Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Microbiol ; 54(8): 2008-13, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27194690

RESUMO

Herpes simplex virus (HSV) causes acute and relapsing symptoms characterized by ulcerative lesions. Laboratory diagnosis of HSV in cutaneous or mucocutaneous lesions has historically been performed with the use of viral cell culture systems; however, these tests are laborious and suffer decreased sensitivity for advanced-stage lesions. The recent availability of FDA-cleared moderately complex assays has resulted in the increased use of molecular diagnostics for the routine detection of HSV in superficial swab specimens. We performed a clinical evaluation of the recently FDA-cleared illumigene HSV 1&2 loop-mediated isothermal amplification (LAMP) assay (Meridian Bioscience, Cincinnati OH) for the detection and differentiation of HSV-1 and HSV-2 in cutaneous and mucocutaneous swab specimens. A total of 1,153 clinical swab specimens were collected and tested at 7 different clinical centers. Each specimen was tested for the presence of HSV-1 and HSV-2 using the illumigene assay, and results were compared to those of the enzyme-linked virus-inducible system (ELVIS) as the reference method. Overall, the illumigene assay demonstrated a sensitivity and specificity of 94.8% and 95.5%, respectively, for the detection of HSV-1. Detection of HSV-2 was similar, with a sensitivity of 98.9% and a specificity of 95.5%. Discrepant analysis was performed using an alternative molecular test (AmpliVue HSV1+2 assay; Quidel Molecular, San Diego, CA) on 91/99 specimens that were recorded as false positive (FP) or false negative (FN) compared to the reference method. In total, 57/78 (73%) FP and 9/13 (69%) FN illumigene results were supported by the AmpliVue result. The illumigene HSV 1&2 assay demonstrated high sensitivity and specificity to detect and differentiate HSV in clinical specimens and identified 57 additional specimens that were positive for HSV compared to culture. The use of LAMP eliminates the need for the cycling of temperatures and provides results in less than 60 min, with approximately 2 min of hands-on time per specimen.


Assuntos
Herpes Genital/diagnóstico , Herpes Simples/diagnóstico , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
2.
Arch Ophthalmol ; 126(11): 1493-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19001215

RESUMO

OBJECTIVE: To investigate the effect of storage temperature on the ability of contact lens solutions to inhibit growth of Fusarium species. A 2006 Food and Drug Administration inspection of Bausch & Lomb's Greenville, South Carolina, manufacturing site indicated that Bausch & Lomb failed to regulate storage and transport temperatures of their products. METHODS: Six contact lens solutions were studied: ReNu with MoistureLoc, ReNu MultiPlus, COMPLETE Moistureplus, AQuify, Clear Care, and OPTI-FREE RepleniSH. Two bottles of each solution were separately stored at room temperature and 60 degrees C for 4 weeks, serially diluted, and then tested for their ability to inhibit growth of 11 Fusarium isolates (7 of which were associated with the keratitis epidemic). RESULTS: ReNu with MoistureLoc demonstrated the greatest decline in efficacy after 60 degrees C storage. Clear Care and ReNu MultiPlus performed the best. Regarding the keratitis epidemic isolates only, the ReNu with MoistureLoc bottle stored at room temperature allowed growth in 27 of 84 combinations vs 67 of 84 combinations with the 60 degrees C-stored bottle. CONCLUSIONS: When exposed to prolonged temperature elevation, ReNu with MoistureLoc loses its in vitro fungistatic activity to a much greater extent than other products. Improper temperature control of ReNu with MoistureLoc may have contributed to the Fusarium keratitis epidemic of 2004-2006.


Assuntos
Soluções para Lentes de Contato/farmacologia , Armazenamento de Medicamentos/métodos , Fusarium/efeitos dos fármacos , Fusarium/crescimento & desenvolvimento , Temperatura Alta , Lentes de Contato/microbiologia , Desinfecção/normas , Infecções Oculares Fúngicas/epidemiologia , Infecções Oculares Fúngicas/microbiologia , Humanos , Ceratite/epidemiologia , Ceratite/microbiologia , Micoses/epidemiologia , Micoses/microbiologia , Projetos Piloto , Meios de Transporte
3.
Trans Am Ophthalmol Soc ; 106: 117-26; discussion 126-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19277227

RESUMO

PURPOSE: A 2006 US Food and Drug Administration (FDA) inspection of Bausch & Lomb's (B&L's) Greenville, South Carolina, manufacturing site indicated that B&L failed to regulate storage and transport temperatures of their products. The present study investigated the effect of storage temperature on the ability of contact lens solutions to inhibit growth of Fusarium species. METHODS: SIX CONTACT LENS SOLUTIONS WERE STUDIED: ReNu with MoistureLoc (ReNu ML), ReNu MultiPlus, Complete Moistureplus, AQuify, Clear Care, and OPTI-FREE RepleniSH. Two bottles of each solution were separately stored at room temperature and 60 degrees C for 4 weeks, serially diluted, then tested for their ability to inhibit growth of 11 Fusarium isolates (7 of which were associated with the keratitis epidemic). RESULTS: ReNu ML demonstrated the greatest decline in efficacy after 60 degrees C storage. Clear Care and ReNu MultiPlus performed the best. Regarding the keratitis epidemic isolates only, the ReNu ML bottle stored at room temperature allowed growth in 27 of 84 combinations vs 67 of 84 combinations with the 60 degrees C stored bottle. CONCLUSIONS: When exposed to prolonged temperature elevation, ReNu ML loses its in vitro fungistatic activity to a much greater extent than other products. Improper temperature control of ReNu ML may have contributed to the Fusarium keratitis epidemic of 2004-2006.


Assuntos
Soluções para Lentes de Contato/farmacologia , Armazenamento de Medicamentos/métodos , Fusarium/efeitos dos fármacos , Fusarium/crescimento & desenvolvimento , Temperatura Alta , Lentes de Contato/microbiologia , Desinfecção/normas , Infecções Oculares Fúngicas/epidemiologia , Infecções Oculares Fúngicas/microbiologia , Humanos , Ceratite/epidemiologia , Ceratite/microbiologia , Micoses/epidemiologia , Micoses/microbiologia , Projetos Piloto , Meios de Transporte
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...