Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gen Comp Endocrinol ; 212: 73-83, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25616196

RESUMO

The effect of long-term stress on amphibian immunity is not well understood. We modeled a long-term endocrine stress scenario by elevating plasma corticosterone in two species of amphibians and examined effects on white blood cell differentials and innate immune activity. Plasma corticosterone was elevated in American bullfrogs (Lithobates catesbeianus) by surgically implanting corticosterone capsules and in African clawed frogs (Xenopus laevis) by immersion in corticosterone-treated water. To provide a context for our results within endogenous corticosterone fluctuations, diurnal plasma corticosterone cycles were determined. A daily low of corticosterone was observed in X. laevis at 12:00, while a significant pattern was not observed in L. catesbeianus. Elevated plasma corticosterone levels increased the ratio of peripheral neutrophils to lymphocytes, in both species, and decreased eosinophil concentrations in L. catesbeianus over a long-term period. Whole blood oxidative burst generally correlated with neutrophil concentrations, and thus was increased with corticosterone treatment, significantly in L. catesbeianus. In L. catesbeianus, an endogenous response of eosinophils and lymphocytes to implanted empty (sham) capsules was observed, but this effect was attenuated by corticosterone. Peripheral monocyte and basophil concentrations were not significantly altered by corticosterone treatment in either species. Our results show that long-term stress can alter amphibian immune parameters for extended periods and may play a role in susceptibility to disease.


Assuntos
Anti-Inflamatórios/farmacologia , Corticosterona/farmacologia , Sistema Endócrino/efeitos dos fármacos , Rana catesbeiana/fisiologia , Xenopus laevis/fisiologia , Animais , Anti-Inflamatórios/sangue , Células Cultivadas , Corticosterona/sangue , Eosinófilos/efeitos dos fármacos , Eosinófilos/metabolismo , Imunoensaio , Leucócitos/efeitos dos fármacos , Leucócitos/metabolismo , Linfócitos/efeitos dos fármacos , Linfócitos/metabolismo , Monócitos/efeitos dos fármacos , Monócitos/metabolismo , Neutrófilos/efeitos dos fármacos , Neutrófilos/metabolismo
2.
J Air Waste Manag Assoc ; 57(1): 14-30, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17269226

RESUMO

Subsequent to the 1997 promulgation of the Federal Reference Method (FRM) for monitoring fine particulate matter (PM2.5) in ambient air, U.S. Environmental Protection Agency (EPA) received reports that the DOW 704 diffusion oil used in the method's Well Impactor Ninety-Six (WINS) fractionator would occasionally crystallize during field use, particularly under wintertime conditions. Although the frequency of occurrence on a nationwide basis was low, uncertainties existed as to whether crystallization of the DOW 704 oil may adversely affect a sampling event's data quality. In response to these concerns, EPA and the State of Connecticut Department of Environmental Protection jointly conducted a series of specialized tests to determine whether crystallized oil adversely affected the performance of the WINS fractionator. In the laboratory, an experimental setup used dry ice to artificially induce crystallization of the diffusion oil under controlled conditions. Using primary polystyrene latex calibration aerosols, standard size-selective performance tests of the WINS fractionator showed that neither the position nor the shape of the WINS particle size fractionation curve was substantially influenced by the crystallization of the DOW 704 oil. No large particle bounce from the crystallized impaction surface was observed. During wintertime field tests, crystallization of the DOW 704 oil did not adversely affect measured PM2.5 concentrations. Regression of measurements with crystallized DOW 704 versus liquid dioctyl sebacate (DOS) oil produced slope, intercept, and R2 values of 0.98, 0.1, and 0.997 microg/m3, respectively. Additional field tests validated the use of DOS as an effective impaction substrate. As a result of these laboratory and field tests, DOS oil has been approved by EPA as a substitute for DOW 704 oil. Since the field deployment of DOS oil in 2001, users of this alternative oil have not reported any operational problems associated with its use in the PM2.5 FRM. Limited field evaluation of the BGI very sharp cut cyclone indicates that it provides a viable alternative to the WINS fractionator.


Assuntos
Poluição do Ar/análise , Monitoramento Ambiental/instrumentação , Óleos/química , Calibragem , Cristalização , Tamanho da Partícula , Reprodutibilidade dos Testes , Temperatura
3.
Environ Sci Technol ; 38(8): 2317-27, 2004 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15116836

RESUMO

The relationship between continuous measurements of volatile organic compounds sources and particle number was evaluated at a Photochemical Assessment Monitoring Station Network (PAMS) site located near the U.S.-Mexico Border in central El Paso, TX. Sources of volatile organic compounds (VOCs) were investigated using the multivariate receptor model UNMIX and the effective variance least squares receptor model known as Chemical Mass Balance (CMB, Version 8.0). As expected from PAMS measurements, overall findings from data screening as well as both receptor models confirmed that mobile sources were the major source of VOCs. Comparison of hourly source contribution estimates (SCEs) from the two receptor models revealed significant differences in motor vehicle exhaust and evaporative gasoline contributions. However, the motor vehicle exhaust contributions were highly correlated with each other. Motor vehicle exhaust was also correlated with the ultrafine and accumulation mode particle count, which suggests that motor vehicle exhaust is a source of these particles at the measurement site. Wind sector analyses were performed using the SCE and pollutant data to assess source location of VOCs, particle count, and criteria pollutants. Results from this study have application to source apportionment studies and mobile source emission control strategies that are ongoing in this air shed.


Assuntos
Poluentes Atmosféricos/análise , Modelos Teóricos , Emissões de Veículos/análise , Vento , Cidades , Clima Desértico , Análise Multivariada , Compostos Orgânicos/análise , Tamanho da Partícula , Volatilização
4.
J Air Waste Manag Assoc ; 54(3): 307-19, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15068008

RESUMO

This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks. OVM concentrations were corrected for ambient pressure to account for higher elevation. Precise results (< 5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs (> or = 77% RSD for 2-day samples) with better precision for longer sampling periods. Comparison of Ogawa NO2 samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer. For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements. The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs. However, except for toluene, OVM BTEX measurements generally exceeded their continuous counterparts with a mean bias of 5-10%. Although interpretation of the study results was limited due to small sample sizes, diffusion barrier influences caused by shelters that housed OVMs and differences in sampling heights between OVMs and auto-GC inlet may explain the overestimation.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Modelos Estatísticos , Dióxido de Nitrogênio/análise , Automação , Medições Luminescentes , Compostos Orgânicos/análise , Sensibilidade e Especificidade , Texas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...