Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 18: 1871-1878, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38948344

RESUMO

Purpose: To compare outcomes of ab-interno canaloplasty and trabeculotomy of the superior versus inferior angle. Patients and methods: This was a prospective, non-randomized, interventional comparison study done at the Veteran Affairs Hospital in Long Beach, California. All patients underwent cataract surgery with intraocular lens implantation combined with ab-interno canaloplasty and trabeculotomy with the OMNI Surgical System (SightSciences, Menlo Park, CA, USA), either superiorly or inferiorly. Pre- and post-operative intraocular pressure using Goldmann applanation tonometry and best corrected visual acuity were obtained and compared using paired t-tests. Patients were excluded if they had any prior intraocular surgery or prior laser trabeculoplasty procedures. Results: 38 eyes from 29 patients were analyzed. 19 eyes were included in the superior group and 19 eyes in the inferior group. Mean pre-operative IOP in the superior group was 17.6 ± 5.2 mmHg and in the inferior group was 17.6 ± 4.6 mmHg (p > 0.99). At 12 months, mean postoperative IOP for the superior group decreased 24% to 13.3 ± 2.8 mmHg while the inferior group decreased 26% to 13.1 ± 2.2 mmHg (p = 0.92). Mean preoperative medications in the superior group were 2.2 ± 1.3 and in the inferior group was 2.4 ± 1.3 (p = 0.88). At 12 months, this decreased to 1.3 ± 1.5 post-operatively in the superior group and 2.2 ± 1.6 post-operatively in the inferior group (p = 0.64). Conclusion: There was no statistical difference in efficacy between superior versus inferior canaloplasty/trabeculotomy with OMNI. Therefore, surgeons can perform the procedure in the direction that is most comfortable for them without affecting outcomes.

2.
Clin Ophthalmol ; 18: 17-26, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38192581

RESUMO

Purpose: To evaluate outcomes of new adopters of the OMNI® Surgical System (Sight Sciences, Inc.) by prospectively evaluating intermediate-term outcomes of patients operated by trainees. Patients and Methods: This was a prospective study of surgeries performed by trainees on patients with open angle glaucoma undergoing simultaneous cataract surgery and ab interno canaloplasty and trabeculotomy using the OMNI Surgical System. Pre-operative intraocular pressure (IOP) and number of glaucoma medications were recorded. Only patients with a minimum of 6-month follow up were included. Baseline IOP was used to separate subjects into two groups: Group 1 (IOP ≥18 mmHg) and Group 2 (IOP <18 mmHg). Mean decrease in IOP and medications was calculated and compared with paired t-tests for the overall sample as well as the subgroups. Success was defined as those with a ≥20% reduction from pre-operative IOP or with an IOP ≤18 mmHg and ≥6 mmHg and on the same or fewer number of medications while not requiring additional surgery. Adverse events were also recorded. Results: Forty-two eyes of 31 patients were included. Mean pre-operative IOP was 17.2 ± 4.8 mmHg and mean number of medications was 2.4 ± 1.2. The primary endpoint was reached in 83.3% of patients at 12 months. IOP was reduced by 22.3% to 13.4 ± 2.4 (p<0.001). Mean number of medications decreased to 1.7 ± 1.6 (p<0.001). Group 1 mean IOP decreased 35.4% from 22.2 ± 4.6 mmHg to 14.3 ± 2.8 mmHg (p<0.001). Group 2 mean number of medications decreased from 2.3 ± 1.1 to 1.6 ± 1.5 (p<0.001). Conclusion: When operated on by the novice MIGS surgeon, the OMNI device provides effective IOP and glaucoma medication reduction with minimal adverse events. Efficacy and safety of the device in the hands of trainees was comparable to experienced glaucoma surgeons suggesting its ease of adoption.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...