Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 63(6): 653-60, 2007 Jun 20.
Artigo em Japonês | MEDLINE | ID: mdl-17625356

RESUMO

Negative product value for coronary artery disease is 98% to 99%. Therefore, the number of unnecessary cardiac catheterization procedures is reduced as the usefulness of CT systems for examination of the coronary arteries improves. In the bolus-tracking method, in which an ROI is placed in the ascending aorta to trigger scanning, scanning may not be performed at the optimal time of contrast enhancement depending on the patient. In addition to identifying the causes of this problem, we have developed a new method in which ROIs are placed in the right ventricle and left atrium to trigger scanning when the concentrations of contrast medium in the right ventricle and left atrium become equal. The two methods were then compared and evaluated. In the scan method, in which an ROI is placed in the ascending aorta, the reason for non-optimal scan timing is considered to be that the time required for contrast medium injected via an antecubital vein to reach the heart varies depending on the individual patient(approximately 3 times the variation of our method)followed by a delay of approximately 5 seconds between the scan trigger time and the actual scan start time. In the scan method in which scanning is triggered when the concentrations of contrast medium in the right ventricle and left atrium become equal, scanning can be performed at the time of peak enhancement regardless of differences in the time required for the injected contrast medium to reach the target region or differences in the injection rate, demonstrating the usefulness of this method.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta , Peso Corporal , Débito Cardíaco , Meios de Contraste/farmacocinética , Feminino , Átrios do Coração/metabolismo , Ventrículos do Coração/metabolismo , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 61(2): 277-84, 2005 Feb 20.
Artigo em Japonês | MEDLINE | ID: mdl-15753869

RESUMO

To investigate the clinical usefulness of coronary arteriography using a gadolinium contrast medium (hereinafter referred to as Gd contrast medium) in patients with iodine allergy, images obtained using an iodinated contrast medium and a Gd contrast medium were compared using respective phantoms. Within the range of the effective energy (34.8 to 41.0 keV) in clinical use, the tube-voltage dependency of the Gd contrast medium was lower than that of the iodinated contrast medium. The contrast ratios were found to be comparable for the images obtained by a 4-fold-diluted iodinated contrast medium and the undiluted Gd contrast medium. Although the assessment of stenotic ratio was difficult to obtain by visual evaluation of the clinical images, due to unclear borders of the blood vessels, the presence or absence of significant stenosis was discriminative by arteriography using the Gd contrast medium. Based on these findings, it was considered necessary to make a confirmed diagnosis using a Gd contrast medium with concurrent diagnosis by intravascular echography. In conclusion, coronary arteriography and PCI using a Gd contrast medium are considered to offer benefit to the diagnosis and treatment of patients with iodine allergy.


Assuntos
Meios de Contraste , Angiografia Coronária/métodos , Gadolínio , Angioplastia Coronária com Balão/métodos , Meios de Contraste/efeitos adversos , Hipersensibilidade a Drogas/etiologia , Humanos , Iodo/efeitos adversos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...