Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Am J Sports Med ; 45(11): 2493-2500, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28609639

RESUMO

BACKGROUND: Several radiographic parameters utilized for the diagnosis of acetabular dysplasia in adults suffer from poor reproducibility and reliability. PURPOSE: To define and validate a novel radiographic parameter (the iliofemoral line [IFL]) for the detection of frank and borderline hip dysplasia and to compare the sensitivity and specificity of this radiographic marker to those of previously validated qualitative parameters. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: A consecutive cohort of 222 adult patients (436 hips) undergoing hip preservation surgery was included. The IFL, which extends from the lateral femoral neck through the inner cortical lip of the iliac crest, intersects the femoral head in cases of dysplasia. Percent medialization of the IFL was defined as the horizontal distance of the exposed femoral head lateral to the IFL, relative to the horizontal femoral head width at the center of the femoral head. RESULTS: Percent medialization of the IFL was strongly correlated to the lateral center edge angle ( P < .0001). Values of percent medialization ranging from 15% to 22% predicted the presence of borderline hip dysplasia with a sensitivity of 62% and specificity of 89%, while values exceeding 22% predicted the presence of frank acetabular dysplasia with a sensitivity of 77% and specificity of 94%. By comparison, abnormality of the Shenton line demonstrated a sensitivity of 3.7% and specificity of 97% for the detection of borderline dysplasia and a sensitivity of 16% and specificity of 99% for the detection of frank acetabular dysplasia. Compared with the Shenton line, percent medialization of the IFL was significantly more sensitive for the detection of both borderline and frank acetabular dysplasia (both P < .0001). The intraobserver and interobserver reproducibility of the horizontal difference outside the IFL were 0.99 and 0.96, respectively. CONCLUSION: Percent medialization of the IFL is a reliable and accurate radiographic marker of frank acetabular dysplasia and, to a lesser extent, borderline dysplasia. The use of this radiographic parameter as an additional tool may enable the earlier detection of borderline and frank hip dysplasia in young adults presenting with hip pain.


Assuntos
Luxação do Quadril/diagnóstico por imagem , Radiografia/métodos , Adulto , Estudos de Coortes , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Colo do Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
3.
Hip Int ; 23(6): 565-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23813173

RESUMO

The aim of this study was to compare fixation of proximal femoral osteotomies using reverse contralateral LCP-Distal Femoral Plates (LCP-DF) with the more traditional blade plate technique. This was a retrospective review over six years of a single surgeon's practice within a tertiary orthopaedic unit. Patient demographics were collected, along with indication for surgery. Radiological outcomes, fixation failures and the need for revision surgery were recorded. Forty-six patients were identified; 23 patients in the LCP-DF plate group (7 females, 16 males. Mean age 18.3 years old) and 23 patients in the blade plate group (6 females, 17 males. Mean age 19.1 years old). The patients' presenting conditions were; 26 Perthes'; eight hip dysplasia; 11 slipped capital femoral epiphysis; one fibrous dysplasia. Osteotomy type included; 13 Double osteotomy, 11 Imhauser; 13 pure valgus; eight valgus + rotation; There was one revision for implant failure in the LCP-DF group. In the blade plate group, there were four implant failures--three requiring revision operations (p = 0.155). In the LCP-DF group the mean neck-shaft angle difference compared to the contralateral side (if normal) or 135 degrees (if abnormal) was 0.58°. In the condylar plate group the mean difference was 4.37°. The use of a contralateral LCP-DF plate in the reverse contralateral position to stabilise proximal femoral osteotomies in our cohort confers advantages over blade plate technology. We have found that the plate is stiffer, is easier to use and provides increased screw placement options over standard proximal femoral locking plates.


Assuntos
Placas Ósseas , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Osteotomia/métodos , Escorregamento das Epífises Proximais do Fêmur/cirurgia , Adolescente , Adulto , Criança , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Escorregamento das Epífises Proximais do Fêmur/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...