Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Saudi Med J ; 43(8): 959-964, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35964963

RESUMO

OBJECTIVES: To find any correlation between the clinical response as per International Working Myeloma Group (IWMG) response criteria and the radiological response at the end of treatment. METHODS: A retrospective cohort study was conducted, total of 39 patients whom diagnosed with multiple myeloma (MM) between January 2010 and December 2018 and fulfilled the study criteria were included. RESULTS: The high sensitivity and specificity of positron emission tomography/computed tomography (PET/CT) in detecting osteolytic myeloma lesions in the bones was strongly emphasized in our study. Follow up PET/CT, we found that while 17 patients showed complete remission in PET/CT, and 14 of these of patients demonstrated a complete clinical response at end of therapy assessment. CONCLUSION: Although we did not find a statistically significant correlation between the response versus metabolic activity and the number of bone/bone marrow lesions, however, our study was limited by the absence of clear criteria for defining disease response in PET/CT in MM patients. Further prospective analysis would be needed to establish a defined criterion.


Assuntos
Doenças Ósseas , Mieloma Múltiplo , Doenças Ósseas/diagnóstico por imagem , Doenças Ósseas/etiologia , Fluordesoxiglucose F18 , Humanos , Mieloma Múltiplo/complicações , Mieloma Múltiplo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos
2.
Ann Saudi Med ; 41(2): 86-90, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33818150

RESUMO

BACKGROUND: Thyrotoxicosis is a common medical problem. Thyroid nuclear imaging with either I123 or technetium-99m (Tc-99m) pertechnetate are used to determine the cause. Although I123 has been the standard technique, Tc-99m pertechnetate is now commonly used, acceptable and easier to perform. The commonly used normal value of Tc-99m pertechnetate is 1-4%, but lower normal values have been reported in different populations. OBJECTIVE: Determine normal reference range of Tc-99m pertechne-tate thyroid uptake for thyroid scintigraphy in Saudi Arabia. DESIGN: Retrospective, cross-sectional. SETTING: Nuclear medicine service at tertiary care center in Riyadh. PATIENTS AND METHODS: We used data from biochemically euthyroid patients who underwent a thyroid Tc-99m pertechnetate scan while having parathyroid scintigraphy for hyperparathyroidism between April 2009 to April 2019. Medical records and biochemical thyroid function tests were reviewed and Tc-99m pertechnetate thyroid uptake values were determined for each patient. MAIN OUTCOME MEASURES: Thyroid uptake of Tc-99m pertechne-tate in euthyroid patients. SAMPLE SIZE: 167 RESULTS: The mean and median uptake of Tc-99m pertechnetate in euthyroid patients were 0.86% and 1.0%, respectively, and the inter-quartile range was 0.0-1.0%. The normal reference range in the study population was 0.2-2%. Thyroid uptake inversely correlated with age in females (r=-0.37, P<.001), males (r=-0.46, P=.001), and for all patients (r=?0.39, P<.0001). CONCLUSION: The range for normal thyroid Tc-99m pertechnetate was lower than the standard 1-4% range. Moreover, uptake decreased with age. Further studies are needed to establish the normal age-adjusted uptake for the thyroid Tc-99m pertechnetate scan. LIMITATIONS: Single center and retrospective. CONFLICT OF INTEREST: None.


Assuntos
Pertecnetato Tc 99m de Sódio , Tecnécio , Estudos Transversais , Feminino , Humanos , Masculino , Compostos Radiofarmacêuticos , Valores de Referência , Estudos Retrospectivos , Arábia Saudita , Glândula Tireoide/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...