Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 142(1): 47-52.e3, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21683838

RESUMO

OBJECTIVES: Gastroesophageal reflux disease (GERD) is implicated as a risk factor for bronchiolitis obliterans syndrome after lung transplantation, but its effects on acute rejection, early allograft function, and survival are unclear. Therefore, we sought to systematically understand the time-related impact of pretransplant GERD on graft function (spirometry), mortality, and acute rejection early after lung transplantation. METHODS: From January 2005 to July 2008, 215 patients underwent lung transplantation; 114 had preoperative pH testing, and 32 (28%) had objective evidence of GERD. Lung function was assessed by forced 1-second expiratory volume (FEV(1); percent of predicted) in 97 patients, mortality by follow-up (median, 2.2 years), and acute rejection by transbronchial biopsy. RESULTS: Pretransplant GERD was associated with decreased FEV(1) early after lung transplantation (P = .01) such that by 18 months, FEV(1) was 70% of predicted in double lung transplant patients with GERD versus 83% among non-GERD patients (P = .05). A similar decrease was observed in single lung transplantation (50% vs 60%, respectively; P = .09). GERD patients had lower survival early after transplant ( P = .02)-75% versus 90%. Presence of GERD did not affect acute rejection (P = .6). CONCLUSIONS: For lung transplant recipients, pretransplant GERD is associated with worse early allograft function and survival, but not increased acute rejection. The compromise in lung function is substantial, such that FEV(1) after double lung transplant in GERD patients approaches that of single lung transplant in non-GERD patients. We advocate thorough testing for GERD before lung transplantation; if identified, aggressive therapy early after transplant, including fundoplication, may prove efficacious.


Assuntos
Refluxo Gastroesofágico/complicações , Rejeição de Enxerto/etiologia , Sobrevivência de Enxerto , Pneumopatias/cirurgia , Transplante de Pulmão/efeitos adversos , Pulmão/cirurgia , Doença Aguda , Adulto , Idoso , Biópsia , Feminino , Volume Expiratório Forçado , Refluxo Gastroesofágico/mortalidade , Rejeição de Enxerto/patologia , Humanos , Estimativa de Kaplan-Meier , Pulmão/fisiopatologia , Pneumopatias/complicações , Pneumopatias/fisiopatologia , Transplante de Pulmão/mortalidade , Masculino , Pessoa de Meia-Idade , Dinâmica não Linear , Ohio , Medição de Risco , Fatores de Risco , Espirometria , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
2.
J Thorac Cardiovasc Surg ; 133(5): 1277-85, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17467441

RESUMO

OBJECTIVE: Although endovascular repair of the descending thoracic aorta has emerged as a viable treatment option, little is known about its potential to treat patients diagnosed with aortobronchial fistulas. We reviewed our comprehensive thoracic endografting experience with regard to the endovascular management and subsequent outcome of patients with aortobronchial fistulas to assess whether endoluminal graft repair is a realistic option. METHODS: Between February 2000 and November 2005, 255 patients were successfully treated with an endoluminal graft to the descending thoracic aorta. Indications for intervention included: atherosclerotic aneurysms (109/255, 42.7%), acute and chronic dissections (75/255, 29.4%), miscellaneous (34/255, 13.3%), penetrating aortic ulcers (30/255, 11.8%), and aortobronchial fistulas (7/255, 2.7%). RESULTS: Average patient age was 73.4 +/- 10.1 years, with 4 male patients (4/7, 57.1%) and 3 female patients (3/7, 42.9%). All patients presented with hemoptysis, with 1 patient (1/7, 14.3%) requiring preoperative blood transfusion. Three patients (3/7, 42.9%) were diagnosed with atherosclerotic aneurysms, 3 patients (3/7, 42.9%) had pseudoaneurysms associated with prior open surgical repair, and 1 patient (1/7, 14.3%) had a prior endoluminal graft placed for a traumatic aortic transection. No standard postoperative antibiotic regimen was followed. There were no endoleaks, no incidences of paraplegia, and no endoluminal graft infections. Survival was 100% (7/7) at both 30 days and 1 year, and all patients are currently alive. Follow-up computed tomography was available for all 7 patients, with an average follow-up of 42.6 +/- 28.5 months. CONCLUSIONS: Endovascular management of aortobronchial fistulas appears to be safe and well tolerated, even in surgically high-risk patients, with minimal risk of prosthesis infection. Long-term surveillance and continued investigation are warranted.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Fístula Brônquica/cirurgia , Stents , Fístula Vascular/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Echocardiography ; 23(5): 421-7, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16686630

RESUMO

In this report, we present 12 patients (range 14-76 years, mean 40 +/- 22.7 years) who underwent surgical repair of a ventricular septal defect (VSD). Location, size, and surrounding anatomy of the VSD were assessed prior to intervention in all patients with live/real time three-dimensional transthoracic echocardiography (3DTTE). In 9 patients, measurements of maximum dimension, circumference, and area by 3DTTE correlated well with the same measurements from intraoperative three-dimensional transesophageal echocardiographic (3DTEE) reconstruction. 3DTTE measurement of maximum dimension of VSDs also agreed well with maximum dimension by surgery in 10 patients. Live/real time 3DTTE accurately defined VSD location, size, and surrounding anatomy in all patients studied by us. VSD characterization by live 3DTTE agreed well with surgery descriptions and 3DTEE measurements.


Assuntos
Sistemas Computacionais , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/patologia , Adolescente , Adulto , Idoso , Ecocardiografia Transesofagiana , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
Echocardiography ; 21(8): 737-43, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15546375

RESUMO

We evaluated 44 consecutive patients who underwent standard two-dimensional (2D) and live three-dimensional (3D) transthoracic echocardiography (TTE), as well as left heart catheterization with left ventriculography. Mitral regurgitant vena contracta area (VCA) was obtained by 3D TTE by systematic and sequential cropping of the acquired 3D TTE data set. Assessment of mitral regurgitation (MR) by ventriculography was compared to measurements of VCA by 3D TTE and to 2D TTE measurements of MR jet area to left atrial area (RJA/LAA), RJA alone, vena contracta width (VCW), and calculated VCA. VCA from 3D TTE closely correlated with angiographic grading (rs=0.88) with very little overlap. VCA of <0.2 cm2 correlated with mild MR, 0.2-0.4 cm2 with moderate MR, and >0.4 cm2 with severe MR by angiography. Ventriculographic grading also correlated well with 2D TTE measurements of RJA/LAA (rs=0.79) and RJA alone (rs=0.76) but with more overlap. Assessment of VCW and calculated VCA by 2D TTE agreed least with ventriculography (rs=0.51 and rs=0.55, respectively). Live 3D TTE color Doppler measurements of VCA can be used for quantitative assessment of MR and is comparable to assessment by ventriculography.


Assuntos
Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...