Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Int AIDS Soc ; 24(3): e25677, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33745234

RESUMO

INTRODUCTION: Point-of-care (POC) early infant diagnosis (EID) testing has been shown to dramatically decrease turnaround times from sample collection to caregiver result receipt and time to ART initiation for HIV-positive infants compared to centralized laboratory testing. As governments in sub-Saharan Africa implement POC EID technologies, we report on the feasibility and effectiveness of POC EID testing and the impact of same-day result delivery on rapid ART initiation within national programmes across six countries. METHODS: This pre-/post-evaluation compared centralized laboratory-based (pre) with POC (post) EID testing in 52 facilities across Cameroon, Democratic Republic of Congo, Ethiopia, Kenya, Senegal and Zimbabwe between April 2017 and October 2019 (country-dependent). Data were collected retrospectively from routine records at health facilities for all infants tested under two years of age. Hazard ratios and 95% confidence intervals were calculated to compare time-to-event outcomes, visualized with Kaplan-Meier curves, and the Somers' D test was used to compare continuous outcomes. RESULTS: Data were collected for 2892 EID tests conducted on centralized laboratory-based platforms and 4610 EID tests on POC devices with 127 (4%) and 192 (4%) HIV-positive infants identified, respectively. POC EID significantly reduced the time from sample collection to caregiver result receipt (POC median: 0 days, IQR: 0 to 0 vs. centralized: 35 days, IQR: 26 to 56) and time from sample collection to ART initiation for HIV-positive infants (POC median: 1 day, IQR: 0 to 7 vs. centralized: 39 days, IQR: 26 to 57). With POC testing, 72% of infants received results on the same day as sample collection; HIV-positive infants with a same-day diagnosis had six times the rate of ART initiation compared to those diagnosed one or more days after sample collection (HR: 6.39; 95% CI: 3.44 to 11.85). CONCLUSIONS: Same-day diagnosis and treatment initiation for infants is possible with POC EID within routine government-led and -supported public sector healthcare facilities in resource-limited settings. Given that POC EID allows for rapid ART initiation, aligning to the World Health Organization's recommendation of ART initiation within seven days, its use in public sector programmes has the potential to reduce overall mortality for infants with HIV through early treatment initiation.


Assuntos
Continuidade da Assistência ao Paciente , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Testes Imediatos , Diagnóstico Precoce , Feminino , Programas Governamentais , Humanos , Lactente , Masculino , Avaliação de Programas e Projetos de Saúde , Estudos Retrospectivos
2.
Confl Health ; 15(1): 8, 2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-33568157

RESUMO

BACKGROUND: Civil strife has long been recognized as a significant barrier in the fight against vaccine preventable diseases in several parts of the world. However, little is known about the impact of the ongoing civil strife on the immunisation system in the Northwest (NW) and Southwest (SW) regions of Cameroon, which erupted in late 2016. In this paper, we assessed the effect of the conflict on key immunisation outcomes in the North West and South West regions of Cameroon. METHODS: Data were obtained from the standard EPI data reporting tool, the District Vaccine and Data Management Tool (DVDMT), from all the districts in the two regions. Completed forms were then reviewed for accuracy prior to data entry at central level. Summary statistics were used to estimate the variables of interest for each region for the years 2016 (pre-conflict) and 2019 (during conflict). RESULTS: In the two regions, the security situation has deteriorated in almost all districts, which in turn has disrupted basic healthcare delivery in those areas. A total of 26 facilities were destroyed and 11 healthcare workers killed in both regions. Reported immunisation coverage rates for key antigens including, BCG, DPT-3 and MR, witnessed a dramatic decline between 2016 and 2019, ranging from 22% points decline for BCG in the NW and to 42% points decline for DPT-3 in the SW. Similarly, the proportion of districts with DPT-3 coverage of at least 80% dropped from 75% in 2016 to 11% in 2019 in the NW. In the SW this proportion dropped from 16% in 2016 to 0 % in 2019. CONCLUSION: Our data demonstrates the marked negative impact of the ongoing civil strife on key immunisation outcomes in the two regions and the country at large. This decline could amplify the risk of vaccine preventable diseases vaccine preventable diseases outbreaks in the two regions. Besides the ongoing actions to contain the crises, effective strategies for reaching children in the conflict zones as well as the internally displaced population are needed. There is also the need to rebuild destroyed facilities as well as to protect health facilities and staff from targeted violence.

3.
J Int AIDS Soc ; 24(1): e25663, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33455081

RESUMO

INTRODUCTION: In many low- and middle-income countries, HIV viral load (VL) testing occurs at centralized laboratories and time-to-result-delivery is lengthy, preventing timely monitoring of HIV treatment adherence. Near point-of-care (POC) devices, which are placed within health facility laboratories rather than clinics themselves (i.e. "true" POC), can offer VL in conjunction with centralized laboratories to expedite clinical decision making and improve outcomes, especially for patients at high risk of treatment failure. We assessed impacts of near-POC VL testing on result receipt and clinical action in public sector programmes in Cameroon, Democratic Republic of Congo, Kenya, Malawi, Senegal, Tanzania and Zimbabwe. METHODS: Routine health data were collected retrospectively after introducing near-POC VL testing at 57 public sector health facilities (2017 to 2019, country-dependent). Where possible, key indicators were compared to data from patients receiving centralized laboratory testing using hazard ratios and the Somers' D test. RESULTS: Data were collected from 6795 tests conducted on near-POC and 17614 tests on centralized laboratory-based platforms. Thirty-one percent (2062/6694) of near-POC tests were conducted for high-risk populations: pregnant and breastfeeding women, children and those with suspected failure. Compared to conventional testing, near-POC improved the median time from sample collection to return of results to patient [six vs. sixty-eight days, effect size: -32.2%; 95% CI: -41.0% to -23.4%] and to clinical action for individuals with an elevated HIV VL [three vs. fourty-nine days, effect size: -35.4%; 95% CI: -46.0% to -24.8%]. Near-POC VL results were two times more likely to be returned to the patient within 90 days compared to centralized tests [50% (1781/3594) vs. 27% (4172/15271); aHR: 2.22, 95% CI: 2.05 to 2.39]. Thirty-seven percent (340/925) of patients with an elevated near-POC HIV VL result had documented clinical follow-up actions within 30 days compared to 7% (167/2276) for centralized testing. CONCLUSIONS: Near-POC VL testing enabled rapid test result delivery for high-risk populations and led to significant improvements in the timeliness of patient result receipt compared to centralized testing. While there was some improvement in time-to-clinical action with near-POC VL testing, major gaps remained. Strengthening of systems supporting the utilization of results for patient management are needed to truly capitalize on the benefits of decentralized testing.


Assuntos
Infecções por HIV/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Carga Viral , Adolescente , Adulto , África Subsaariana , Idoso , Criança , Pré-Escolar , Feminino , Infecções por HIV/tratamento farmacológico , Instalações de Saúde , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Gravidez , Prática de Saúde Pública , Estudos Retrospectivos , Carga Viral/métodos , Adulto Jovem
4.
Vaccine ; 38(48): 7683-7687, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-33082013

RESUMO

Vaccine Vial Monitors (VVM) are used to estimate if a vaccine has been exposed to excessive hot temperatures. This endpoint measurement is useful in determining if a vaccine is safe to be administered to a patient, but it does not pinpoint where in the cold chain a vaccine was exposed to excessive heat. With the expansion and technological advancement of cold chain equipment temperature monitoring, it is now possible to remotely estimate VVM status as a vaccine moves through the cold chain. In the present study, we examine the application of the mathematical principles backing VVMs on real, continuous, temperature monitoring data in Africa. Results suggest that exposure to short bursts of hot temperature or long power outages may still allow for safe distribution of affected vaccines. The remaining VVM life calculation could improve managerial visibility into cold chain equipment performance allowing for better data-driven planning and maintenance decisions.


Assuntos
Armazenamento de Medicamentos , Refrigeração , Vacinas , África , Temperatura Baixa , Humanos , Temperatura
5.
PLoS One ; 15(1): e0226987, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31910221

RESUMO

BACKGROUND: Globally, nearly 22 million HIV-infected patients are currently accessing antiretroviral treatment; however, almost one million people living with HIV died of AIDS-related illnesses in 2018. Advanced HIV disease remains a significant issue to curb HIV-related mortality. METHODS: We analyzed 864,389 CD4 testing records collected by 1,016 Alere Pima Analyzers implemented at a variety of facilities, including peripheral facilities, between January 2012 and December 2016 across four countries in sub-Saharan Africa. Routinely collected data and programmatic records were used to analyze the median CD4 counts and proportions of patients with advanced HIV disease by country, facility type, and year. RESULTS: Median CD4 counts were between 409-444 cells/ul each year since 2012 with a median in 2016 of 444 cells/ul (n = 319,829). The proportion of test results returning CD4 counts above 500 cells/ul has increased slowly each year with 41.8% (95% CI: 41.6-41.9%) of tests having a CD4 count above 500 cells/ul in 2016. Median CD4 counts were similar across facility types. The proportion of test results indicating advanced HIV disease has remained fairly consistent: 19.4% (95% CI: 18.8-20.1%) in 2012 compared to 16.1% (95% CI: 16.0-16.3%) in 2016. The proportion of test results indicating advanced HIV disease annually ranged from 14.5% in Uganda to 29.8% in Cameroon. 6.9% (95% CI: 6.8-7.0%) of test results showed very advanced HIV disease (CD4<100 cells/ul) in 2016. CONCLUSIONS: The proportion of CD4 test results indicating advanced disease was relatively high and consistent across four high HIV burden countries.


Assuntos
Instituições de Assistência Ambulatorial , Infecções por HIV/diagnóstico , Atenção Primária à Saúde , África Subsaariana/epidemiologia , Contagem de Linfócito CD4 , Camarões , Coleta de Dados , Infecções por HIV/sangue , Infecções por HIV/epidemiologia , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Uganda
6.
PLoS One ; 14(7): e0219021, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31276477

RESUMO

BACKGROUND: Since 2010, point-of-care (POC) CD4 testing platforms have been introduced in both urban and rural settings to expand access to testing by bringing diagnostic services closer to patients. We conducted an analysis of routinely collected CD4 testing data to determine the invalid result rates associated with POC CD4 testing. METHODS: We analyzed 981,152 CD4 testing records collected from Alere Pima Analyzers between January 2011 and December 2016 across five countries in sub-Saharan Africa. Routinely collected data and programmatic records were used to determine the rate of invalid test results per month, by facility type, and by operator based on cumulative usage during the study period. In addition, frequency of invalid test types and utilization of control beads were assessed. RESULTS: Across the five countries, 75,530 invalid messages were returned, resulting in an overall invalid result rate of 7.7%. The invalid result rate by country ranged from 6.6% to 11.2%. Invalid result rates were consistent across facility types. Invalid result rates were inversely correlated with operator usage: low volume operators (<50 tests over study period) experienced an invalid result rate of 10.2%, while high volume operators (>500 tests over study period) experienced an invalid result rate of 5.5%. Two invalid result types (exposure position control and reagent control) accounted for nearly 50% of invalid results. Routine data showed that control beads were run on 88.3% of days that the device was used. CONCLUSIONS: Our analysis found that the rate of invalid results was consistent across all types of health facilities, indicating that decentralization of POC CD4 testing to lower level health facilities did not exhibit high invalid result rates or increase cartridge wastage. Additionally, invalid result rates were inversely correlated to operator usage, with high-volume operators experiencing lower invalid result rates than low-volume operators. POC CD4 testing can, therefore, be performed in decentralized national testing programs; however, adequate training, quality assurance, routine monitoring, and ongoing mentorship should also be implemented for success.


Assuntos
Infecções por HIV/imunologia , Testes Imediatos , Tecnologia sem Fio/instrumentação , África Subsaariana , Contagem de Linfócito CD4 , Estudos Transversais , Humanos , Saúde Pública , Reprodutibilidade dos Testes , Estudos Retrospectivos , Serviços de Saúde Rural
7.
Pediatr Infect Dis J ; 37(1): 103-107, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28787383

RESUMO

BACKGROUND: Although most African countries offer hepatitis B immunization through a 3-dose vaccine series recommended at 6, 10 and 14 weeks of age, very few provide birth dose vaccination. In support of Cameroon's national plan to implement the birth dose vaccine in 2017, we investigated predictors of infant hepatitis B virus (HBV) vaccination under the current program. METHODS: Using the 2011 Demographic Health Survey in Cameroon, we identified women with at least one living child (age 12-60 months) and information about the hepatitis B vaccine series. Vaccination rates were calculated, and logistic regression modeling was used to identify factors associated with 3-dose series completion. Changes over time were assessed with linear logistic model. RESULTS: Among 4594 mothers analyzed, 66.7% (95% confidence interval [CI]: 64.1-69.3) of infants completed the hepatitis B vaccine series; however, an average 4-week delay in series initiation was noted with median dose timing at 10, 14 and 19 weeks of age. Predictors of series completion included facility delivery (adjusted odds ratio [aOR]: 2.1; 95% CI: 1.7-2.6), household wealth (aOR: 1.9; 95% CI: 1.2-3.1 comparing the highest and lowest quintiles), Christian religion (aOR: 1.8; 95% CI: 1.3-2.5 compared with Muslim religion) and older maternal age (aOR: 1.4; 95% CI: 1.2-1.7 for 10 year units). CONCLUSIONS: Birth dose vaccination to reduce vertical and early childhood transmission of hepatitis B may overcome some of the obstacles to timely and complete HBV immunization in Cameroon. Increased awareness of HBV is needed among pregnant women and high-risk groups about vertical transmission, the importance of facility delivery and the effectiveness of prevention beginning with monovalent HBV vaccination at birth.


Assuntos
Vacinas contra Hepatite B/administração & dosagem , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Vacinação/estatística & dados numéricos , Adulto , Camarões/epidemiologia , Pré-Escolar , Estudos Transversais , Feminino , Hepatite B/prevenção & controle , Humanos , Esquemas de Imunização , Lactente , Masculino , Mães/estatística & dados numéricos
8.
J R Soc Med ; 95(9): 445-7, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12205208

RESUMO

The effects of human immunodeficiency virus (HIV) on cardiovascular autonomic function have been little investigated in African patients. We performed standard heart-rate and blood pressure tests on 75 consecutive consenting patients referred for an HIV test in Yaounde, Cameroon. 54 patients proved to be HIV-infected (30 having progressed to AIDS). Cardiovascular autonomic dysfunction was present in 8 (28%) patients with AIDS and in 1 (4%) HIV-positive patient without AIDS; no HIV-negative individuals had abnormal results. If borderline results are included, over 80% of HIV-positive patients had cardiovascular autonomic dysfunction. In HIV-infected patients, simple tests such as blood pressure responses to standing or handgrip can warn of cardiovascular autonomic dysfunction, thus signalling the need for added precautions when invasive procedures are proposed.


Assuntos
Doenças do Sistema Nervoso Autônomo/virologia , Doenças Cardiovasculares/virologia , Infecções por HIV/complicações , Adulto , Doenças do Sistema Nervoso Autônomo/etnologia , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Pressão Sanguínea/fisiologia , Camarões/etnologia , Doenças Cardiovasculares/etnologia , Doenças Cardiovasculares/fisiopatologia , Estudos Transversais , Infecções por HIV/etnologia , Infecções por HIV/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...