Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Curr Glaucoma Pract ; 17(4): 178-190, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38269268

RESUMO

Aim and background: To evaluate the ability of pattern electroretinogram (PERG) to detect improvement of retinal ganglion cell (RGC) function in glaucoma suspects (GS) after medically reducing intraocular pressure (IOP) using prostaglandin analog drops. Materials and methods: Six subjects (eight eyes) received topical IOP lowering treatment based on their clinical examination and were observed at Manhattan Eye, Ear & Throat Hospital over an average of 3.1 ± 2.2 months. During this time, participants underwent a full ophthalmologic exam and were evaluated with a Humphrey visual field analyzer (HFA) 24-2 [24-2 mean deviation (MD), 24-2 pattern standard deviation (PSD), and 24-2 visual field indices (VFI)], Diopsys NOVA PERG optimized for glaucoma [magnitude (Mag), magnitudeD (MagD), and magnitudeD/magnitude ratio (MagD/Mag ratio)] and optical coherence tomography (OCT)-derived average retinal nerve fiber layer thickness (avRNFLT) and average ganglion cell layer + inner plexiform layer (avGCL + IPL) thicknesses at baseline visit (pretreatment) and 3 months later (posttreatment). Goldman applanation tonometry was used to measure IOP at each visit. Paired sample t-tests were conducted to determine the statistical significance of the change in IOP, HFA indices, PERG parameters, and OCT thickness measurements between the two visits. Results: Lowering IOP by 22.29% resulted in a significant increase (32.98 and 15.49%) in MagD [t (7) = -3.174, 95% confidence interval (CI) = -0.53, -0.08, p = 0.016] and MagD/Mag ratio [t (7) = -3.233, 95% CI = -0.20, -0.03, p = 0.014], respectively. There was a positive percentage change for all variables of interest, however, 24-2 MD, Mag, avRNFLT, and GCL+ IPLT did not reach statistical significance. Conclusion: After reducing IOP by 22.29% for a duration of 3.1 months, the PERG parameters, MagD and MagD/Mag ratio, significantly improved by 32.98 and 15.49%, respectively. Clinical significance: Pattern electroretinogram (PERG) may be a crucial tool for clinicians to locate a window of opportunity in which degenerating yet viable RGCs could be rescued from irreversible damage. We suggest consideration of PERG as a tool in early retinal ganglion cell (RGC) dysfunction detection as well as for monitoring IOP lowering treatment. How to cite this article: Tirsi A, Gliagias V, Sheha H, et al. Retinal Ganglion Cell Functional Recovery after Intraocular Pressure Lowering Treatment Using Prostaglandin Analogs in Glaucoma Suspects: A Prospective Pilot Study. J Curr Glaucoma Pract 2023;17(4):178-190.

2.
Doc Ophthalmol ; 145(3): 221-235, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36161380

RESUMO

PURPOSE: To derive and validate structure-function models for estimating retinal ganglion cell (RGC) count using optical coherence tomography (OCT) and steady-state pattern electroretinography (ssPERG) parameters in glaucoma suspects (GS) and preperimetric glaucoma (PPG). METHODS: In this prospective cross-sectional study, 25 subjects (50 eyes) were recruited at the Manhattan Eye, Ear, and Throat Hospital. Subjects underwent comprehensive eye examinations, OCT, standard automated perimetry (SAP), and ssPERG testing. Eyes were divided into three groups based on the Global Glaucoma Staging System: healthy (N = 30), GS (N = 10), and PPG (N = 10) eyes. The combined structure-function index (CSFI), which estimates retinal ganglion cell count (eRGCCSFI) from SAP and OCT parameters, was calculated in each study subject. Two prediction formulas were derived using a generalized linear mixed model (GLMM) to predict eRGCCSFI from ssPERG parameters, age, and average retinal nerve fiber layer thickness (ARNFLT) in 30 eyes selected at random (training group). GLMM predicted values were cross-validated with the remaining 20 eyes (validation group). RESULTS: The ARNFLT, ssPERG parameters magnitude (Mag) and magnitudeD (MagD), and eRGCCSFI were significantly different among study groups (ANOVA p ≤ 0.001). Pearson correlations demonstrated significant associations among ARNFLT, ssPERG parameters, and eRGCCSFI (r2 ≥ 0.31, p < 0.001). Two GLMMs predicted eRGCCSFI from Mag (eRGCMag) and MagD (eRGCMagD), respectively, with significant equations (F(3,18), F(3,19) ≥ 58.37, R2 = 0.90, p < 0.001). eRGCMag and eRGCMagD in the validation group (R2 = 0.89) correlated with eRGCCSFI similarly to the training group. Multivariate pairwise comparisons revealed that eRGCMag and eRGCMagD distinguished between healthy, GS, and PPG eyes (p ≤ 0.035), whereas independent Mag, MagD, and ARNFLT measures did not distinguish between GS and PPG eyes. CONCLUSION: This pilot study offers the first combined structure-function models for estimating RGC count using ssPERG parameters. RGC counts estimated with these models were generalizable, strongly associated with CSFI estimates, and performed better than individual ssPERG and OCT measures in distinguishing healthy, GS, and PPG eyes.


Assuntos
Glaucoma , Hipertensão Ocular , Humanos , Células Ganglionares da Retina/fisiologia , Tomografia de Coerência Óptica/métodos , Projetos Piloto , Eletrorretinografia/métodos , Fibras Nervosas , Estudos Transversais , Estudos Prospectivos , Campos Visuais , Contagem de Células , Glaucoma/diagnóstico , Testes de Campo Visual , Hipertensão Ocular/diagnóstico , Pressão Intraocular
3.
Doc Ophthalmol ; 145(1): 11-25, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35377032

RESUMO

PURPOSE: To estimate retinal ganglion cell (RGC) count in glaucoma suspects (GS) and ascertain its relationships with steady-state pattern electroretinography (ssPERG) parameters. METHODS: In this prospective cross-sectional study, 22 subjects (44 eyes) were recruited at the Manhattan Eye, Ear, and Throat Hospital. Subjects underwent complete eye examinations, optical coherence tomography, standard automated perimetry, and ssPERG testing. Eyes were divided into two groups based upon clinical data: healthy subjects and GS. RGC count was estimated using the combined structure-function index. RESULTS: Estimated RGC count, average retinal nerve fiber layer thickness (ARNFLT), and average ganglion cell layer and inner plexiform layer thickness (GCIPLT) were reduced in GS eyes (p ≤ 0.001 for all parameters). Pearson correlations revealed that ssPERG magnitude and magnitudeD correlated with ARNFLT (r ≥ 0.53, p < 0.001), GCIPLT (r > 0.38, p < 0.011), and estimated RGC count (r > 0.46, p < 0.002). Six mediation analyses revealed that estimated RGC count mediated the relationships among ssPERG parameters, ARNFLT, and GCIPLT. CONCLUSION: Steady-state PERG parameters demonstrated linear correlations with estimated RGC count. The associations among ssPERG parameters and structural measures were mediated by estimated RGC count.


Assuntos
Glaucoma , Hipertensão Ocular , Estudos Transversais , Eletrorretinografia , Glaucoma/diagnóstico , Humanos , Hipertensão Ocular/diagnóstico , Estudos Prospectivos , Células Ganglionares da Retina/fisiologia , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual
4.
J Ophthalmol ; 2021: 8025337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34845426

RESUMO

PURPOSE: We examined the relationships between pattern electroretinogram and optical coherence tomography derived optic nerve head measurements, after controlling for disc area. METHODS: Thirty-two eyes from 20 subjects with preperimetric glaucoma underwent pattern electroretinogram and optical coherence tomography. Pattern electroretinogram parameters (Magnitude, MagnitudeD, and MagnitudeD/Magnitude ratio) and optic nerve head measurements (rim area, average cup to disc ratio, vertical cup to disc ratio, cup volume, retinal nerve fiber layer thickness sectors, and Bruch's membrane opening-minimum rim width thickness sectors) were analyzed after controlling for disc area. RESULTS: Magnitude and MagnitudeD were significantly associated with rim area (r ≥ 0.503, p ≤ 0.004). All pattern electroretinogram parameters significantly correlated with Bruch's membrane opening-minimum rim width sectors-temporal superior and nasal inferior (r = 0.400, p=0.039)-and retinal nerve fiber layer sectors-superior, nasal superior, and inferior (r ≥ 0.428, p ≤ 0.026). Magnitude and MagnitudeD explained an additional 26.8% and 25.2% of variance in rim area (B = 0.174 (95% CI: 0.065, 0.283), p=0.003, and B = 0.160 (95% CI: 0.056, 0.265), p=0.004), respectively. MagnitudeD and MagnitudeD/Magnitude ratio explained an additional 13.4% and 12.8% of the variance in Bruch's membrane opening-minimum rim width global (B = 38.921 [95% CI: 3.872, 73.970], p=0.031, and B = 129.024 (95% CI: 9.589, 248.460), p=0.035), respectively. All Bruch's membrane opening-minimum rim width sectors and retinal nerve fiber layer sectors (nasal superior, nasal inferior, and inferior) were significantly correlated with rim area (r ≥ 0.389, p ≤ 0.045). CONCLUSION: PERG abnormalities can predict rim area loss in preperimetric glaucoma after controlling for disc area. We recommend controlling for disc area to increase diagnostic accuracy in early glaucoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...