1.
Scand J Gastroenterol ; 55(7): 848-859, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32684060

RESUMO

BACKGROUND AND AIMS: Accurate biomarkers for quantifying liver fibrosis are important for clinical practice and trial end-points. We compared the diagnostic performance of magnetic resonance imaging (MRI), including gadoxetate-enhanced MRI and 31P-MR spectroscopy, with fibrosis stage and serum fibrosis algorithms in a clinical setting. Also, in a subset of patients, MR- and transient elastography (MRE and TE) was evaluated when available. METHODS: Patients were recruited prospectively if they were scheduled to undergo liver biopsy on a clinical indication due to elevated liver enzyme levels without decompensated cirrhosis. Within a month of the clinical work-up, an MR-examination and liver needle biopsy were performed on the same day. Based on late-phase gadoxetate-enhanced MRI, a mathematical model calculated hepatobiliary function (relating to OATP1 and MRP2). The hepatocyte gadoxetate uptake rate (KHep) and the normalised liver-to-spleen contrast ratio (LSC_N10) were also calculated. Nine serum fibrosis algorithms were investigated (GUCI, King's Score, APRI, FIB-4, Lok-Index, NIKEI, NASH-CRN regression score, Forns' score, and NAFLD-fibrosis score). RESULTS: The diagnostic performance (AUROC) for identification of significant fibrosis (F2-4) was 0.78, 0.80, 0.69, and 0.78 for MRE, TE, LSC_N10, and GUCI, respectively. For the identification of advanced fibrosis (F3-4), the AUROCs were 0.93, 0.84, 0.81, and 0.82 respectively. CONCLUSION: MRE and TE were superior for non-invasive identification of significant fibrosis. Serum fibrosis algorithms developed for specific liver diseases are applicable in this cohort of diverse liver diseases aetiologies. Gadoxetate-MRI was sufficiently sensitive to detect the low function losses associated with fibrosis. None was able to efficiently distinguish between stages within the low fibrosis stages.Lay summaryExcessive accumulation of scar tissue, fibrosis, in the liver is an important aspect in chronic liver disease. To replace the invasive needle biopsy, we have explored non-invasive methods to assess liver fibrosis. In our study we found that elastographic methods, which assess the mechanical properties of the liver, are superior in assessing fibrosis in a clinical setting. Of interest from a clinical trial point-of-view, none of the tested methods was sufficiently accurate to distinguish between adjacent moderate fibrosis stages.


Assuntos
Biomarcadores/sangue , Técnicas de Imagem por Elasticidade , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Área Sob a Curva , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Suécia , Adulto Jovem
2.
PLoS Comput Biol ; 15(6): e1007157, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31237870

RESUMO

Estimation of liver function is important to monitor progression of chronic liver disease (CLD). A promising method is magnetic resonance imaging (MRI) combined with gadoxetate, a liver-specific contrast agent. For this method, we have previously developed a model for an average healthy human. Herein, we extended this model, by combining it with a patient-specific non-linear mixed-effects modeling framework. We validated the model by recruiting 100 patients with CLD of varying severity and etiologies. The model explained all MRI data and adequately predicted both timepoints saved for validation and gadoxetate concentrations in both plasma and biopsies. The validated model provides a new and deeper look into how the mechanisms of liver function vary across a wide variety of liver diseases. The basic mechanisms remain the same, but increasing fibrosis reduces uptake and increases excretion of gadoxetate. These mechanisms are shared across many liver functions and can now be estimated from standard clinical images.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Gadolínio DTPA/farmacocinética , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/metabolismo , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Reprodutibilidade dos Testes , Adulto Jovem
3.
J Magn Reson Imaging ; 50(1): 325-333, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30637926

RESUMO

BACKGROUND: Liver iron content (LIC) in chronic liver disease (CLD) is currently determined by performing an invasive liver biopsy. MRI using R2* relaxometry is a noninvasive alternative for estimating LIC. Fat accumulation in the liver, or proton density fat fraction (PDFF), may be a possible confounder of R2* measurements. Previous studies of the effect of PDFF on R2* have not used quantitative LIC measurement. PURPOSE: To assess the associations between R2*, LIC, PDFF, and liver histology in patients with suspected CLD. STUDY TYPE: Prospective. POPULATION: Eighty-one patients with suspected CLD. FIELD STRENGTH/SEQUENCE: 1.5 T. Multiecho turbo field echo to quantify R2*. PRESS MRS to quantify PDFF. ASSESSMENT: Each patient underwent an MR examination, followed by two needle biopsies immediately following the MR examination. The first biopsy was used for conventional histological assessment of LIC, whereas the second biopsy was used to quantitatively measure LIC using mass spectrometry. R2* was correlated with both LIC and PDFF. A correction for the influence of fat on R2* was calculated. STATISTICAL TESTS: Pearson correlation, linear regression, and area under the receiver operating curve. RESULTS: There was a positive linear correlation between R2* and PDFF (R = 0.69), after removing data from patients with elevated iron levels, as defined by LIC. R2*, corrected for PDFF, was the best method for identifying patients with elevated iron levels, with a correlation of R = 0.87 and a sensitivity and specificity of 87.5% and 98.6%, respectively. DATA CONCLUSION: PDFF increases R2*. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:325-333.


Assuntos
Sobrecarga de Ferro/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Biópsia por Agulha , Doença Crônica , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
4.
Gastroenterology ; 153(1): 53-55.e7, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28286210

RESUMO

It is possible to estimate hepatic triglyceride content by calculating the proton density fat fraction (PDFF), using proton magnetic resonance spectroscopy (1H-MRS), instead of collecting and analyzing liver biopsy specimens to detect steatosis. However, the current PDFF cut-off value (5%) used to define steatosis by magnetic resonance was derived from studies that did not use histopathology as the reference standard. We performed a prospective study to determine the accuracy of 1H-MRS PDFF in the measurement of steatosis using histopathology analysis as the standard. We collected clinical, serologic, 1H-MRS PDFF, and liver biopsy data from 94 adult patients with increased levels of liver enzymes (≥6 mo) referred to the Department of Gastroenterology and Hepatology at Linköping University Hospital in Sweden from 2007 through 2014. Steatosis was graded using the conventional histopathology method and fat content was quantified in biopsy samples using stereologic point counts (SPCs). We correlated the 1H-MRS PDFF findings with SPCs (r = 0.92; P < .001). 1H-MRS PDFF results correlated with histopathology results (ρ = 0.87; P < .001), and SPCs correlated with histopathology results (ρ = 0.88; P < .001). All 25 subjects with PDFF values of 5.0% or more had steatosis based on histopathology findings (100% specificity for PDFF). However, of 69 subjects with PDFF values less than 5.0% (negative result), 22 were determined to have steatosis based on histopathology findings (53% sensitivity for PDFF). Reducing the PDFF cut-off value to 3.0% identified patients with steatosis with 100% specificity and 79% sensitivity; a PDFF cut-off value of 2.0% identified patients with steatosis with 94% specificity and 87% sensitivity. These findings might be used to improve noninvasive detection of steatosis.


Assuntos
Fígado/patologia , Espectroscopia de Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/patologia , Triglicerídeos/análise , Adiposidade , Adulto , Idoso , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Sensibilidade e Especificidade
5.
Eur J Radiol Open ; 2: 19-25, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26937432

RESUMO

OBJECTIVES: To qualitatively evaluate late dynamic contrast phases, 10, 20 and 30 min, after administration of Gd-EOB-DTPA with regard to biliary excretion in patients presenting with elevated liver enzymes without clinical signs of cirrhosis or hepatic decompensation and to compare the visual assessment of contrast agent excretion with histo-pathological fibrosis stage, contrast uptake parameters and blood tests. METHODS: 29 patients were prospectively examined using 1.5 T MRI. The visually assessed presence or absence of contrast agent for each of five anatomical regions in randomly reviewed time-series was summarized on a four grade scale for each patient. The scores, including a total visual score, were related to the histo-pathological findings, the quantitative contrast agent uptake parameters, expressed as K Hep or LSC_N, and blood tests. RESULTS: No relationship between the fibrosis grade or contrast uptake parameters could be established. A negative correlation between the visual assessment and alkaline phosphatase (ALP) was found. Comparing a sub-group of cholestatic patients with fibrosis score and Gd-EOB-DTPA dynamic parameters did not add any additional significant correlation. CONCLUSIONS: No correlation between visually assessed biliary excretion of Gd-EOB-DTPA and histo-pathological or contrast uptake parameters was found. A negative correlation between the visual assessment and alkaline phosphatase (ALP) was found.

6.
Eur J Radiol Open ; 2: 66-70, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26937438

RESUMO

PURPOSE: Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and 'G abs,Elastic') MRE are comparable. MATERIALS AND METHODS: Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. RESULTS: Stiffness correlated well with the elasticity, R (2) = 0.96 (P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with 'G abs,Elastic' R (2) = 0.96 (P < 0.001; slope = 0.95, intercept = 0.28 kPa). CONCLUSION: This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression.

7.
J Magn Reson Imaging ; 42(2): 468-76, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25355066

RESUMO

PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneities METHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons. RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint⁡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6). CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.


Assuntos
Tecido Adiposo/anatomia & histologia , Artefatos , Água Corporal/metabolismo , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/metabolismo , Adulto , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Técnica de Subtração
8.
Eur Radiol ; 23(1): 174-81, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22836161

RESUMO

OBJECTIVES: To apply dynamic contrast-enhanced (DCE) MRI on patients presenting with elevated liver enzymes without clinical signs of hepatic decompensation in order to quantitatively compare the hepatocyte-specific uptake of Gd-EOB-DTPA with histopathological fibrosis stage. METHODS: A total of 38 patients were prospectively examined using 1.5-T MRI. Data were acquired from regions of interest in the liver and spleen by using time series of single-breath-hold symmetrically sampled two-point Dixon 3D images (non-enhanced, arterial and venous portal phase; 3, 10, 20 and 30 min) following a bolus injection of Gd-EOB-DTPA (0.025 mmol/kg). The signal intensity (SI) values were reconstructed using a phase-sensitive technique and normalised using multiscale adaptive normalising averaging (MANA). Liver-to-spleen contrast ratios (LSC_N) and the contrast uptake rate (K (Hep)) were calculated. Liver biopsy was performed and classified according to the Batts and Ludwig system. RESULTS: Area under the receiver-operating characteristic curve (AUROC) values of 0.71, 0.80 and 0.78, respectively, were found for K (Hep), LSC_N10 and LSC_N20 with regard to severe versus mild fibrosis. Significant group differences were found for K (Hep) (borderline), LSC_N10 and LSC_N20. CONCLUSIONS: Liver fibrosis stage strongly influences the hepatocyte-specific uptake of Gd-EOB-DTPA. Potentially the normalisation technique and K (Hep) will reduce patient and system bias, yielding a robust approach to non-invasive liver function determination.


Assuntos
Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Cirrose Hepática/patologia , Adulto , Idoso , Área Sob a Curva , Biópsia , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Software , Ultrassonografia de Intervenção
9.
Eur J Radiol ; 66(2): 313-20, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17646074

RESUMO

31P-MRS using DRESS was used to compare absolute liver metabolite concentrations (PME, Pi, PDE, gammaATP, alphaATP, betaATP) in two distinct groups of patients with chronic diffuse liver disorders, one group with steatosis (NAFLD) and none to moderate inflammation (n=13), and one group with severe fibrosis or cirrhosis (n=16). All patients underwent liver biopsy and extensive biochemical evaluation. A control group (n=13) was also included. Absolute concentrations and the anabolic charge, AC=[PME]/([PME]+[PDE]), were calculated. Comparing the control and cirrhosis groups, lower concentrations of PDE (p=0.025) and a higher AC (p<0.001) were found in the cirrhosis group. Also compared to the NAFLD group, the cirrhosis group had lower concentrations of PDE (p=0.01) and a higher AC (p=0.009). No significant differences were found between the control and NAFLD group. When the MRS findings were related to the fibrosis stage obtained at biopsy, there were significant differences in PDE between stage F0-1 and stage F4 and in AC between stage F0-1 and stage F2-3. Using a PDE concentration of 10.5mM as a cut-off value to discriminate between mild, F0-2, and advanced, F3-4, fibrosis the sensitivity and specificity were 81% and 69%, respectively. An AC cut-off value of 0.27 showed a sensitivity of 93% and a specificity of 54%. In conclusion, the results suggest that PDE is a marker of liver fibrosis, and that AC is a potentially clinically useful parameter in discriminating mild fibrosis from advanced.


Assuntos
Cirrose Hepática/patologia , Espectroscopia de Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Diagnóstico Diferencial , Fígado Gorduroso/metabolismo , Fígado Gorduroso/patologia , Feminino , Humanos , Fígado/metabolismo , Fígado/patologia , Cirrose Hepática/metabolismo , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Isótopos de Fósforo , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Estatísticas não Paramétricas
10.
Eur Radiol ; 15(1): 148-57, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15351899

RESUMO

Phosphorus-31 NMR spectroscopy using slice selection (DRESS) was used to investigate the absolute concentrations of metabolites in the human liver. Absolute concentrations provide more specific biochemical information compared to spectrum integral ratios. Nine patients with histopathologically proven diffuse liver disease and 12 healthy individuals were examined in a 1.5-T MR scanner (GE Signa LX Echospeed plus). The metabolite concentration quantification procedures included: (1) determination of optimal depth for the in vivo measurements, (2) mapping the detection coil characteristics, (3) calculation of selected slice and liver volume ratios using simple segmentation procedures and (4) spectral analysis in the time domain. The patients had significantly lower concentrations of phosphodiesters (PDE), 6.3+/-3.9 mM, and ATP-beta, 3.6+/-1.1 mM, (P<0.05) compared with the control group (10.0+/-4.2 mM and 4.2+/-0.3 mM, respectively). The concentrations of phosphomonoesters (PME) were higher in the patient group, although this was not significant. Constructing an anabolic charge (AC) based on absolute concentrations, [PME]/([PME] + [PDE]), the patients had a significantly larger AC than the control subjects, 0.29 vs. 0.16 (P<0.005). Absolute concentration measurements of phosphorus metabolites in the liver are feasible using a slice selective sequence, and the technique demonstrates significant differences between patients and healthy subjects.


Assuntos
Hepatopatias/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Concentração de Íons de Hidrogênio , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Isótopos de Fósforo , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Estatísticas não Paramétricas