances from the inoculation point and on the used wipes. RESULTS: We found that the disinfectant wipes transferred C. difficile spores from inoculated surfaces to previously uncontaminated surfaces. We also found that wipes physically removed C. difficile spores and that hydrogen peroxide disinfectants were more sporicidal than the quaternary ammonium disinfectants. CONCLUSION: Regardless of the product type, all disinfectant wipes had some sporicidal effect but transferred C. difficile spores from contaminated to otherwise previously uncontaminated surfaces. Disinfectant wipes retain C. difficile spores during and after the wiping process.


Assuntos
Clostridioides difficile/efeitos dos fármacos , Desinfetantes/farmacologia , Desinfecção/métodos , Esporos Bacterianos/efeitos dos fármacos , Peróxido de Hidrogênio/farmacologia
3.
Antimicrob Resist Infect Control ; 9(1): 134, 2020 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-32807240

RESUMO

BACKGROUND: Bacterial biofilms persistent on dry environmental surfaces in healthcare facilities play an important role in the occurrence of healthcare associated infections (HAI). Compared to wet surface biofilms and planktonic bacteria, dry surface biofilms (DSB) are more tolerant to disinfection. However, there is no official method for developing DSB for in vitro disinfectant efficacy testing. The objectives of this study were to (i) develop an in vitro model of DSB of S. aureus and P. aeruginosa for disinfectant efficacy testing and (ii) investigate the effect of drying times and temperatures on DSB development. We hypothesized that a minimum six log10 density of DSB could be achieved on glass coupons by desiccating wet surface biofilms near room temperatures. We also hypothesized that a DSB produced by the model in this study will be encased in extracellular polymeric substances (EPS). METHODS: S. aureus ATCC-6538 and P. aeruginosa ATCC-15442 wet surface biofilms were grown on glass coupons following EPA MLB SOP MB-19. A DSB model was developed by drying coupons in an incubator and viable bacteria were recovered following a modified version of EPA MLB SOP MB-20. Scanning electron microscopy was used to confirm the EPS presence on DSB. RESULTS: Overall, a minimum of six mean log10 densities of DSB for disinfectant efficacy were recovered per coupon after drying at different temperatures and drying times. Regardless of strain, temperature and dry time, 86% of coupons with DSB were confirmed to have EPS. CONCLUSION: A rapid model for developing DSB with characteristic EPS was developed for disinfectant efficacy testing against DSB.


Assuntos
Biofilmes/efeitos dos fármacos , Desinfetantes/farmacologia , Desinfecção/métodos , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Pseudomonas aeruginosa/fisiologia , Staphylococcus aureus/fisiologia , Propriedades de Superfície
4.
Antimicrob Resist Infect Control ; 9(1): 141, 2020 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-32831143

RESUMO

BACKGROUND: Disinfectant products are used frequently on environmental surfaces (e.g. medical equipment, countertops, patient beds) and patient care equipment within healthcare facilities. The purpose of this study was to assess the risk of cross-contamination of Staphylococcus aureus and Pseudomonas aeruginosa during and after disinfection of predetermined surface areas with ready-to-use (RTU) pre-wetted disinfectant towelettes. METHODS: This study tested six disinfectant towelette products against S. aureus ATCC CRM-6538 and P. aeruginosa strain ATCC-15442 on Formica surfaces. Each disinfectant was evaluated on a hard nonporous surface and efficacy was measured every 0.5 m2 using a modified version of EPA MLB SOP-MB-33 to study the risk of cross-contamination. RESULTS: We found that all of the wipes used in this study transferred S. aureus and P. aeruginosa from an inoculated surface to previously uncontaminated surfaces. Disinfectant towelettes with certain chemistries also retained a high level of viable bacteria after disinfection of the surface area. The cross-contamination risk also varied by product chemistry and bacterial strain. CONCLUSION: Disinfectant wipes can cross-contaminate hard nonporous surfaces and retain viable bacterial cells post-disinfection, especially over larger surface areas. This highlights a need to further investigate the risk disinfectant wipes pose during and post-disinfection and guidance on maximum surface areas treated with a single towelette.


Assuntos
Desinfetantes/análise , Fômites/microbiologia , Pseudomonas aeruginosa/crescimento & desenvolvimento , Staphylococcus aureus/crescimento & desenvolvimento , Desinfecção/instrumentação , Microbiologia Ambiental , Contaminação de Equipamentos , Humanos , Viabilidade Microbiana
5.
Artigo em Inglês | MEDLINE | ID: mdl-30568790

RESUMO

Background: Antimicrobial disinfectants are used as primary treatment options against pathogens on surfaces in healthcare facilities to help prevent healthcare associated infections (HAIs). On many surfaces, pathogenic microorganisms exist as biofilms and form an extracellular matrix that protects them from the antimicrobial effects of disinfectants. Disinfectants are used as all-purpose antimicrobials though very few specifically make biofilm efficacy claims. The objective of this study was to evaluate the efficacy of eight registered disinfectants (six registered by the Environmental Protection Agency and two products registered in by the European Chemical Agency) with general bactericidal claims, but currently no biofilm efficacy claims, against Staphylococcus aureus ATTC-6538 and Pseudomonas aeruginosa ATCC-15442 biofilms. We hypothesized that hydrogen peroxide and sodium hypochlorite disinfectant products would be more effective than quaternary ammonium chlorides. Methods: This study tested the bactericidal efficacy of eight registered disinfectant products against S. aureus ATCC-6538 and P. aeruginosa ATCC-15442 grown on glass coupons using a Center for Disease Control (CDC) biofilm reactor and EPA MLB SOP MB-19. Bactericidal efficacy was determined after treating coupons with disinfectants following standard EPA MLB SOP MB-20. Results: Overall, sodium hypochlorite and hydrogen peroxide disinfectants had significantly higher bactericidal efficacies than quaternary ammonium chloride disinfectants. We also found that all tested disinfectants except for quaternary ammonium chloride disinfectants met and exceeded the EPA standard for bactericidal efficacy against biofilms. Conclusion: In general, bactericidal efficacy against biofilms differed by active ingredient. The efficacies of sodium hypochlorite and hydrogen peroxide disinfectants did not vary between strains, but there were significant differences between strains treated with quaternary ammonium chloride disinfectants.


Assuntos
Biofilmes/efeitos dos fármacos , Desinfetantes/farmacologia , Peróxido de Hidrogênio/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Compostos de Amônio Quaternário/farmacologia , Hipoclorito de Sódio/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Antibacterianos/farmacologia , Biofilmes/crescimento & desenvolvimento , Infecção Hospitalar/prevenção & controle , Combinação de Medicamentos , Sinergismo Farmacológico , Propriedades de Superfície/efeitos dos fármacos
6.
Artigo em Inglês | MEDLINE | ID: mdl-30338060

RESUMO

Background: Disinfectant products are often used on environmental surfaces (e.g. countertops, patient beds) and patient care equipment in healthcare facilities to help prevent the transmission of healthcare-associated infections. Ready-to-use (RTU) disinfectants in the form of pre-wetted towelettes are increasingly popular among healthcare facilities. Currently, the EPA does not require disinfectant manufacturers to include a recommended maximum surface area per towelette on their product labels. The objective of this study was to investigate the efficacy of disinfectant towelette products on a hard non-porous surface across different coverage areas using a quantitative EPA method. We hypothesized that there would be significant differences in the efficacy of disinfectant towelette products, and that the greater surface area(s) wiped would result in reduced bactericidal efficacy. Methods: This study tested ten disinfectant towelette products against Staphylococcus aureus strain ATCC CRM-6538 and Pseudomonas aeruginosa strain ATCC 15442 on Formica surfaces. Defined surface areas were wiped and the towelette weighed before and after wiping to determine the amount of liquid released. Bactericidal efficacy testing was also performed after wiping following standard EPA protocols. Results: We found that disinfectant product, area of surface wiped, and strain impacted the bactericidal efficacy achieved. Disinfectant product type and area of surface wiped significantly impacted the percent of liquid released per ft2from the towelette. Conclusion: Overall, bactericidal efficacy varied by towelette product, surface area wiped, and strain. This study also found that wiping larger surface areas may lead to decreased bactericidal efficacy. Further research is needed to test its implication.


Assuntos
Antibacterianos/farmacologia , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Desinfetantes/farmacologia , Desinfecção , Desinfecção/instrumentação , Desinfecção/métodos , Humanos , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Esterilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...