Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 596
Filtrar
2.
Braz J Biol ; 84: e278769, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38422292

RESUMO

Round cell tumors are common cutaneous lesions in dogs, with increased occurrence percentages among different skin tumors. This study aimed to investigate the frequency as well as gross and pathological characteristics of round cell tumors in natural cases of tumorous dogs in relation to breed, sex, and age. Moreover, it aimed to evaluate the immunohistochemical expression of a panel of immunohistochemical stains, including vimentin, E-cadherin, and cluster of differentiation (CD45) as an adjunct technique for the differential diagnosis of cutaneous round cell neoplasm. Data were collected from 64 dogs of both sexes (36 females and 28 males), various breeds, and different ages (8 months to 7 years). The histopathological nature of neoplastic growth was reported, and neoplasm prevalence was classified using age, sex, breed, and site on the body. We observed 48 cases of transmissible venereal tumors, 12 cutaneous histiocytomas, and 4 histiocytic sarcoma. Immunohistochemical characterization revealed an intense positive immunoreactivity for vimentin in transmissible venereal tumor cells and moderate positive immunoreactivity for E-cadherin and CD45 in cutaneous histiocytoma and histiocytic sarcoma cells. In conclusion, the canine transmissible venereal tumor was the most frequent form of round cell tumor; thus, a definitive cutaneous neoplasm diagnosis should be based on histopathological morphology and immunohistochemical findings.


Assuntos
Sarcoma Histiocítico , Neoplasias Cutâneas , Tumores Venéreos Veterinários , Feminino , Masculino , Cães , Animais , Sarcoma Histiocítico/diagnóstico , Sarcoma Histiocítico/veterinária , Vimentina , Tumores Venéreos Veterinários/patologia , Imuno-Histoquímica , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/veterinária , Neoplasias Cutâneas/patologia , Caderinas/metabolismo
3.
Georgian Med News ; (338): 69-73, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37419474

RESUMO

Blastocystis parasites are common intestinal parasites found in various hosts, including humans. This study involved two groups: the patient group, consisting of 220 samples, and the control group, consisting of 100 samples. The participants' age range was 4-40 years, and the samples were obtained from Al-Kadhimiya Teaching Hospital and Al-Shaheed Mohammed Baqir Al-Hakeem Hospital in Baghdad, Iraq. Stool samples were examined under a light microscope using Lugal's Iodine Stain and direct wet smears. The age group did not show a significant difference (P≥0.05) in patients with diarrhea infected with the Blastocystis hominis parasite compared to the control group. Furthermore, males had a higher infection rate (58.00%) compared to females (42.00%), and this rate was statistically significant (P≤0.05). The aim of this study was to evaluate the effect of Blastocystis hominis infection on the levels of certain immunological parameters. The results of the ELISA technique for immunological examinations revealed a significant increase (P≤0.01) in the levels of IL-10 and IL-17 in the serum of patients with diarrhea infected with the Blastocystis hominis parasite compared to the control group. The immunological tests also showed a significant increase (P≤0.01) in IgG, IgM antibodies, and IgA levels in patients with diarrhea infected with Blastocystis hominis parasite compared to the control group. These findings suggest that Blastocystis infection may influence immunological responses.


Assuntos
Infecções por Blastocystis , Blastocystis hominis , Masculino , Feminino , Humanos , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Infecções por Blastocystis/complicações , Infecções por Blastocystis/parasitologia , Estudos Transversais , Fezes/parasitologia , Diarreia
5.
Front Microbiol ; 14: 1130018, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37152725

RESUMO

The suomilide and the banyasides are highly modified and functionalized non-ribosomal peptides produced by cyanobacteria of the order Nostocales. These compound classes share several substructures, including a complex azabicyclononane core, which was previously assumed to be derived from the amino acid tyrosine. In our study we were able to isolate and determine the structures of four suomilides, named suomilide B - E (1-4). The compounds differ from the previously isolated suomilide A by the functionalization of the glycosyl group. Compounds 1-4 were assayed for anti-proliferative, anti-biofilm and anti-bacterial activities, but no significant activity was detected. The sequenced genome of the producer organism Nostoc sp. KVJ20 enabled us to propose a biosynthetic gene cluster for suomilides. Our findings indicated that the azabicyclononane core of the suomilides is derived from prephenate and is most likely incorporated by a proline specific non-ribosomal peptide synthetase-unit.

7.
Radiography (Lond) ; 28(1): 61-67, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34404578

RESUMO

INTRODUCTION: Deep learning approaches have shown high diagnostic performance in image classifications, such as differentiation of malignant tumors and calcified coronary plaque. However, it is unknown whether deep learning is useful for characterizing coronary plaques without the presence of calcification using coronary computed tomography angiography (CCTA). The purpose of this study was to compare the diagnostic performance of deep learning with a convolutional neural network (CNN) with that of radiologists in the estimation of coronary plaques. METHODS: We retrospectively enrolled 178 patients (191 coronary plaques) who had undergone CCTA and integrated backscatter intravascular ultrasonography (IB-IVUS) studies. IB-IVUS diagnosed 81 fibrous and 110 fatty or fibro-fatty plaques. We manually captured vascular short-axis images of the coronary plaques as Portable Network Graphics (PNG) images (150 × 150 pixels). The display window level and width were 100 and 700 Hounsfield units (HU), respectively. The deep-learning system (CNN; GoogleNet Inception v3) was trained on 153 plaques; its performance was tested on 38 plaques. The area under the curve (AUC) obtained by receiver operating characteristic analysis of the deep learning system and by two board-certified radiologists was compared. RESULTS: With the CNN, the AUC and the 95% confidence interval were 0.83 and 0.69-0.96, respectively; for radiologist 1 they were 0.61 and 0.42-0.80; for radiologist 2 they were 0.68 and 0.51-0.86, respectively. The AUC for CNN was significantly higher than for radiologists 1 (p = 0.04); for radiologist 2 it was not significantly different (p = 0.22). CONCLUSION: DL-CNN performed comparably to radiologists for discrimination between fatty and fibro-fatty plaque on CCTA images. IMPLICATIONS FOR PRACTICE: The diagnostic performance of the CNN and of two radiologists in the assessment of 191 ROIs on CT images of coronary plaques whose type corresponded with their IB-IVUS characterization was comparable.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Redes Neurais de Computação , Placa Aterosclerótica/diagnóstico por imagem , Estudos Retrospectivos
8.
AJNR Am J Neuroradiol ; 41(2): 231-237, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31879332

RESUMO

BACKGROUND AND PURPOSE: Deep brain stimulation electrodes induce massive artifacts on CT images, deteriorating the diagnostic value of examinations. We aimed to investigate the usefulness and potential limitations of a single-energy metal artifact reduction algorithm in head CT performed in patients with implanted deep brain stimulation devices. MATERIALS AND METHODS: Thirty-four patients with deep brain stimulation (bilateral, n = 28) who underwent head CT on a 320-detector row scanner and whose images were reconstructed with and without single-energy metal artifact reduction at the examinations were retrospectively included. The severity of artifacts around electrodes was assessed objectively using SDs and an artifact index. Two radiologists subjectively evaluated the severity of artifacts from electrodes, the visibility of electrode localization and surrounding structures, and overall diagnostic confidence on 4-point scales. Background image quality (GM-WM contrast and image noise) was subjectively and objectively assessed. The presence and location of artifacts newly produced by single-energy metal artifact reduction were analyzed. RESULTS: Single-energy metal artifact reduction provided lower objective and subjective metal artifacts and improved visualization of electrode localization and surrounding structures and diagnostic confidence compared with non-single-energy metal artifact reduction images, with statistical significance (all, P < .01). No significant differences were observed in GM-WM contrast and image noise (all, P ≥ .11). The new artifacts from single-energy metal artifact reduction were prominently observed in patients with bilateral deep brain stimulation at high convexity, possibly induced by deep brain stimulation leads placed under the parietal scalp. CONCLUSIONS: Single-energy metal artifact reduction substantially reduces the metal artifacts from deep brain stimulation electrodes and improves the visibility of intracranial structures without affecting background image quality. However, non-single-energy metal artifact reduction images should be simultaneously reviewed to accurately assess the entire intracranial area, particularly in patients with bilateral deep brain stimulation.


Assuntos
Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Estimulação Encefálica Profunda , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Clin Radiol ; 74(2): 167.e1-167.e7, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30471748

RESUMO

AIM: To compare the performance of machine learning using multiparametric magnetic resonance imaging (mp-MRI) and positron-emission tomography (PET) to distinguish between uterine sarcoma and leiomyoma. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board and informed consent was waived. Sixty-seven consecutive patients with uterine sarcoma or leiomyoma who underwent pelvic 3 T MRI and PET were included. Of 67 patients, 11 had uterine sarcomas and 56 had leiomyomas. Seven different parameters were measured in the tumours, from T2-weighted, T1-weighted, contrast-enhanced, and diffusion-weighted MRI, and PET. The areas under the receiver operating characteristic curves (AUC) with a leave-one-out cross-validation were used to compare the diagnostic performances of the univariate and multivariate logistic regression (LR) model with those of two board-certified radiologists. RESULTS: The AUCs of the univariate models using MRI parameters (0.68-0.8) were inferior to that of the maximum standardised uptake value (SUVmax) of PET (0.85); however, the AUC of the multivariate LR model (0.92) was superior to that of SUVmax, and comparable to that of the board-certified radiologists (0.97 and 0.89). CONCLUSION: The diagnostic performance of the machine learning using mp-MRI was superior to PET and comparable to that of experienced radiologists.


Assuntos
Fluordesoxiglucose F18 , Leiomioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Sarcoma/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Útero/diagnóstico por imagem , Adulto Jovem
10.
Clin Radiol ; 73(12): 1058.e21-1058.e29, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30237063

RESUMO

AIM: To compare the image quality and radiation dose of reduced iodine dose dual-layer detector (DL) computed tomography (CT) with those of a conventional 120 kVp protocol for chest-abdomen-pelvis CT (CAP-CT). MATERIALS AND METHODS: Forty patients with renal dysfunction (estimated glomerular filtrating ratio <45 ml/min/1.73 m2) underwent reduced iodine dose CAP-CT (120 kVp, 200 mg iodine/kg) on DLCT. Virtual monochromatic images (VMI) at 40-70 keV (5 keV interval) were reconstructed retrospectively. Forty matched patients who underwent conventional CAP-CT (120 kVp, 600 mg iodine/kg, iterative reconstruction) were included as controls. The size-specific dose estimate (SSDE), image noise, CT attenuation, and contrast-to-noise ratio (CNR) were compared between the protocols. Two radiologists rated image contrast, image noise, streak artefact, and diagnostic confidence on a five-point scale. RESULTS: The SSDE of the DLCT group was approximately 20% lower than that of the 120 kVp group (15.4±1.9 versus 19.4±2.3 mGy, p<0.01). DLCT-VMI provided almost constant image noise throughout the range of energies (differences of ≤13%), with the noise being equivalent or lower than 120 kVp in the abdomen. CT attenuation and CNR gradually increased as the energy decreased, with values comparable to 120 kVp being attained at around 45-50 keV. Although streak artefact was accentuated at 40-50 keV (p<0.01), the highest scores for diagnostic confidence were assigned at 40 and 45 keV, both of which were equivalent to 120 kVp (p=1.0). CONCLUSION: For CAP-CT with a one-third iodine dose, DLCT-VMI at 40-45 keV allows for a 20% reduction in radiation dose, while preserving image quality comparable to that of conventional 120 kVp protocol.


Assuntos
Abdome/diagnóstico por imagem , Pelve/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Insuficiência Renal Crônica/diagnóstico por imagem , Tórax/diagnóstico por imagem , Abdome/efeitos da radiação , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Pelve/efeitos da radiação , Doses de Radiação , Intensificação de Imagem Radiográfica , Insuficiência Renal Crônica/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Tórax/efeitos da radiação
11.
Eur J Pain ; 22(10): 1757-1766, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29934985

RESUMO

BACKGROUND: Accumulating evidence indicates that knee pain gives rise to sensory and motor alterations, however, whether different profile of knee pain causes different alterations has not been investigated. The purpose of this experimental study is to clarify characteristics of medial and lateral knee pain and its potential for modulating sensory and motor function in humans. METHODS: Fourteen healthy men were included. Medial knee pain (MP) was induced by injection of hypertonic saline (0.5 mL) into the tibial insertion of the medial collateral ligament. For comparison, lateral knee pain (LP) was induced by injection of hypertonic saline identically into the iliotibial tract. Isotonic saline was injected contralaterally as control. Pain intensity was assessed on a continuous electronic visual analogue scale (VAS). Before, during and after the painful state, pressure pain thresholds from the knee (PPTs), maximal isometric muscle strength of the quadriceps and grip power were assessed bilaterally. RESULTS: MP demonstrated significantly higher VAS scores than LP and compared with control. PPTs decreased on medial and lateral knee in MP but only on the lateral knee in LP. Quadriceps muscle strength and grip power reduced bilaterally in both models, however, MP caused significantly greater reduction of ipsilateral quadriceps strength compared with LP. CONCLUSION: Medial knee pain has a greater impact on deep tissue hyperalgesia and reduction of the muscle strength compared with lateral knee pain. This is a novel finding that should be taken into consideration in a treatment strategy for painful knee patients. SIGNIFICANCE: The experimental medial knee pain model demonstrated higher pain intensity, more localized pain distribution, widespread deep tissue hyperalgesia and more severe inhibition of muscle strength compared with the lateral knee pain model.


Assuntos
Artralgia/etiologia , Artralgia/fisiopatologia , Hiperalgesia/etiologia , Articulação do Joelho , Força Muscular/fisiologia , Adulto , Método Duplo-Cego , Humanos , Hiperalgesia/fisiopatologia , Masculino , Medição da Dor , Limiar da Dor/fisiologia , Pressão , Músculo Quadríceps/fisiopatologia , Solução Salina Hipertônica
12.
J Periodontal Res ; 53(2): 188-199, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29063599

RESUMO

BACKGROUND AND OBJECTIVE: Diagnosis is a crucial step in periodontal treatment. The aim of this study was to evaluate the effectiveness of optical coherence tomography (OCT) for observation and determination of periodontal tissue profiles in vivo. MATERIAL AND METHODS: In experiment 1, refractive indices of purified water, porcine gingiva and human gingiva at 1330 nm were determined for the analysis of OCT images of periodontal tissues. In experiment 2, OCT examination was performed in the midlabial apico-coronal plane of mandibular anteriors in 30 Asian volunteers with healthy gingiva. Sulcus depth was measured on intra-oral photographs taken during probing. In the OCT images, the gingival, epithelial and connective tissue thickness, and the position of alveolar bone crest were determined and finally, the biologic width was measured. RESULTS: Refractive indices of purified water, porcine gingiva and human gingiva were 1.335, 1.393 and 1.397, respectively. Cross-sectional images of gingival epithelium, connective tissue and alveolar bone were depicted in real-time. The sulcular and junctional epithelium could be visualized occasionally. Laser penetration and reflection were limited to a certain depth with an approximate maximal imaging depth capability of 1.5 mm and OCT images of the periodontal structure were not clear in some cases. The average maximal thickness of gingiva and epithelium and biologic width at the mandibular anteriors were 1.06 ± 0.21, 0.49 ± 0.15 and 2.09 ± 0.60 mm, respectively. CONCLUSION: OCT has promise for non-invasive observation of the periodontal tissue profile in detail and measurement of internal periodontal structures including biologic width in the anterior region.


Assuntos
Diagnóstico por Imagem/métodos , Periodonto/diagnóstico por imagem , Periodonto/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Processo Alveolar/anatomia & histologia , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/patologia , Animais , Tecido Conjuntivo/anatomia & histologia , Tecido Conjuntivo/diagnóstico por imagem , Tecido Conjuntivo/patologia , Diagnóstico por Imagem/instrumentação , Inserção Epitelial/anatomia & histologia , Inserção Epitelial/diagnóstico por imagem , Inserção Epitelial/patologia , Feminino , Gengiva/anatomia & histologia , Gengiva/diagnóstico por imagem , Gengiva/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Incisivo/anatomia & histologia , Incisivo/diagnóstico por imagem , Incisivo/patologia , Lasers , Masculino , Mandíbula/anatomia & histologia , Mandíbula/diagnóstico por imagem , Mandíbula/patologia , Mucosa/diagnóstico por imagem , Mucosa/patologia , Bolsa Periodontal/diagnóstico por imagem , Bolsa Periodontal/patologia , Periodonto/anatomia & histologia , Fotografia Dentária , Reprodutibilidade dos Testes , Suínos , Tomografia de Coerência Óptica/instrumentação , Adulto Jovem
13.
Clin Radiol ; 73(2): 217.e7-217.e16, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29029768

RESUMO

AIM: To perform an intra-individual investigation of the usefulness of a contrast medium (CM) and radiation dose-reduction protocol using single-source computed tomography (CT) combined with 100 kVp and sinogram-affirmed iterative reconstruction (SAFIRE) for whole-body CT (WBCT; chest-abdomen-pelvis CT) in oncology patients. MATERIALS AND METHODS: Forty-three oncology patients who had undergone WBCT under both 120 and 100 kVp protocols at different time points (mean interscan intervals: 98 days) were included retrospectively. The CM doses for the 120 and 100 kVp protocols were 600 and 480 mg iodine/kg, respectively; 120 kVp images were reconstructed with filtered back-projection (FBP), whereas 100 kVp images were reconstructed with FBP (100 kVp-F) and the SAFIRE (100 kVp-S). The size-specific dose estimate (SSDE), iodine load and image quality of each protocol were compared. RESULTS: The SSDE and iodine load of 100 kVp protocol were 34% and 21%, respectively, lower than of 120 kVp protocol (SSDE: 10.6±1.1 versus 16.1±1.8 mGy; iodine load: 24.8±4versus 31.5±5.5 g iodine, p<0.01). Contrast enhancement, objective image noise, contrast-to-noise-ratio, and visual score of 100 kVp-S were similar to or better than of 120 kVp protocol. CONCLUSION: Compared with the 120 kVp protocol, the combined use of 100 kVp and SAFIRE in WBCT for oncology assessment with an SSCT facilitated substantial reduction in the CM and radiation dose while maintaining image quality.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Iohexol , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
15.
Nat Mater ; 16(2): 208-213, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27643731

RESUMO

Electronic defect states at material interfaces provide highly deleterious sources of noise in solid-state nanostructures, and even a single trapped charge can qualitatively alter the properties of short one-dimensional nanowire field-effect transistors (FET) and quantum bit (qubit) devices. Understanding the dynamics of trapped charge is thus essential for future nanotechnologies, but their direct detection and manipulation is rather challenging. Here, a transistor-based set-up is used to create and probe individual electronic defect states that can be coherently driven with microwave (MW) pulses. Strikingly, we resolve a large number of very high quality (Q ∼ 1 × 105) resonances in the transistor current as a function of MW frequency and demonstrate both long decoherence times (∼1 µs-40 µs) and coherent control of the defect-induced dynamics. Efficiently characterizing over 800 individually addressable resonances across two separate defect-hosting materials, we propose that their properties are consistent with weakly driven two-level systems.

16.
Iran J Vet Res ; 17(2): 98-105, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27822234

RESUMO

This study was conducted to evaluate the efficacy of oral administration of fenbendazole (20 mg/kg body weight) prior to and after experimental infection of immunosuppressed rabbits with Encephalitozoon cuniculi. A total of thirty rabbits were divided into five groups: NN (non-immunosuppressed; non-infected), IN (immunosuppressed; non-infected), IPI (immunosuppressed; protected-infected), ITI (immunosuppressed; treated-infected), and II (immunosuppressed; infected) groups. Fenbendazole was administered as a prophylactic for seven successive days before infection with E. cuniculi and as a treatment for four weeks initiated on the 28th day post-challenge (PC). Experimental rabbits were infected with intraperitoneal injection of 2 × 105E. cuniculi spores. Parameters evaluated were body weight, detection of spores in urine, serum antibody assay, hematological, biochemical and histopathological changes. The IPI and ITI groups showed a significant better final bwt than the II group. Spores were detected in urine of all infected rabbits from the 28th day PC until the end of the study. The IPI group showed the least values of antibodies (IgG) compared to the ITI and II groups. Concerning histopathological changes, the intensity of the lesions was marked particularly in the II rabbits and to a lesser extent in the ITI rabbits. Noticeable improvement was found in the IPI rabbits. It could be concluded that fenbendazole was effective to some extent in protection of rabbits against E. cuniculi infection, while when administered as a therapeutic no significant effects were observed.

17.
AJNR Am J Neuroradiol ; 37(9): 1594-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27079368

RESUMO

BACKGROUND AND PURPOSE: Reversible cerebral vasoconstriction syndrome is characterized by thunderclap headache and diffuse segmental vasoconstriction that resolves spontaneously within 3 months. Previous reports have proposed that vasoconstriction first involves small distal arteries and then progresses toward major vessels at the time of thunderclap headache remission. The purpose of this study was to confirm centripetal propagation of vasoconstriction on MRA at the time of thunderclap headache remission compared with MRA at the time of reversible cerebral vasoconstriction syndrome onset. MATERIALS AND METHODS: Of the 39 patients diagnosed with reversible cerebral vasoconstriction syndrome at our hospital during the study period, participants comprised the 16 patients who underwent MR imaging, including MRA, within 72 hours of reversible cerebral vasoconstriction syndrome onset (initial MRA) and within 48 hours of thunderclap headache remission. RESULTS: In 14 of the 16 patients (87.5%), centripetal propagation of vasoconstriction occurred from the initial MRA to remission of thunderclap headache, with typical segmental vasoconstriction of major vessels. These mainly involved the M1 portion of the MCA (10 cases), P1 portion of the posterior cerebral artery (10 cases), and A1 portion of the anterior cerebral artery (5 cases). CONCLUSIONS: This study found evidence of centripetal propagation of vasoconstriction on MRA obtained at the time of thunderclap headache remission, compared with MRA obtained at the time of reversible cerebral vasoconstriction syndrome onset. If clinicians remain unsure of the diagnosis during early-stage reversible cerebral vasoconstriction syndrome, this time point represents the best opportunity to diagnose reversible cerebral vasoconstriction syndrome with confidence.


Assuntos
Transtornos da Cefaleia Primários/diagnóstico por imagem , Vasoconstrição , Adulto , Artéria Cerebral Anterior/diagnóstico por imagem , Artéria Cerebral Anterior/fisiopatologia , Feminino , Transtornos da Cefaleia Primários/fisiopatologia , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Posterior/diagnóstico por imagem , Artéria Cerebral Posterior/fisiopatologia , Síndrome
18.
J Periodontal Res ; 51(1): 77-85, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26031712

RESUMO

BACKGROUND AND OBJECTIVE: Fibroblast growth factor-2 (FGF-2) regulates the proliferation and differentiation of osteogenic cells, resulting in the promotion of bone formation. Biodegradable gelatin sponges incorporating ß-tricalcium phosphate (ß-TCP) have been reported as a scaffold, which has the ability to control growth factor release, offering sufficient mechanical strength and efficient migration of mesenchymal cells. In this study, we evaluated the effects of the combined use of recombinant human FGF-2 (rhFGF-2) and gelatin/ß-TCP sponge on ridge augmentation in dogs. MATERIAL AND METHODS: Six male beagle dogs were used in this study. Twelve wk after tooth extraction, bilateral 10 × 5 mm (width × depth) saddle-type defects were created 3 mm apart from the mesial side of the maxillary canine. At the experimental sites, the defects were filled with gelatin/ß-TCP sponge infiltrated with 0.3% rhFGF-2, whereas gelatin/ß-TCP sponge infiltrated with saline was applied to the control sites. Eight wk after surgery, qualitative and quantitative analyses were performed. RESULTS: There were no signs of clinical inflammation at 8 wk after surgery. Histometric measurements revealed that new bone height at the experimental sites (2.98 ± 0.65 mm) was significantly greater than that at the control sites (1.56 ± 0.66 mm; p = 0.004). The total tissue height was greater at the experimental sites (6.62 ± 0.66 mm) than that at the control sites (5.95 ± 0.74 mm), although there was no statistical significant difference (p = 0.051). Cast model measurements revealed that the residual defect height at the experimental sites (2.31 ± 0.50 mm) was significantly smaller than that at the control sites (3.51 ± 0.78 mm; p = 0.012). CONCLUSION: The combined use of rhFGF-2 and gelatin/ß-TCP sponge promotes ridge augmentation in canine saddle-type bone defects.


Assuntos
Fator 2 de Crescimento de Fibroblastos/uso terapêutico , Animais , Regeneração Óssea , Fosfatos de Cálcio , Cães , Gelatina , Humanos , Masculino , Osteogênese
19.
AJNR Am J Neuroradiol ; 36(9): E64, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26185327
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...