Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Phys Technol ; 16(3): 366-372, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37248443

RESUMO

A calibration phantom made of Derlin requires manual translational and rotational adjustments when calibrating a light-section-based optical surface monitoring system (VOXELAN) with a phantom material that insufficiently reflects the red-slit laser of the system. This study aimed to develop a new calibration phantom using different materials and to propose a procedure that minimizes setup errors. The new phantom, primarily made of PET100, which exhibits good reflectivity without scattering or attenuating the red-slit laser at the phantom surface, was shaped in a manner similar to that of previous designs. The detection accuracy and stability were evaluated using six different regions of interest (ROIs) and compared with previous phantom designs. The coordinate coincidence between the machine and VOXELAN was compared for both phantom designs. The detection accuracy and stability of the new phantom in the reference ROI setting were found to be better than those of previous phantoms. In the lateral, longitudinal, and vertical directions, the coordinate coincidences in translational directions for the previous phantom were obtained at 1.07 ± 0.66, 1.46 ± 0.47, and 0.26 ± 0.83 mm, whereas those for the new phantom were obtained at 0.28 ± 0.21, 0.18 ± 0.30, and - 0.30 ± 0.29 mm, respectively. The rotational errors of the two phantoms were identical. The new phantom exhibited improved detection stability because of its good reflectivity. Additionally, the new placement procedure was linked to the six-degrees-of-freedom couch. A combination of the new phantom and its new placement procedure is suitable for coordinate calibration of VOXELAN.


Assuntos
Calibragem , Imagens de Fantasmas
2.
Clin Lung Cancer ; 22(6): 562-569, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34253472

RESUMO

BACKGROUND: Routine positron emission tomography/computed tomography (PET/CT) has been recommended even for clinical stage I non-small-cell lung cancer (NSCLC). In spite of the progress in the screening procedure, and revisions to TNM classification, there is no evidence to support brain imaging screening of patients assessed with the current staging protocol including PET/CT. MATERIALS AND METHODS: We retrospectively investigated the frequency of extrathoracic metastasis in 466 consecutive patients with clinical stage T1-2 N0 NSCLC with the complete staging assessment comprised of thin-section CT, PET/CT, and brain contrast-enhanced magnetic resonance imaging between 2008 and 2016. All patients were reclassified according to the eighth edition of the tumor, node, and metastasis (TNM) classification. RESULTS: Among all patients, 70% of the tumors were pure solid and 30% had part-solid ground-glass opacity on thin-section CT, and 388 (83%) and 78 (17%) were classified into clinical stages T1 and T2, respectively. Eight patients (1.7%) had extrathoracic metastasis, including 3 (0.6%) with brain metastasis, and all showed pure-solid tumors. The frequency of extrathoracic and brain metastasis was 1.0% and 0.5% in 388 T1 patients, and 5.0% and 3.0% in 78 T2 patients. Although brain metastases were detected in 2 of 7 patients (29%) with PET/CT detectable extrathoracic metastases and 1 of 459 patients (0.2%) without PET/CT detectable extrathoracic metastasis, there were no neurologically asymptomatic brain metastases in patients with early-stage NSCLC confirmed by PET/CT. CONCLUSION: Routine screening of brain imaging is unnecessary in patients with early-stage NSCLC, assessed with the current staging protocol including PET/CT.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Neuroimagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Estudos Retrospectivos , Neoplasias Torácicas/diagnóstico por imagem
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(8): 667-73, 2016 08.
Artigo em Japonês | MEDLINE | ID: mdl-27546080

RESUMO

Dose volume histogram (DVH) is one of the methods for evaluating the feasibility of radiotherapy plans. It is difficult to thoroughly comprehend an evaluation of each plan at a glance and to give a concise presentation of the case at conference. In this study, we provide a useful program that will fulfill such a purpose on a clinical setting. We have revised our protocols of radiotherapy planning, developed the program using Visual Basic 2010, which could facilitate an evaluation of DVH, and used it for checking plans and presentation at case conference. Since our DVH analysis program shows a result of DVH in a simple way, such as "OK (Okay)" or "NG (No good)", we can promptly comprehend the results of each radiotherapy plan at ease. This program easily tells us accordance between plans and protocols. We found this program useful and worth spreading.


Assuntos
Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Radioterapia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...