J Appl Clin Med Phys ; 23(2): e13480, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34837723

RESUMO

PURPOSE: The purpose of this study was to investigate the matching error that occurs when the Mobius3D fingerprinting system is applied in conjunction with an Elekta linear accelerator (LINAC) and to offer an acceptable and alternative method for circumventing this problem. MATERIAL AND METHODS: To avoid the multileaf collimator (MLC) conflicting error in the Mobius3D fingerprinting system, we developed an in-house program to move the MLC in the Digital Imaging and Communications in Medicine (DICOM) radiotherapy (RT)-Plan to pertinent positions, considering the relationship between log data and planned data. The re-delivered log files were calculated in the Mobius3D system, and the results were compared with those of corrected data (i.e., we analyzed a pair of re-collected log data and the previous DICOM RT-Plan data). The results were then evaluated by comparing several items, such as point dose errors, gamma index (GI) passing rates, and MLC root-mean-square (RMS) values. RESULTS: For the point dose error, the maximum difference found was below 2.0%. In the case of GI analysis of all plans, the maximum difference in the passing rates was below 1.4%. The statistical results obtained using a paired Student's t-test showed that there were no significant differences within the uncertainty. In the case of the RMS test, the maximum difference found was approximately 0.08 mm. CONCLUSIONS: Our results showed that all the mismatched log files were sufficiently acceptable within the uncertainty. We conclude that the matching error obtained when applying Mobius3D to an Elekta LINAC may be addressed using a simple modification of the fingerprinting system, and we expect that our study findings will help vendors resolve this issue in the near future.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Raios gama , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica
2.
PLoS One ; 15(12): e0234829, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33270667

RESUMO

BACKGROUND: This study investigated the effect of accumulated doses on radio-photoluminescence glass dosimeters (RPLGDs) from measurements involving mega-voltage photons. METHODS: Forty-five commercially available RPLGDs were irradiated to estimate their dose responses. Photon beams of 6, 10, and 15 MV were irradiated onto the RPLGDs inside a phantom, which were divided into five groups with different doses and energies. Groups 1 and 2 were irradiated at 1, 5, 10, 50, and 100 Gy in a sequential manner; Group 3 was irradiated 10 times with a dose of 10 Gy; and Groups 4 and 5 followed the same method as that of Group 3, but with doses of 50 Gy and 100 Gy, respectively. Each device was subjected to a measurement reading procedure each time irradiation. RESULTS: For the annealed Group 1, RPLGD exhibited a linearity response with variance within 5%. For the non-annealed Group 2, readings demonstrated hyperlinearity at 6 MV and 10 MV, and linearity at 15 MV. Following the 100 Gy irradiation, the readings for Group 2 were 118.7 ± 1.9%, 112.2 ± 2.7%, and 101.5 ± 2.3% at 6, 10, and 15 MV, respectively. For Groups 3, 4, and 5, the responsiveness of the RPLGDs gradually decreased as the number of repeated irradiations increased. The percentage readings for the 10th beam irradiation with respect to the readings for the primary beam irradiation were 84.6 ± 1.9%, 87.5 ± 2.4%, and 93.0 ± 3.0% at 6 MV, 10 MV, and 15 MV, respectively. CONCLUSIONS: The non-annealed RPLGD response to dose was hyperlinear for the 6 MV and 10 MV photon beams but not for the 15 MV photon beam. Additionally, the annealed RPLGD exhibited a fading phenomenon when the measurement was repeated several times and demonstrated a relatively large fading effect at low energies than at high energies.


Assuntos
Dosímetros de Radiação , Vidro , Imagens de Fantasmas , Fótons , Doses de Radiação , Dosagem Radioterapêutica , Sensibilidade e Especificidade
3.
Phys Eng Sci Med ; 43(3): 1069-1075, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32700205

RESUMO

This study assesses the dosimetric leaf gap (DLG) correction factor in Mobius3D commissioning affected by a couch top platform and calculates the optimal DLG value according to the point dose difference function. DLG optimizations were performed for 3 LINAC machines and a total of 30 patient volumetric modulated arc therapy plans (i.e., 10 plans per each LINAC). Point dose calculations were performed using an automatic dose calculation system in Mobius3D as well as Mobis3D calculation using a Mobius Verification Phantom (MVP)-based quality assurance plan with a carbon fiber couch top. Subsequently, the results were compared with measurement data. The averaged point dose measured for the MVP with a couch top decreased by approximately 2% relative to that without the couch top. The average of the optimal DLG factors increased by 1.153 mm due to the couch top effect for a dose decrease of 2% at the measured point. In the procedure of Mobius beam commissioning, users should adjust the DLG correction factor using a specific phantom (including MVP) with a couch top structure. If the DLG optimization were performed by using MVP automatic dose calculation system, the factor should be increased by approximately 1.2 mm per 2% dose difference considering user's couch top effect.


Assuntos
Algoritmos , Dosagem Radioterapêutica , Relação Dose-Resposta à Radiação , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
4.
Radiat Oncol ; 13(1): 112, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29903025

RESUMO

BACKGROUND: In intensity modulated radiation therapy (IMRT) quality assurance (QA), evaluation of QA result using a pass/non-pass strategy under an acceptance criterion often suffers from lack of information on how good the plan is in absolute manner. In this study, we suggested adding an index system, previously developed for dose painting technique, to current IMRT QA process for better understanding of QA result. METHODS: The index system consists of three indices, index of achievement (IOA), index of hotness (IOH) and index of coldness (IOC). As indicated by its name, IOA does measure the level of agreement. IOH and IOC, on the other hand, measure the magnitude of overdose and underdose, respectively. A systematic analysis was performed with three 1-dimensional hypothetical dose distributions to investigate the characteristics of the index system. The feasibility of the system was also assessed with clinical volumetric modulated arc therapy (VMAT) QA cases from 8 head & neck and 5 prostate patients. In both simulation studies, certain amount of errors was intentionally induced to each dose distribution. Furthermore, we applied the proposed system to compare calculated with actual measured data for a total of 60 patients (30 head & neck and 30 prostate cases). QA analysis was made using both the index system and gamma method, and results were compared. RESULTS: While the gamma evaluation showed limited sensitivity in evaluating QA result depending on the level of tolerance criteria used, the proposed indices tended to better distinguish plans in terms of the amount of errors. Hotness and coldness of prescribed dose in the plan could be evaluated quantitatively by the indices. CONCLUSIONS: The proposed index system provides information with which IMRT QA result would be better evaluated, especially when gamma pass rates are identical or similar among multiple plans. In addition, the independency of the index system on acceptance criteria would help making clear communications among readers of published articles and researchers in multi-institutional studies.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica/normas , Radioterapia de Intensidade Modulada/normas , Algoritmos , Estudos de Viabilidade , Humanos , Masculino , Planejamento da Radioterapia Assistida por Computador , Sensibilidade e Especificidade
5.
Phys Med ; 32(10): 1284-1291, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27378392

RESUMO

PURPOSE: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room-laser-based alignment system. To verify the feasibility of the RAMS, reproducibility and accuracy tests were conducted. METHODS: RAMS was composed of a room laser sensing array (RLSA), an electric circuit, an analog-to-digital converter (ADC), and a control PC. The RLSA was designed to arrange photodiodes in a pattern that results in the RAMS having a resolution of 1mm. The photodiodes were used for quantitative assessment of the alignment condition. To verify the usability of the developed system, we conducted tests of temporal reproducibility, repeatability, and accuracy. RESULTS: The results of the temporal reproducibility test suggested that the signal of the RAMS was stable with respect to time. Further, the repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. The accuracy test confirmed that the "on" and "off" signals could be distinguished by signal intensity, considering that the "off" signal was below 75% of the "on" signal in every case. In addition, we confirmed that the system can detect 1mm of movement by monitoring the pattern of the "on" and "off" signals. CONCLUSION: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. We expect that the RAMS can propose the potential of the room laser based alignment monitoring method.


Assuntos
Lasers , Monitorização Fisiológica/instrumentação , Posicionamento do Paciente/instrumentação , Fenômenos Biofísicos , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Monitorização Fisiológica/estatística & dados numéricos , Posicionamento do Paciente/estatística & dados numéricos , Reprodutibilidade dos Testes , Design de Software