Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 35(6): 1026-31, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19171416

RESUMO

High-intensity focused ultrasound (HIFU) has shown great potential for replacing surgery in many applications. In this work, HIFU was used to destroy Escherichia coli (E. coli) biofilms that had been grown on chambered microscope slides. Biofilms are central to the pathogenesis and persistence of nosocomial (hospital-acquired) infections associated with indwelling medical devices. The slides were exposed to 9.1 mus pulses at a pulse repetition frequency of 1000 Hz. The pulses were generated by a 1.1 MHz spherically focused source with a focal length of 6.3 cm and an active diameter of 7 cm. The peak rarefactional pressure for the pulses was varied as 3.1, 4.1, 5.2, 6.2 and 7.6 MPa in addition to a sham where the biofilms were not exposed. The effectiveness of the treatment was assessed by determining the number of colony forming units (CFU) remaining following exposure of the bacteria to HIFU. Most of the biofilms treated at the higher exposures of 6.2 and 7.6 MPa had no detectable CFU, indicating that bacteria in the biofilm were killed by the treatment or that treatment disrupted the biofilm and released bacteria from the slide. However, the ability of some bacteria to survive at the higher exposure settings needs to be resolved prior to implementing the treatment clinically.


Assuntos
Biofilmes/crescimento & desenvolvimento , Escherichia coli/fisiologia , Terapia por Ultrassom/métodos , Contagem de Colônia Microbiana , Escherichia coli/crescimento & desenvolvimento
2.
Artigo em Inglês | MEDLINE | ID: mdl-19163706

RESUMO

Ultrasound histotripsy has shown great potential for replacing surgery in many applications. In this work, a modification of ultrasound histotripsy was used to destroy Escherichia coli (E. coli) biofilms that had been grown on chambered microscope slides. Biofilms are central to the pathogenesis and persistence of nosocomial (hospital-acquired) infections associated with indwelling medical devices. The slides were exposed to 9.1 micros pulses at a pulse repetition frequency of 1000 Hz. The pulses were generated by a 1.1 MHz spherically focused source with a focal length of 6.3 cm and an active diameter of 7 cm. The peak rarefactional pressure for the pulses was varied as 3.1, 4.1, 5.2, 6.2, and 7.6 MPa in addition to a sham where the biofilms were not exposed. The effectiveness of the treatment was assessed by determining the viable number of colony forming units (CFU) remaining in the biofilm. Most of the biofilms treated at the higher exposures of 6.2 and 7.6 MPa had no remaining CFU indicating that the biofilm was completely destroyed. However, the persistence of some CFU for some of the biofioms at the higher exposure settings needs to be resolved prior to implementing the treatment clinically.


Assuntos
Biofilmes , Escherichia coli/metabolismo , Ultrassom , Engenharia/métodos , Técnicas Microbiológicas , Física/métodos , Pressão , Células-Tronco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...