Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
PLoS One ; 19(7): e0301919, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38968191

RESUMO

INTRODUCTION: Brain positron emission tomography/computed tomography (PET/CT) scans are useful for identifying the cause of dementia by evaluating glucose metabolism in the brain with F-18-fluorodeoxyglucose or Aß deposition with F-18-florbetaben. However, since imaging time ranges from 10 to 30 minutes, movements during the examination might result in image artifacts, which interfere with diagnosis. To solve this problem, data-driven brain motion correction (DDBMC) techniques are capable of performing motion corrected reconstruction using highly accurate motion estimates with high temporal resolution. In this study, we investigated the effectiveness of DDBMC techniques on PET/CT images using a Hoffman phantom, involving continuous rotational and tilting motion, each expanded up to approximately 20 degrees. MATERIALS AND METHODS: Listmode imaging was performed using a Hoffman phantom that reproduced rotational and tilting motions of the head. Brain motion correction processing was performed on the obtained data. Reconstructed images with and without brain motion correction processing were compared. Visual evaluations by a nuclear medicine specialist and quantitative parameters of images with correction and reference still images were compared. RESULTS: Normalized Mean Squared Error (NMSE) results demonstrated the effectiveness of DDBMC in compensating for rotational and tilting motions during PET imaging. In Cases 1 and 2 involving rotational motion, NMSE decreased from 0.15-0.2 to approximately 0.01 with DDBMC, indicating a substantial reduction in differences from the reference image across various brain regions. In the Structural Similarity Index (SSIM), DDBMC improved it to above 0.96 Contrast assessment revealed notable improvements with DDBMC. In continuous rotational motion, % contrast increased from 42.4% to 73.5%, In tilting motion, % contrast increased from 52.3% to 64.5%, eliminating significant differences from the static reference image. These findings underscore the efficacy of DDBMC in enhancing image contrast and minimizing motion induced variations across different motion scenarios. CONCLUSIONS: DDBMC processing can effectively compensate for continuous rotational and tilting motion of the head during PET, with motion angles of approximately 20 degrees. However, a significant limitation of this study is the exclusive validation of the proposed method using a Hoffman phantom; its applicability to the human brain has not been investigated. Further research involving human subjects is necessary to assess the generalizability and reliability of the presented motion correction technique in real clinical scenarios.


Assuntos
Encéfalo , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Humanos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Tomografia por Emissão de Pósitrons/métodos , Movimento (Física) , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18
2.
Radiol Case Rep ; 19(2): 581-585, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38074427

RESUMO

Using postmortem computed tomography (CT) images, we achieved personal identification of a body using transposed teeth and dental treatment marks. Transposition of teeth is a rare malpositioning anomaly. CT images can clarify the malpositioning of the teeth's roots, which is difficult to discern from gross observation of the dentition. Because dental hygiene has reduced the incidence of caries in recent years, it might be difficult to use treatment marks for personal identification in the future. Transposed teeth, although rare, provide an important clue to personal identification.

3.
Tohoku J Exp Med ; 260(2): 141-147, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-36990743

RESUMO

Positron emission tomography (PET)/computed tomography (CT) has improved sensitivity and resolution using silicon photomultiplier as a photosensor. Previously, only a fixed setting was available for the shooting time of 1 bed, but now, the shooting time can be changed for each bed. Time can be shortened or extended depending on the target area. A few studies reported on image reconstruction conditions for head and neck cancer in whole-body PET/CT examinations. Thus, this study aimed to optimize the imaging conditions of the head and neck region during whole-body imaging. A cylindrical acrylic container with a 200 mm diameter was used to simulate the head and neck area using a PET/CT system equipped with a semiconductor detector. Spheres of 6-30 mm in diameter were enclosed in the 200 mm diameter cylindrical acrylic vessel. Radioactivity in 18F solution (Hot:BG ratio 4:1) was enclosed in a phantom following the Japanese Society of Nuclear Medicine (JSNM) guidelines. Background radioactivity concentration was 2.53 kBq/mL. List mode acquisition of 1,800 s was collected at 60-1,800 s with the field of view of 700 mm and 350 mm. The image was reconstructed by resizing the matrix to 128 × 128, 192 × 192, 256 × 256, and 384 × 384, respectively. The imaging time per bed in the head and neck should be at least 180 s, and the reconstruction conditions should be a field of view (FOV) of 350 mm, matrix sizes of ≥ 192, and a Bayesian penalized likelihood (BPL) reconstruction with a ß-value of 200. This allows detection of > 70% of the 8-mm spheres in the images.


Assuntos
Neoplasias de Cabeça e Pescoço , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Teorema de Bayes , Processamento de Imagem Assistida por Computador/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18
4.
Alzheimers Res Ther ; 15(1): 15, 2023 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-36635728

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a strong risk factor for Alzheimer's disease (AD) independent of ischemic stroke. However, the clinicopathological impact of AF on the severity of AD has not been well elucidated. We aimed to investigate the clinical differences between dementia patients with AF and those without AF by means of imaging data. METHODS: Following approval from the institutional ethics committee, patients with newly diagnosed AD or amnestic mild cognitive impairment (aMCI) were retrospectively screened (n = 170, 79.5 ± 7.4 years old). Cognitive function was assessed using the Mini-Mental State Examination (MMSE). Based on the MRI data, the cerebral volume, cerebral microbleeds (CMBs), periventricular white matter lesions (WMLs), and deep WMLs were evaluated. The regional cerebral blood flow (rCBF) was measured using 123I-IMP SPECT. RESULTS: Of the patients, 14 (8.2%) and 156 (91.8%) had AF (AF group) and sinus rhythm (SR group), respectively. The AF group had significantly lower MMSE scores than the SR group (average [standard deviation (SD)]: 19.4 [4.4] and 22.0 [4.4], respectively; p = 0.0347). Cerebral volume and CMBs did not differ between the two groups. The periventricular WMLs, but not the deep WMLs, were significantly larger in the AF group than in the SR group (mean [SD] mL: 6.85 [3.78] and 4.37 [3.21], respectively; p = 0.0070). However, there was no significant difference in rCBF in the areas related to AD pathology between the two groups. CONCLUSION: AD and aMCI patients with AF showed worse cognitive decline along with larger periventricular WMLs compared to those with SR, although the reduction of rCBF was not different between patients with AF and SR. The white matter lesions may be a more important pathology than the impairment of cerebral blood flow in dementia patients with AF. A larger study is needed to confirm our findings in the future.


Assuntos
Doença de Alzheimer , Fibrilação Atrial , Disfunção Cognitiva , Humanos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/complicações , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Encéfalo/patologia , Estudos Retrospectivos , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/patologia , Imageamento por Ressonância Magnética/métodos
5.
Tohoku J Exp Med ; 257(4): 327-332, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35691914

RESUMO

The liver is an organ that is frequently injured by blunt trauma. In clinical medicine, contrast-enhanced computed tomography (CT) is useful for diagnosing liver damage. However, detection of liver injury is difficult with postmortem CT (PMCT) that does not use contrast media. This study aims to identify findings that are useful for diagnosing liver injury with PMCT. This study included 97 high-energy trauma cases that underwent both PMCT without contrast and forensic autopsy between July 2009 and November 2020. PMCT findings in and around the liver in cases of liver injury were collected. The diagnostic accuracy of each finding was calculated. Of 97 cases, 62 had liver injury on autopsy. PMCT detected hepatic surface gas in 31 cases, intrahepatic focal gas in 19 cases, high-density fluid accumulation around the liver in 12 cases, and fracture of a right lower (9th-12th) rib in 48 cases. Abnormal PMCT findings in and around the liver had insufficient diagnostic sensitivity, ranging from 19.4% to 38.7%. By contrast, the finding of a right lower rib fracture was more sensitive for suspected liver injury. Our results indicate that abdominal liver findings (hepatic surface gas, intrahepatic focal gas, and high-density fluid accumulation around the liver) are of limited utility for the diagnosis of liver injury, whereas a right lower rib fracture is a useful indirect finding.


Assuntos
Fraturas das Costelas , Autopsia , Humanos , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
Oral Radiol ; 38(4): 540-549, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35061164

RESUMO

OBJECTIVE: The higher sensitivity of the new-generation positron emission tomography/computed tomography (PET/CT) with silicon photomultiplier (SiPM) may increase false-positive rates in detecting metastatic lymph nodes (LNs). This study aimed to clarify the usefulness of the SiPM PET scanner in diagnosing LN metastasis of oral squamous cell carcinoma (SCC). METHODS: We retrospectively reviewed consecutive F-18 fluorodeoxyglucose PET/CT images of 39 SCC patients using SiPM PET and 31 SCC patients using non-SiPM PET. We measured the maximum standardized uptake value (SUVmax) of the LNs on PET images and maximum short-axis diameter on transverse CT images. RESULTS: The sensitivity and specificity of SiPM PET were 86.2% and 95.6%, respectively (cut-off SUVmax, 4.6). The area under the curve (AUC) of SiPM PET (0.977; 95% confidence interval [CI], 0.958-0.995) was significantly higher than that of non-SiPM PET (0.825; 95% CI 0.717-0.934) (P < 0.01). In a size-limited analysis of diameter, the AUC of SiPM PET (≥ 0.96 for all diameters) was significantly higher than that of non-SiPM PET (tended to decrease as the LN diameter decreased) for the diagnosis of LN metastasis by SUVmax. CONCLUSION: SiPM PET had higher diagnostic accuracy for LN metastasis of oral SCC than non-SiPM PET, even for small LN metastasis without increasing false-positives.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Carcinoma de Células Escamosas/diagnóstico por imagem , Humanos , Metástase Linfática/diagnóstico por imagem , Neoplasias Bucais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço
7.
Front Oncol ; 11: 646141, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33777807

RESUMO

OBJECTIVES: Metabolic tumor volume (MTV) on 18F-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) is a promising prognostic predictor in pancreatic ductal adenocarcinoma (PDAC). However, the optimal segmentation method and threshold value to determine MTV for PDAC are still unclear. We explored the optimal method and threshold value for the prognostic value of MTV measured on pre-treatment 18F-FDG-PET/CT. METHODS: Seventy-three patients with resected PDAC who underwent 18F FDG-PET/CT before surgical resection were enrolled. MTV values of the tumor were measured on FDG-PET/CT by the two fixed-threshold methods using threshold values as 2.0, 2.5, 3.0, and 3.5 for the absolute method and 35%, 40%, 42%, 45%, and 50% for the relative method. Receiver operating characteristic curve analysis for prediction of 1-year survival rates was conducted for determining the optimal threshold values, and we selected the optimal method and threshold value considering area under the curve. The prognostic values of each FDG-PET/CT parameter for disease-specific survival and recurrence-free survival were assessed with Kaplan-Meier method and Cox proportional hazard models. RESULTS: In receiver operating characteristic curve analysis, MTV by the fixed-absolute threshold method based on a threshold value of 3.5 (MTV3.5) performed best in our study with area under the curve 0.724, sensitivity of 65%, and specificity of 75%. In univariate and multivariate analyses, MTV3.5 was significantly associated with disease-specific and recurrence-free survival. CONCLUSIONS: MTV3.5 by absolute threshold on pre-treatment FDG-PET/CT was the best independent prognostic predictor in resectable PDAC compared with other absolute threshold values and relative threshold values.

8.
Eur J Neurol ; 28(4): 1113-1122, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33305428

RESUMO

OBJECTIVE: This study aimed to examine echolalia and its related symptoms and brain lesions in primary progressive aphasia (PPA). METHODS: Forty-five patients with PPA were included: 19 nonfluent/agrammatic variant PPA (nfvPPA), 5 semantic variant PPA, 7 logopenic variant PPA, and 14 unclassified PPA patients. We detected echolalia in unstructured conversations. An evaluation of language function and the presence of parkinsonism, grasp reflex, imitation behaviour, and disinhibition were assessed. We also measured regional cerebral blood flow (rCBF) using single-photon emission computed tomography. RESULTS: Echolalia was observed in 12 nfvPPA and 2 unclassified PPA patients. All patients showed mitigated echolalia. We compared nfvPPA patients with echolalia (echolalia group) to those without echolalia (non-echolalia group). The median age of the echolalia group was significantly lower than that of the non-echolalia group, and the echolalia group showed a significantly worse auditory comprehension performance than the non-echolalia group. In contrast, the performance of repetition tasks was not different between the two groups. The prevalence of imitation behaviour in the echolalia group was significantly higher than that in the non-echolalia group. The rCBFs in the bilateral pre-supplementary motor area and bilateral middle cingulate cortex in the echolalia group were significantly lower than those in the non-echolalia group. CONCLUSIONS: These findings suggest that echolalia is characteristic of nfvPPA patients with impaired comprehension. Reduced inhibition of the medial frontal cortex with release activity of the anterior perisylvian area account for the emergence of echolalia.


Assuntos
Afasia Primária Progressiva , Afasia , Afasia Primária Progressiva não Fluente , Afasia Primária Progressiva/diagnóstico por imagem , Afasia Primária Progressiva/epidemiologia , Ecolalia , Humanos , Idioma
9.
Artigo em Japonês | MEDLINE | ID: mdl-32814734

RESUMO

PURPOSE: This phantom study aimed to determine the optimal acquisition window size for phase-based respiratory gating in silicon photomultiplier (SiPM)-based fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) and its acquisition time in respiratory-gated imaging with the optimal window size. METHODS: Images of a moving NEMA IEC Body Phantom SetTM with hot spheres were acquired. First, the tumor volume and the maximum standardized uptake value (SUVmax) of images reconstructed using a different window size were evaluated to define the optimal window size. Second, the quality of the images reconstructed using the optimal window size and different acquisition times was evaluated using the detectability score of the 10-mm hot sphere and physical indices. RESULTS: The volume and the SUVmax of the 10-mm hot sphere were improved when the window size was narrow, and there were no significant differences among images reconstructed using a window size narrower than 20%. To reconstruct an image using the 20% window size, an acquisition time of 5 min was required to visualize the 10-mm hot sphere. CONCLUSIONS: The optimal window size for phase-based respiratory gating is 20%. Further, an acquisition time of 5 min should be taken for respiratory-gated imaging with the 20% window size on SiPM-based FDG-PET/CT.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Tomógrafos Computadorizados
10.
Front Aging Neurosci ; 12: 178, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32625080

RESUMO

Background: Decreased bone mineral density (BMD) was associated with poorer cognitive function and increased risk of Alzheimer's disease (AD). However, objective evidence for the relationship between osteoporosis and AD in humans has not been extensively described. Objectives: We aimed to evaluate the relationships between BMD and the cortical volumes of brain regions vulnerable to AD; hippocampus, parahippocampal gyrus, precuneus, posterior cingulate, and angular gyrus, using voxel-based morphometry (VBM), to investigate the association between bone loss and AD. Methods: A cohort of 149 consecutive elderly participants who complained of memory disturbance underwent high-resolution structural brain magnetic resonance imaging (MRI) and dual-energy X-ray absorptiometry (DXA). We used SPM12 software to conduct a voxel-based multiple regression analysis to examine the association between femoral neck BMD values and regional gray matter volume (rGMV) on structural T1-weighted MRI. Results: After adjusting for subject age, gender, total brain volume (TBV), and mini-mental state examination (MMSE) scores, the multiple regression analysis showed significant correlations between BMD loss and rGMV decline in the left precuneus, which is an important neural network hub vulnerable to AD. Conclusion: These data suggest that the bone and brain communicate with each other, as in "bone-brain crosstalk," and that control of BMD factors could contribute to cognitive function and help prevent AD.

11.
Clin Exp Pharmacol Physiol ; 47(3): 365-371, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31758723

RESUMO

Accelerated bone loss is closely associated with Alzheimer's disease (AD), but the relationship between bone mineral density (BMD) and imaging markers of neurodegeneration remains uncertain. We examined the effect of low bone mass (osteopenia) on regional cerebral blood flow (rCBF) in patients with AD (n = 19) and non-demented aging (n = 12). We enrolled 31 female outpatients diagnosed with osteopenia (age ≥ 65 years) who had both a single-photon emission computed tomography brain scan and dual-energy X-ray absorptiometry bone scan taken at their initial investigation. We analyzed the relationship between osteopenia (-2.5 < T-score < -1) and rCBF in 62 cortical areas measured using the stereotactic extraction estimation analysis on single-photon emission computed tomography (SPECT) (mean Z-scores). We found that the mean Z-scores of 14 cerebral subregions, most of which are often affected early in AD, were significantly lower in the AD group than the non-demented group (P < .001). The age-stratified multivariate regression analysis showed that the decreased rCBF in the left posterior cingulate cortex (PCC) was an independent predictor of osteopenia (r = -0.395; P = .005). BMD and rCBF in the left PCC were significantly correlated in the overall population (r = -0.54; P = .001), as well as the AD group (r = -0.514; P = .02). These imaging data suggest that osteopenia may contribute to neurodegeneration of a brain network hub associated with AD.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Densidade Óssea/fisiologia , Doenças Ósseas Metabólicas/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Giro do Cíngulo/irrigação sanguínea , Giro do Cíngulo/diagnóstico por imagem , Absorciometria de Fóton/tendências , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/epidemiologia , Doença de Alzheimer/fisiopatologia , Doenças Ósseas Metabólicas/epidemiologia , Doenças Ósseas Metabólicas/fisiopatologia , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/tendências , Estudos Retrospectivos
12.
Ann Nucl Med ; 33(7): 459-470, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30924048

RESUMO

PURPOSES: Subject's motion during brain PET scan degrades spatial resolution and quantification of PET images. To suppress these effects, rigid-body motion correction systems have been installed in commercial PET scanners. In this study, we systematically compare the accuracy of motion correction among 3 commercial PET scanners using a reproducible experimental acquisition protocol. METHODS: A cylindrical phantom with two 22Na point sources was placed on a customized base to enable two types of motion, 5° yaw and 15° pitch rotations. Repetitive PET scans (5 min × 5 times) were performed at rest and under 2 motion conditions using 3 clinical PET scanners: the Eminence STARGATE G/L PET/CT (STARGATE) (Shimadzu Corp.), the SET-3000 B/X PET (SET-3000) (Shimadzu Corp.), and the Biograph mMR PET/MR (mMR) (Siemens Healthcare) systems. For STARGATE and SET-3000, the Polaris Vicra (Northern Digital Inc.) optical tracking system was used for frame-by-frame motion correction. For Biograph mMR, sequential MR images were simultaneously acquired with PET and used for LOR-based motion correction. All PET images were reconstructed by FBP algorithm with 1 × 1 mm pixel size. To evaluate the accuracy of motion correction, FWHMs and spherical ROI values were analyzed. RESULTS: The percent differences (%diff) in averaged FWHMs of point sources at 4 cm off-center between motion-corrected and static images were 0.77 ± 0.16 (STARGATE), 2.4 ± 0.34 (SET-3000), and 11 ± 1.0% (mMR) for a 5° yaw and 2.3 ± 0.37 (STARGATE) and 1.1 ± 0.60 (SET-3000) for a 15° pitch respectively. The averaged %diff between ROI values of motion-corrected images and static images were less than 2.0% for all conditions. CONCLUSIONS: In this study, we proposed a reproducible experimental framework to allow the systematic validation and comparison of multiple motion tracking and correction methodologies among different PET/CT and PET/MR commercial systems. Our proposed validation platform may be useful for future studies evaluating state-of-the-art motion correction strategies in clinical PET imaging.


Assuntos
Cabeça/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Movimento , Tomografia por Emissão de Pósitrons/instrumentação , Artefatos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas
13.
Artigo em Japonês | MEDLINE | ID: mdl-28428471

RESUMO

PURPOSE: This study aimed to evaluate the statistical noise of motion-frozen (MF) image generated by gated myocardial perfusion single photon emission computed tomography (SPECT) imaging using IQ · SPECT and to determine the optimal acquisition and reconstruction parameters for MF image using IQ · SPECT. METHODS: A movement cardiac phantom and static cardiac phantom were used to acquire the MF images. The acquisition times used were different in 8 and 16 frames per R-R interval, and varying reconstruction parameters (subset and iteration) were used. We determined the %CV value, contrast, and normalized mean square error (NMSE) to evaluate the image quality. RESULTS: The %CV value for a MF image with IQ · SPECT was lower than that for a conventional non-gated myocardial perfusion SPECT (MPS) image with low energy high resolution (LEHR). With regard to the acquisition parameters, the contrast did not change when the acquisition time was increased in 8 and 16 frames per R-R interval. NMSE converged in 56 beats/view in 8 frames per R-R interval. With regard to the reconstruction parameters, the contrast and the %CV value of the anterior and septal wall converged in update 40. The minimum NMSE in subsets 1, 2, and 3 were almost similar. CONCLUSIONS: Uniformity in the MF image with IQ · SPECT was higher than that in the conventional image. The results of this MF image with IQ · SPECT study suggest that the optimal acquisition parameter should be 56 beats/view in 8 frames per R-R interval, and the optimal reconstruction parameters should be subset 3 and iteration 14.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Humanos , Movimento (Física) , Tálio
15.
PLoS One ; 11(4): e0152746, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27055151

RESUMO

BACKGROUND: Abnormal cardiac uptake of 123I-metaiodobenzylguanidine (123I-MIBG) is a diagnostic marker of Lewy body diseases (LBDs), e.g., Parkinson's disease (PD) and dementia with Lewy bodies (DLB). Planar imaging is generally used to assess cardiac sympathetic dysfunction in 123I-MIBG scintigraphy; however, its clinical utility requires further improvement. We hypothesized that the co-registration of single-photon emission tomography (SPECT) and computed tomography (CT) images would improve the diagnostic accuracy of 123I-MIBG cardiac scintigraphy for LBDs. This study sought to evaluate the effects of SPECT/CT imaging on 123I-MIBG cardiac scintigraphy for diagnosing LBDs. METHODS: We retrospectively investigated data of 54 patients (consecutive 18 patients in each PD, DLB, and idiopathic normal pressure hydrocephalus [iNPH] groups) who underwent 123I-MIBG cardiac scintigraphy (planar and SPECT/CT) because of suspected LBDs at the Tohoku University hospital from June 2012 to June 2015. We compared the diagnostic accuracies of the conventional planar 123I-MIBG method and SPECT/CT methods (manual and semi-automatic). RESULTS: In the conventional planar analysis, 123I-MIBG uptake decreased only in the DLB group compared with the iNPH group. In contrast, the SPECT/CT analysis revealed significantly lower 123I-MIBG uptake in both the PD and DLB groups compared with the iNPH group. Furthermore, a receiver operating characteristic analysis revealed that both the manual and semi-automatic SPECT/CT methods were superior to the conventional planar method in differentiating the 3 disorders. CONCLUSIONS: SPECT/CT 123I-MIBG cardiac scintigraphy can detect mild cardiac sympathetic dysfunction in LDBs. Our results suggest that the SPECT/CT technique improves diagnostic accuracy for LBDs.


Assuntos
3-Iodobenzilguanidina , Doenças do Sistema Nervoso Autônomo , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Cardiopatias , Doença por Corpos de Lewy , Doença de Parkinson , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Doenças do Sistema Nervoso Autônomo/diagnóstico por imagem , Doenças do Sistema Nervoso Autônomo/etiologia , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Feminino , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Cardiopatias/fisiopatologia , Humanos , Doença por Corpos de Lewy/complicações , Doença por Corpos de Lewy/diagnóstico por imagem , Doença por Corpos de Lewy/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/etiologia , Doença de Parkinson/fisiopatologia
16.
J Neurol Sci ; 359(1-2): 309-11, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26671133

RESUMO

BACKGROUND: Comorbidity of idiopathic normal pressure hydrocephalus and neurodegenerative diseases presents a diagnostic challenge. The aim of this study was to elucidate the clinical features of iNPH patients who are possibly comorbid with Lewy body diseases. METHODS: In this study, we retrospectively analyzed the records of consecutive 127 patients with definite idiopathic normal pressure hydrocephalus. (123)I-Metaiodobenzylguanidine myocardial scintigraphy was undertaken to 21 patients with idiopathic normal pressure hydrocephalus because of suspicion for comorbid Lewy body diseases. RESULTS: As a result, 7 of the 21 patients with idiopathic normal pressure hydrocephalus exhibited cardiac sympathetic abnormality. Idiopathic normal pressure hydrocephalus patients with cardiac sympathetic dysfunction had the constellation of clinical findings, such as younger onset, less severe urinary dysfunction, kinesie paradoxale, and cogwheel rigidity. CONCLUSIONS: Our results suggested that comorbidity of idiopathic normal pressure hydrocephalus and Lewy body diseases are not rare condition and careful screening for potentially-curative surgery is important especially in atypical cases.


Assuntos
Hidrocefalia de Pressão Normal/complicações , Doença por Corpos de Lewy/complicações , 3-Iodobenzilguanidina/farmacocinética , Idoso , Idoso de 80 Anos ou mais , Inibidores Enzimáticos/farmacocinética , Feminino , Humanos , Hidrocefalia de Pressão Normal/diagnóstico por imagem , Isótopos de Iodo/farmacocinética , Doença por Corpos de Lewy/diagnóstico por imagem , Masculino , Imagem de Perfusão do Miocárdio , Estudos Retrospectivos
17.
Ann Nucl Med ; 20(7): 493-8, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17037282

RESUMO

OBJECTIVE: Iodine-123 (123I)-labeled N-isopropyl-4-iodoamphetamine (IMP) has been used as a cerebral blood flow (CBF) tracer for single-photon emission computed tomography (SPECT). An autoradiographic (ARG) method has been developed for the quantitation of CBF by IMP and SPECT. Two IMPs (IMPA and IMPB) produced by different radiopharmaceutical companies are marketed in Japan. In the present study, whole-body distributions including brain and blood of the two IMPs were compared in the same human subjects. METHODS: Two brain SPECT studies using IMPA or IMPB were performed on separate days in six young healthy men. Whole-body scans were also obtained with a large field-of-view single-head gamma camera. One-point arterial blood sampling was performed at 10 min after injection of IMP to measure both the radioactivity concentrations of whole blood and of octanol-extracted components. RESULTS: No significant differences between the two tracers were observed in body distribution, tracer kinetics in brain, or regional distribution in brain. However, the octanol extraction fraction in blood was significantly different between the two tracers. Radiochemical purity was slightly but significantly different between the tracers. CONCLUSIONS: In the ARG method, arterial input function is determined by calibration of a standard input function with the radioactivity concentration of arterial whole blood. Because the standard input function in the ARG method was obtained using IMPA, the standard input function obtained for IMPB should be used when CBF is calculated by the ARG method with IMPB.


Assuntos
Encéfalo/efeitos dos fármacos , Radioisótopos do Iodo , Iofetamina , Compostos Radiofarmacêuticos , Adulto , Autorradiografia/métodos , Encéfalo/patologia , Humanos , Japão , Masculino , Fatores de Tempo , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...